Simulation of the internal temperature in the Passol Laboratory, University of Debrecen

2012 ◽  
Vol 3 (1) ◽  
pp. 63-73 ◽  
Author(s):  
I. Csáky ◽  
F. Kalmár

Abstract Nowadays the facades of newly built buildings have significant glazed surfaces. The solar gains in these buildings can produce discomfort caused by direct solar radiation on the one hand and by the higher indoor air temperature on the other hand. The amplitude of the indoor air temperature variation depends on the glazed area, orientation of the facade and heat storage capacity of the building. This paper presents the results of a simulation, which were made in the Passol Laboratory of University of Debrecen in order to define the internal temperature variation. The simulation proved that the highest amplitudes of the internal temperature are obtained for East orientation of the facade. The upper acceptable limit of the internal air temperature is exceeded for each analyzed orientation: North, South, East, West. Comparing different building structures, according to the obtained results, in case of the heavy structure more cooling hours are obtained, but the energy consumption for cooling is lower.

2021 ◽  
Vol 881 (1) ◽  
pp. 012017
Author(s):  
Wenny Arminda ◽  
Widi Dwi Satria ◽  
Maqbul Kamaruddin ◽  
M. Shoful Ulum

Abstract Lecture building is one of the important facilities in supporting the success of the teaching and learning process. The lecture room should be thermally comfortable and has a low risk of disease transmission. In adapting to the Covid-19 pandemic, attention to prevent disease transmission is necessary to the safety of students and lecturers while staying on campus. This study aims to propose a new concept design related to the arrangement of indoor layouts that minimize the crowds and reducing indoor air temperatures due to exposure to solar radiation on the east-west side of the building. The research was conducted by observing human movement patterns and measuring indoor air temperature and surface façade temperature adjacent to the outside environment. The results obtained that the average indoor air temperature was in the range between 28.8 - 33.2 °C, with a surface temperature on the east-west side, reaching 39.1 °C. The new design proposed the concept of one-way access by separating vertical and horizontal circulation, additional corridors, and rearranging the layout of lecture rooms to distinguish in-out access to minimize contact physical contact between building users.


2016 ◽  
Vol 820 ◽  
pp. 127-132
Author(s):  
Martin Jamnický

Current increasing of costs for the acquisition of buildings causes effort to efficiently use all the space in these construction projects. The aim is therefore to make maximum use of under-roof space, both in new buildings and in buildings already standing. Because of the trend of construction with light wooden structures wrapped in thermal isolation, it is not easy to avoid summer overheating in under-roof spaces. For this reason, we’ve focused on optimizing building structures in terms of overheating in summer, so that additional costs for air conditioning were negligible or, ideally, non-existent. It is well known from our previous experience that there is smaller rise and fluctuation of indoor air temperature in rooms with heavy mass constructions (e.g. reinforced concrete, bricks, etc.) compared to rooms with light structures.


2017 ◽  
Vol 2 (6) ◽  
Author(s):  
Yaseen Kadhim Abbas Al-Timimi ◽  
Ali Challob Khraibet

Aerosol Optical Depth (AOD) is the measure of aerosol distributed with a Column of air from earth’s surface to the top of atmosphere, in this study, temperature variation of aerosol optical depth (AOD) in Baghdad was analyzed Moderate Resolution Imaging Spectrometer (MODIS) from Terra and its relationship with temperature for the period 2003 – 2015 were examined. The highest values for mean seasonal AOD were observed in spring and summer and the maximum AOD values ranged from 0.50 to 0.58 by contrast minimum AOD values ranging from 0.30 to 0.41 were found in winter and autumn. Results of study also showed that the temperature (max., min., mean air temperature and DTR) have a strong correlation with AOD (0.82, 0.83, 0.82 and 0.65) respectively.


2021 ◽  
Vol 11 (11) ◽  
pp. 5070
Author(s):  
Xesús Prieto-Blanco ◽  
Carlos Montero-Orille

In the last few years, some advances have been made in the theoretical modelling of ion exchange processes in glass. On the one hand, the equations that describe the evolution of the cation concentration were rewritten in a more rigorous manner. This was made into two theoretical frameworks. In the first one, the self-diffusion coefficients were assumed to be constant, whereas, in the second one, a more realistic cation behaviour was considered by taking into account the so-called mixed ion effect. Along with these equations, the boundary conditions for the usual ion exchange processes from molten salts, silver and copper films and metallic cathodes were accordingly established. On the other hand, the modelling of some ion exchange processes that have attracted a great deal of attention in recent years, including glass poling, electro-diffusion of multivalent metals and the formation/dissolution of silver nanoparticles, has been addressed. In such processes, the usual approximations that are made in ion exchange modelling are not always valid. An overview of the progress made and the remaining challenges in the modelling of these unique processes is provided at the end of this review.


Author(s):  
Unai Zabala ◽  
Igor Rodriguez ◽  
José María Martínez-Otzeta ◽  
Elena Lazkano

AbstractNatural gestures are a desirable feature for a humanoid robot, as they are presumed to elicit a more comfortable interaction in people. With this aim in mind, we present in this paper a system to develop a natural talking gesture generation behavior. A Generative Adversarial Network (GAN) produces novel beat gestures from the data captured from recordings of human talking. The data is obtained without the need for any kind of wearable, as a motion capture system properly estimates the position of the limbs/joints involved in human expressive talking behavior. After testing in a Pepper robot, it is shown that the system is able to generate natural gestures during large talking periods without becoming repetitive. This approach is computationally more demanding than previous work, therefore a comparison is made in order to evaluate the improvements. This comparison is made by calculating some common measures about the end effectors’ trajectories (jerk and path lengths) and complemented by the Fréchet Gesture Distance (FGD) that aims to measure the fidelity of the generated gestures with respect to the provided ones. Results show that the described system is able to learn natural gestures just by observation and improves the one developed with a simpler motion capture system. The quantitative results are sustained by questionnaire based human evaluation.


2021 ◽  
Author(s):  
Jan Kočí ◽  
Laura Ré Luvisotto ◽  
Jiří Maděra

2021 ◽  
pp. 030157422098054
Author(s):  
Renu Datta

Introduction: The upper lateral incisor is the most commonly missing tooth in the anterior segment. It leads to esthetic and functional imbalance for the patients. The ideal solution is the one that is most conservative and which fulfills the functional and esthetic needs of the concerned individual. Canine substitution is evolving to be the treatment of choice in most of the cases, because of its various advantages. These are special cases that need more time and effort from the clinicians due to space discrepancy in the upper and lower arches, along with the presentation of individual malocclusion. Aims and Objectives: Malocclusion occurring due to missing laterals is more complex, needing more time and effort from the clinicians because of space discrepancy, esthetic compromise, and individual presentation of the malocclusion. An attempt has been made in this article to review, evaluate, and tabulate the important factors for the convenience of clinicians. Method: All articles related to canine substitution were searched in the electronic database PubMed, and the important factors influencing the decision were reviewed. After careful evaluation, the checklist was evolved. Result: The malocclusions in which canine substitution is the treatment of choice are indicated in the tabular form for the convenience of clinicians. Specific treatment-planning considerations and biomechanics that can lead to an efficient and long-lasting result are also discussed. Conclusion: The need of the hour is an evidence-based approach, along with a well-designed prospective randomized control trial to understand the importance of each factor influencing these cases. Until that time, giving the available information in a simplified way can be a quality approach to these cases.


Atmosphere ◽  
2020 ◽  
Vol 11 (12) ◽  
pp. 1377
Author(s):  
Weifang Shi ◽  
Nan Wang ◽  
Aixuan Xin ◽  
Linglan Liu ◽  
Jiaqi Hou ◽  
...  

Mitigating high air temperatures and heat waves is vital for decreasing air pollution and protecting public health. To improve understanding of microscale urban air temperature variation, this paper performed measurements of air temperature and relative humidity in a field of Wuhan City in the afternoon of hot summer days, and used path analysis and genetic support vector regression (SVR) to quantify the independent influences of land cover and humidity on air temperature variation. The path analysis shows that most effect of the land cover is mediated through relative humidity difference, more than four times as much as the direct effect, and that the direct effect of relative humidity difference is nearly six times that of land cover, even larger than the total effect of the land cover. The SVR simulation illustrates that land cover and relative humidity independently contribute 16.3% and 83.7%, on average, to the rise of the air temperature over the land without vegetation in the study site. An alternative strategy of increasing the humidity artificially is proposed to reduce high air temperatures in urban areas. The study would provide scientific support for the regulation of the microclimate and the mitigation of the high air temperature in urban areas.