0617 A Fundamental Study on heat removal by natural convection for a waste storage cooling system

2007 ◽  
Vol 2007.3 (0) ◽  
pp. 155-156
Author(s):  
Hiroshi IKEDA ◽  
Daichi SUZUKI ◽  
Kotaro NAKADA ◽  
Chikako IWAKI ◽  
Yoshikazu MASAKI ◽  
...  
2019 ◽  
Vol 21 (2) ◽  
pp. 87
Author(s):  
Rahayu Kusumastuti ◽  
Sriyono Sriyono ◽  
Mulya Juarsa ◽  
Hendro Tjahjono ◽  
I. D. Irianto ◽  
...  

Reaktor Daya Eksperimental (RDE) is an experimental power reactor based on HTGR technology that implements inherent safety system. Its safety systems are in compliance with “defense in depth” philosophy. RDE is also equipped with reactor cavity cooling system (RCCS) used to remove the heat transferred from the reactor vessel to the containment structure. The RCCS is designed to fulfil this role by maintain the reactor vessel under the maximum allowable temperature during normal operation and protecting the containment structure in the event of failure of all passive cooling systems. The performance and reliability of the RCCS, therefore, are considered as critical factors in determining maximum design power level related to heat removal. RCCS for RDE will use a novel shape to efficiently remove the heat released from the RPV through thermal radiation and natural convection. This paper discusses the calculation of RCCS thermal analysis during accident. The RPV temperature must be maintained below 65ºC. The accident is assumed that there is no electricity from diesel generator supplied to the blower. The methodology used is based on the calculation of mathematical model of the RCCS in the passive mode. The heat is released through cavity by natural convection, in which the RCCS is capable to withdraw the heat at the rate of 50.54 kW per hour.Keywords: Passive safety, RCCS, RDE, Thermal analysis


Author(s):  
Hui Wang ◽  
Qiang Guo ◽  
Qiaoyan Chen

Passive Containment Cooling System (PCS) is one of the most important passive safety features in AP1000 nuclear power plant. Numerical Simulation of PCS without falling film was conducted using CFD method in this paper to investigate heat transfer performance of PCS. The results indicate that: at the time of 72 hours after break accident, there is no water in passive containment cooling water storage tank (PCCWST), PCS cannot completely remove reactor core decay heat to environment just with the effect of natural convection and thermal radiation; mass flow rate of natural convection and PCS heat removal power increase with the increase of the outside surface temperature of steel containment, but the increasing amplitude of the former is smaller than the latter significantly, and the fraction of thermal radiation in the PCS heat removal power is the smallest when the outside surface temperature of steel containment is 80 °C; mass flow rate of natural convection and PCS heat removal power decrease with the increase of environmental temperature, while the fraction of thermal radiation in the whole heat removal power becomes bigger with the increase of environmental temperature.


2021 ◽  
Vol 11 (7) ◽  
pp. 3236
Author(s):  
Ji Hyeok Kim ◽  
Joon Ahn

In a field test of a hybrid desiccant cooling system (HDCS) linked to a gas engine cogeneration system (the latter system is hereafter referred to as the combined heat and power (CHP) system), in the cooling operation mode, the exhaust heat remained and the latent heat removal was insufficient. In this study, the performance of an HDCS was simulated at a humidity ratio of 10 g/kg in conditioned spaces and for an increasing dehumidification capacity of the desiccant rotor. Simulation models of the HDCS linked to the CHP system were based on a transient system simulation tool (TRNSYS). Furthermore, TRNBuild (the TRNSYS Building Model) was used to simulate the three-dimensional structure of cooling spaces and solar lighting conditions. According to the simulation results, when the desiccant capacity increased, the thermal comfort conditions in all three conditioned spaces were sufficiently good. The higher the ambient temperature, the higher the evaporative cooling performance was. The variation in the regeneration heat with the outdoor conditions was the most dominant factor that determined the coefficient of performance (COP). Therefore, the COP was higher under high temperature and dry conditions, resulting in less regeneration heat being required. According to the prediction results, when the dehumidification capacity is sufficiently increased for using more exhaust heat, the overall efficiency of the CHP can be increased while ensuring suitable thermal comfort conditions in the cooling space.


Author(s):  
Li Yabing ◽  
Zhang Han ◽  
Xiao Jianjun

A dynamic film model is developed in the parallel CFD code GASFLOW-MPI for passive containment cooling system (PCCS) utilized in nuclear power plant like AP1000 and CAP1400. GASFLOW-MPI is a widely validated parallel CDF code and has been applied to containment thermal hydraulics safety analysis for different types of reactors. The essential issue for PCCS is the heat removal capability. Research shows that film evaporation contributes most to the heat removal capability for PCCS. In this study, the film evaporation model is validated with separate effect test conducted on the EFFE facility by Pisa University. The test region is a rectangle gap with 0.1m width, 2m length, and 0.6m depth. The water film flowing from the top of the gap is heated by a heating plate with constant temperature and cooled by countercurrent air flow at the same time. The test region model is built and analyzed, through which the total thermal power and evaporation rate are obtained to compare with experimental data. Numerical result shows good agreement with the experimental data. Besides, the influence of air velocity, wall temperature and gap widths are discussed in our study. Result shows that, the film evaporation has a positive correlation with air velocity, wall temperature and gap width. This study can be fundamental for our further numerical study on PCCS.


Author(s):  
Shoji Takada ◽  
Shunki Yanagi ◽  
Kazuhiko Iigaki ◽  
Masanori Shinohara ◽  
Daisuke Tochio ◽  
...  

HTTR is a helium gas cooled graphite-moderated HTGR with the rated power 30 MWt and the maximum reactor outlet coolant temperature 950°C. The vessel cooling system (VCS), which is composed of thermal reflector plates, cooling panel composed of fins connected between adjacent water cooling tubes, removes decay heat from reactor core by heat transfer of thermal radiation, conduction and natural convection in case of loss of forced cooling (LOFC). The metallic supports are embedded in the biological shielding concrete to support the fins of VCS. To verify the inherent safety features of HTGR, the LOFC test is planned by using HTTR with the VCS inactive from an initial reactor power of 9 MWt under the condition of LOFC while the reactor shut-down system disabled. In this test, the temperature distribution in the biological shielding concrete is prospected locally higher around the support because of thermal conduction in the support. A 2-dimensional symmetrical model was improved to simulate the heat transfer to the concrete through the VCS support in addition to the heat transfer thermal radiation and natural convection. The model simulated the water cooling tubes setting horizontally at the same pitch with actual configuration. The numerical results were verified in comparison with the measured data acquired from the test, in which the RPV was heated up to around 110 °C without nuclear heating with the VCS inactive, to show that the temperature is locally high but kept sufficiently low around the support in the concrete due to sufficient thermal conductivity to the cold temperature region.


2015 ◽  
Vol 719-720 ◽  
pp. 46-49 ◽  
Author(s):  
Ginka Ranga Janardhana ◽  
Mani Senthil Kumar ◽  
B. Dhanasekar

The plasma cutting technology has been emerged as a developing technology which finds tremendous potential in fabrication and metal cutting industries. Thus for the cutting operation, the electrode inside the plasma torch plays a vital role for the plasma arc generation. The temperature of the arc is very high and at the electrode is around 3500°C. The cutting torch requires proper cooling system in order to prevent the electrode from quick wear due to the existence of high thermal gradient. The presented work aimed to study the impact of three coolants propylene glycol, ethylene glycol and de-ionized water flow over the electrode life. The experimental setups were arranged to study the heat transfer capabilities of the three coolants for different flow values and aimed to achieve the optimal flow rates for the efficient heat removal. The electrode life test trials were conducted to measure the electrode life for the flow values of three coolants in the temperature rise test. The optimal flow rates arrived from temperature rise test and the electrode life measured from life test are compared for the three coolant cases considered.


Sign in / Sign up

Export Citation Format

Share Document