Validation of Film Evaporation Model in GASFLOW-MPI

Author(s):  
Li Yabing ◽  
Zhang Han ◽  
Xiao Jianjun

A dynamic film model is developed in the parallel CFD code GASFLOW-MPI for passive containment cooling system (PCCS) utilized in nuclear power plant like AP1000 and CAP1400. GASFLOW-MPI is a widely validated parallel CDF code and has been applied to containment thermal hydraulics safety analysis for different types of reactors. The essential issue for PCCS is the heat removal capability. Research shows that film evaporation contributes most to the heat removal capability for PCCS. In this study, the film evaporation model is validated with separate effect test conducted on the EFFE facility by Pisa University. The test region is a rectangle gap with 0.1m width, 2m length, and 0.6m depth. The water film flowing from the top of the gap is heated by a heating plate with constant temperature and cooled by countercurrent air flow at the same time. The test region model is built and analyzed, through which the total thermal power and evaporation rate are obtained to compare with experimental data. Numerical result shows good agreement with the experimental data. Besides, the influence of air velocity, wall temperature and gap widths are discussed in our study. Result shows that, the film evaporation has a positive correlation with air velocity, wall temperature and gap width. This study can be fundamental for our further numerical study on PCCS.

Author(s):  
Manoj Siva ◽  
Arvind Pattamatta ◽  
Sarit Kumar Das

A common assumption in basic heat exchanger design theory is that fluid is distributed uniformly at the inlet of the exchanger on each fluid side and throughout the core. However in reality, uniform flow distribution is never achieved in a heat exchanger and is referred to as flow maldistribution. Flow maldistribution is generally well understood for the macrochannel system. But it is still unclear whether the assumptions underlying the flow distribution in conventional macrochannel heat exchangers hold good for microchannel system. In this regard, extensive numerical simulations are carried out in a ‘U’ type parallel micro-channel system in order to study flow and heat transfer maldistribution and validated with in-house experimental data. A detailed parametric analysis is carried out to characterize flow maldistribution in a microchannel system and to study the effect of geometrical factors such as number of channels, n, Area of cross section of the channel Ac, manifold cross section area Ap, and flow parameter such as Reynolds number, Re, on the pressure and temperature distribution. In order to minimize the variation in pressure and to reduce temperature hot spots in the microchannel, a Response surface based surrogate approximation (RSA) and a gradient based search algorithm are used to arrive at the best configuration of microchannel cooling system. A three level factorial design involving three parameters namely Ac/Ap, Re, n are considered. The results from the optimization indicate that the case of n = 5, Ac/Ap = 0.12, and Re = 100 is the best possible configuration to alleviate flow maldistribution and hotspot formation in microchannel cooling system.


Author(s):  
V. Manoj Siva ◽  
Arvind Pattamatta ◽  
Sarit Kumar Das

A common assumption in basic heat exchanger design theory is that fluid is distributed uniformly at the inlet of the exchanger on each fluid side and throughout the core. However, in reality, uniform flow distribution is never achieved in a heat exchanger and is referred to as flow maldistribution. Flow maldistribution is generally well understood for the macrochannel system. But it is still unclear whether the assumptions underlying the flow distribution in conventional macrochannel heat exchangers hold good for microchannel system. In this regard, extensive numerical simulations are carried out in a “U” type parallel microchannel system in order to study flow and heat transfer maldistribution and validated with in-house experimental data. A detailed parametric analysis is carried out to characterize flow maldistribution in a microchannel system and to study the effect of geometrical factors such as number of channels, n, Area of cross section of the channel Ac, manifold cross section area Ap, and flow parameter such as Reynolds number, Re, on the pressure and temperature distribution. In order to minimize the variation in pressure and to reduce temperature hot spots in the microchannel, a response surface based surrogate approximation and a gradient based search algorithm are used to arrive at the best configuration of microchannel cooling system. A three level factorial design involving three parameters namely Ac/Ap, Re, n are considered. The results from the optimization indicate that the case of n = 7, Ac/Ap = 0.69, and Re = 100 is the best possible configuration to alleviate flow maldistribution and hotspot formation in microchannel cooling system.


2017 ◽  
Vol 79 (7-3) ◽  
Author(s):  
Amirah M. Sahar ◽  
A. I. M. Shaiful

Parallel microchannels have been widely used in cooling of compact electronic equipment due to large contact area with liquid and availability of large mass of fluid to carry away heat. However, understanding of flow distribution for microchannel parallel system is still unclear and there still lack of studies give a clear pictures to understand the complex flow features which cause the flow maldistribution. Generally, the geometrical structure of the manifold and micro channels play an important role in flow distribution between micro channels, which might affects the heat and mass transfer efficiency, even the performance of micro exchangers. A practical design of exchanger basically involves the selection of an optimized solution, keeping an optimal balance between gain in heat transfer and pressure drop penalty. A parallel microchannels configurations consisting inlet and outlet rectangular manifold were simulated to study flow distribution among the channels were investigated numerically by using Ansys Fluent 14.5. The numerical results was validated using existing experimental data and showed a similar trend with values 1% higher than experimental data. The influence of inlet/outlet manifold area and inlet/outlet arrangement on flow distribution in channels were carried out in this study. Based on the predicted flow non-uniformity value, 𝜙, Z- type flow arrangement exhibits higher value of 𝜙, which is 8%, followed by U-type, 2.6% and the I-type, 2.49%. Thus, a better uniformity of velocity and temperature distributions can be achieved in I-shape flow arrangement. The behavior of the flow distributions inside channels is due to the vortices that occurred at manifold. Besides comparing the pressure drop for case 1(D1) and case 2(D2), it is worth to mention that, as the area of inlet and outlet manifold decrease by 50%, the pressure drop is increasing about 5%. However, the inlet/outlet area of manifold on velocity and fluid temperature distributions was insignificant.


2021 ◽  
Vol 9 ◽  
Author(s):  
Po Hu ◽  
Zhen Hu

In the passive containment cooling system of AP1000, the condensed water is expected to flow down on the inner surface of the steel wall of the containment, and recover to the in-containment refueling water storage tank (IRWST), therefore, to maintain the long-term coolability of the passive residual heat removal system. However, there are attached bulging plates on the inner surface for various engineering needs, such as supporting, and the impingement of condensed water film on these bulging plates can reduce the amount of the recovered water. In this article, a 3-D Eulerian wall film model in FLUENT was used to study a series of flow behaviors when a water film impinged on the bulging plate on a plane surface. The loss ratio of falling film impinging on attached plates of different sizes under different flow rates were calculated and in good agreement with the experiment results. Four stages of the film behavior during the impingement were identified and analyzed; in addition, the influences of the bulging height of attached plate and flow rate were studied. And a correlation between the loss ratio of impinging water film, the bulging height of the attached plate, and the Weber number was obtained.


1992 ◽  
Vol 27 (2) ◽  
pp. 221-238 ◽  
Author(s):  
W. Ripl

Abstract Densely populated urban areas, which have developed over the last century, depend heavily on centralized water supply, sewage treatment plants, and hydroelectric or thermal power generation with vast demand of cooling water. Considerable areas have been drained or sealed, and the short-circuited water cycle has been distorted. Large rivers have been converted to shipping canals with the permanent risk of accidental pollution. Technical means such as sewage treatment, air filters, emission control and lake and soil restoration measures have contributed to correct the environmental damage. However, a balance sheet for irreversible matter losses (mainly base cation charges) from the urbanized areas and the surrounding landscape into the sea shows ever-increasing trends. These losses are destabilizing the ecosystems. In this paper, management of the water cycle in urban areas, together with the coupled matter cycles, is discussed. Particular reference is given to Metropolitan Berlin, with a network of shipping canals, which move biologically treated waste, containing base cations and nutrients to the surrounding rural areas. This could create manageable productive wetlands and re-establish soil fertility. At the same time, the natural cooling system close to the urban areas will be improved by providing more areas with permanent vegetation. In addition, reduction of the present large oscillations of the groundwater table, resulting from groundwater pumping and its recharge with less polluted surface water, is contemplated. The widely used shoreline infiltration of the Havel River should then be eliminated and the severe damage of the littoral vegetation in large sections of the Havel River system be avoided.


Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3634
Author(s):  
Grzegorz Czerwiński ◽  
Jerzy Wołoszyn

With the increasing trend toward the miniaturization of electronic devices, the issue of heat dissipation becomes essential. The use of phase changes in a two-phase closed thermosyphon (TPCT) enables a significant reduction in the heat generated even at high temperatures. In this paper, we propose a modification of the evaporation–condensation model implemented in ANSYS Fluent. The modification was to manipulate the value of the mass transfer time relaxation parameter for evaporation and condensation. The developed model in the form of a UDF script allowed the introduction of additional source equations, and the obtained solution is compared with the results available in the literature. The variable value of the mass transfer time relaxation parameter during condensation rc depending on the density of the liquid and vapour phase was taken into account in the calculations. However, compared to previous numerical studies, more accurate modelling of the phase change phenomenon of the medium in the thermosyphon was possible by adopting a mass transfer time relaxation parameter during evaporation re = 1. The assumption of ten-fold higher values resulted in overestimated temperature values in all sections of the thermosyphon. Hence, the coefficient re should be selected individually depending on the case under study. A too large value may cause difficulties in obtaining the convergence of solutions, which, in the case of numerical grids with many elements (especially three-dimensional), significantly increases the computation time.


2021 ◽  
Vol 11 (7) ◽  
pp. 3236
Author(s):  
Ji Hyeok Kim ◽  
Joon Ahn

In a field test of a hybrid desiccant cooling system (HDCS) linked to a gas engine cogeneration system (the latter system is hereafter referred to as the combined heat and power (CHP) system), in the cooling operation mode, the exhaust heat remained and the latent heat removal was insufficient. In this study, the performance of an HDCS was simulated at a humidity ratio of 10 g/kg in conditioned spaces and for an increasing dehumidification capacity of the desiccant rotor. Simulation models of the HDCS linked to the CHP system were based on a transient system simulation tool (TRNSYS). Furthermore, TRNBuild (the TRNSYS Building Model) was used to simulate the three-dimensional structure of cooling spaces and solar lighting conditions. According to the simulation results, when the desiccant capacity increased, the thermal comfort conditions in all three conditioned spaces were sufficiently good. The higher the ambient temperature, the higher the evaporative cooling performance was. The variation in the regeneration heat with the outdoor conditions was the most dominant factor that determined the coefficient of performance (COP). Therefore, the COP was higher under high temperature and dry conditions, resulting in less regeneration heat being required. According to the prediction results, when the dehumidification capacity is sufficiently increased for using more exhaust heat, the overall efficiency of the CHP can be increased while ensuring suitable thermal comfort conditions in the cooling space.


Sign in / Sign up

Export Citation Format

Share Document