scholarly journals Residential segregation, air temperature, and circulatory mortality: Exposure model choice matters for disparities analyses

2021 ◽  
Vol 2021 (1) ◽  
Author(s):  
Daniel Carrión ◽  
Johnathan Rush ◽  
Elena Colicino ◽  
Allan C. Just
2021 ◽  
Vol 20 (1) ◽  
Author(s):  
Mike Z. He ◽  
Vivian Do ◽  
Siliang Liu ◽  
Patrick L. Kinney ◽  
Arlene M. Fiore ◽  
...  

Abstract Background Air pollution health studies have been increasingly using prediction models for exposure assessment even in areas without monitoring stations. To date, most studies have assumed that a single exposure model is correct, but estimated effects may be sensitive to the choice of exposure model. Methods We obtained county-level daily cardiovascular (CVD) admissions from the New York (NY) Statewide Planning and Resources Cooperative System (SPARCS) and four sets of fine particulate matter (PM2.5) spatio-temporal predictions (2002–2012). We employed overdispersed Poisson models to investigate the relationship between daily PM2.5 and CVD, adjusting for potential confounders, separately for each state-wide PM2.5 dataset. Results For all PM2.5 datasets, we observed positive associations between PM2.5 and CVD. Across the modeled exposure estimates, effect estimates ranged from 0.23% (95%CI: -0.06, 0.53%) to 0.88% (95%CI: 0.68, 1.08%) per 10 µg/m3 increase in daily PM2.5. We observed the highest estimates using monitored concentrations 0.96% (95%CI: 0.62, 1.30%) for the subset of counties where these data were available. Conclusions Effect estimates varied by a factor of almost four across methods to model exposures, likely due to varying degrees of exposure measurement error. Nonetheless, we observed a consistently harmful association between PM2.5 and CVD admissions, regardless of model choice.


2018 ◽  
Vol 18 (3) ◽  
pp. 86-103

The effect of cultural distance (CD) on the entry mode choice (EMC) has been intensively studied but the empirical results are mixed. This study adopts the strategic fit perspective to examine how firms’ strategic motives and technological ownerships may influence the EMC in face of different cultural distances. Analyzing Taiwanese outward FDI cases from 2004 to 2007, this study found that firms entering the culture-distant countries would choose the wholly-owned subsidiary (WOS) mode when emphasizing more about the protection of technological competence than market expansion, or else would choose the joint-venture (JV) mode when the market expansion is prioritized.


2018 ◽  
Vol 14 (1) ◽  
pp. 44-57
Author(s):  
S. N. Shumov

The spatial analysis of distribution and quantity of Hyphantria cunea Drury, 1973 across Ukraine since 1952 till 2016 regarding the values of annual absolute temperatures of ground air is performed using the Gis-technologies. The long-term pest dissemination data (Annual reports…, 1951–1985; Surveys of the distribution of quarantine pests ..., 1986–2017) and meteorological information (Meteorological Yearbooks of air temperature the surface layer of the atmosphere in Ukraine for the period 1951-2016; Branch State of the Hydrometeorological Service at the Central Geophysical Observatory of the Ministry for Emergencies) were used in the present research. The values of boundary negative temperatures of winter diapause of Hyphantria cunea, that unable the development of species’ subsequent generation, are received. Data analyses suggests almost complete elimination of winter diapausing individuals of White American Butterfly (especially pupae) under the air temperature of −32°С. Because of arising questions on the time of action of absolute minimal air temperatures, it is necessary to ascertain the boundary negative temperatures of winter diapause for White American Butterfly. It is also necessary to perform the more detailed research of a corresponding biological material with application to the freezing technics, giving temperature up to −50°С, with the subsequent analysis of the received results by the punched-analysis.


2012 ◽  
Vol 3 (1) ◽  
pp. 63-73 ◽  
Author(s):  
I. Csáky ◽  
F. Kalmár

Abstract Nowadays the facades of newly built buildings have significant glazed surfaces. The solar gains in these buildings can produce discomfort caused by direct solar radiation on the one hand and by the higher indoor air temperature on the other hand. The amplitude of the indoor air temperature variation depends on the glazed area, orientation of the facade and heat storage capacity of the building. This paper presents the results of a simulation, which were made in the Passol Laboratory of University of Debrecen in order to define the internal temperature variation. The simulation proved that the highest amplitudes of the internal temperature are obtained for East orientation of the facade. The upper acceptable limit of the internal air temperature is exceeded for each analyzed orientation: North, South, East, West. Comparing different building structures, according to the obtained results, in case of the heavy structure more cooling hours are obtained, but the energy consumption for cooling is lower.


Sign in / Sign up

Export Citation Format

Share Document