Time-Resolved Constant-Energy Synchronous Phosphorimetry

1988 ◽  
Vol 42 (6) ◽  
pp. 1112-1117 ◽  
Author(s):  
Javier J. Laserna ◽  
Michael A. Mignardi ◽  
Ray Von Wandruska ◽  
James D. Winefordner

Constant-energy synchronous scanning has been combined with time resolution in order to increase the spectral selectivity in low-temperature phosphorimetry. The technique is called Time-Resolved Constant-Energy Synchronous Phosphorimetry (TRCESP). The personal computer-controlled flashlamp phosphorimeter consisted of a conventional spectrophosphorimeter with computer control of the scanning of the excitation and emission spectrometers. Temporal features such as the repetition rate, source pulse width, delay time between termination of the source pulse and the gate opening, and detector gate width were under various forms of electronic control. A discussion of the spectral resolution resulting from synchronous scanning and temporal resolution from pulsing the source and gating the detector is given. Several mixtures of phosphors are evaluated with respect to the effect of spatial resolution, temporal resolution, and combination of the two resolution approaches upon both sensitivity and selectivity measurements.

Author(s):  
R. J. Lee ◽  
J. S. Walker

Electron microscopy (EM), with the advent of computer control and image analysis techniques, is rapidly evolving from an interpretative science into a quantitative technique. Electron microscopy is potentially of value in two general aspects of environmental health: exposure and diagnosis.In diagnosis, electron microscopy is essentially an extension of optical microscopy. The goal is to characterize cellular changes induced by external agents. The external agent could be any foreign material, chemicals, or even stress. The use of electron microscopy as a diagnostic tool is well- developed, but computer-controlled electron microscopy (CCEM) has had only limited impact, mainly because it is fairly new and many institutions lack the resources to acquire the capability. In addition, major contributions to diagnosis will come from CCEM only when image analysis (IA) and processing algorithms are developed which allow the morphological and textural changes recognized by experienced medical practioners to be quantified. The application of IA techniques to compare cellular structure is still in a primitive state.


Author(s):  
Marc J.C. de Jong ◽  
P. Emile S.J. Asselbergs ◽  
Max T. Otten

A new step forward in Transmission Electron Microscopy has been made with the introduction of the CompuStage on the CM-series TEMs: CM120, CM200, CM200 FEG and CM300. This new goniometer has motorization on five axes (X, Y, Z, α, β), all under full computer control by a dedicated microprocessor that is in communication with the main CM processor. Positions on all five axes are read out directly - not via a system counting motor revolutions - thereby providing a high degree of accuracy. The CompuStage enters the octagonal block around the specimen through a single port, allowing the specimen stage to float freely in the vacuum between the objective-lens pole pieces, thereby improving vibration stability and freeing up one access port. Improvements in the mechanical design ensure higher stability with regard to vibration and drift. During stage movement the holder O-ring no longer slides, providing higher drift stability and positioning accuracy as well as better vacuum.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Abhik Datta ◽  
Kian Fong Ng ◽  
Deepan Balakrishnan ◽  
Melissa Ding ◽  
See Wee Chee ◽  
...  

AbstractFast, direct electron detectors have significantly improved the spatio-temporal resolution of electron microscopy movies. Preserving both spatial and temporal resolution in extended observations, however, requires storing prohibitively large amounts of data. Here, we describe an efficient and flexible data reduction and compression scheme (ReCoDe) that retains both spatial and temporal resolution by preserving individual electron events. Running ReCoDe on a workstation we demonstrate on-the-fly reduction and compression of raw data streaming off a detector at 3 GB/s, for hours of uninterrupted data collection. The output was 100-fold smaller than the raw data and saved directly onto network-attached storage drives over a 10 GbE connection. We discuss calibration techniques that support electron detection and counting (e.g., estimate electron backscattering rates, false positive rates, and data compressibility), and novel data analysis methods enabled by ReCoDe (e.g., recalibration of data post acquisition, and accurate estimation of coincidence loss).


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
C. Callenberg ◽  
A. Lyons ◽  
D. den Brok ◽  
A. Fatima ◽  
A. Turpin ◽  
...  

AbstractImaging across both the full transverse spatial and temporal dimensions of a scene with high precision in all three coordinates is key to applications ranging from LIDAR to fluorescence lifetime imaging. However, compromises that sacrifice, for example, spatial resolution at the expense of temporal resolution are often required, in particular when the full 3-dimensional data cube is required in short acquisition times. We introduce a sensor fusion approach that combines data having low-spatial resolution but high temporal precision gathered with a single-photon-avalanche-diode (SPAD) array with data that has high spatial but no temporal resolution, such as that acquired with a standard CMOS camera. Our method, based on blurring the image on the SPAD array and computational sensor fusion, reconstructs time-resolved images at significantly higher spatial resolution than the SPAD input, upsampling numerical data by a factor $$12 \times 12$$ 12 × 12 , and demonstrating up to $$4 \times 4$$ 4 × 4 upsampling of experimental data. We demonstrate the technique for both LIDAR applications and FLIM of fluorescent cancer cells. This technique paves the way to high spatial resolution SPAD imaging or, equivalently, FLIM imaging with conventional microscopes at frame rates accelerated by more than an order of magnitude.


2017 ◽  
Vol 114 (39) ◽  
pp. 10473-10478 ◽  
Author(s):  
Peter Kok ◽  
Pim Mostert ◽  
Floris P. de Lange

Perception can be described as a process of inference, integrating bottom-up sensory inputs and top-down expectations. However, it is unclear how this process is neurally implemented. It has been proposed that expectations lead to prestimulus baseline increases in sensory neurons tuned to the expected stimulus, which in turn, affect the processing of subsequent stimuli. Recent fMRI studies have revealed stimulus-specific patterns of activation in sensory cortex as a result of expectation, but this method lacks the temporal resolution necessary to distinguish pre- from poststimulus processes. Here, we combined human magnetoencephalography (MEG) with multivariate decoding techniques to probe the representational content of neural signals in a time-resolved manner. We observed a representation of expected stimuli in the neural signal shortly before they were presented, showing that expectations indeed induce a preactivation of stimulus templates. The strength of these prestimulus expectation templates correlated with participants’ behavioral improvement when the expected feature was task-relevant. These results suggest a mechanism for how predictive perception can be neurally implemented.


Sensors ◽  
2020 ◽  
Vol 20 (23) ◽  
pp. 6831
Author(s):  
Muhammad Ali Abbas ◽  
Luuk van Dijk ◽  
Khalil Eslami Jahromi ◽  
Mohammadreza Nematollahi ◽  
Frans J. M. Harren ◽  
...  

Conventional mechanical Fourier Transform Spectrometers (FTS) can simultaneously measure absorption and dispersion spectra of gas-phase samples. However, they usually need very long measurement times to achieve time-resolved spectra with a good spectral and temporal resolution. Here, we present a mid-infrared dual-comb-based FTS in an asymmetric configuration, providing broadband absorption and dispersion spectra with a spectral resolution of 5 GHz (0.18 nm at a wavelength of 3333 nm), a temporal resolution of 20 μs, a total wavelength coverage over 300 cm−1 and a total measurement time of ~70 s. We used the dual-comb spectrometer to monitor the reaction dynamics of methane and ethane in an electrical plasma discharge. We observed ethane/methane formation as a recombination reaction of hydrocarbon radicals in the discharge in various static and dynamic conditions. The results demonstrate a new analytical approach for measuring fast molecular absorption and dispersion changes and monitoring the fast dynamics of chemical reactions over a broad wavelength range, which can be interesting for chemical kinetic research, particularly for the combustion and plasma analysis community.


1972 ◽  
Vol 16 ◽  
pp. 344-353 ◽  
Author(s):  
Carol J. Kelly ◽  
E. Eichen

AbstractThe system to be described includes hardware and software for the on-line computer control of the X-ray diffraction measurement of residual stress. This determination involves accurately measuring the angles at which a back-reflection line is diffracted, first by diffracting planes parallel to the sample surface, and then by planes at an angle (ψ) to the sample surface. The residual stress is calculated from the difference in the two measured diffraetion angles. The procedure executed by the computer consists of locating the peaks, selecting three angles for collection of X-ray counts, correcting the measured counts, fitting the equi-angular intensity measurements to a three-point parabola, calculating the peak angles, calculating the residual stress from the measured angles and typing a report. This automation has eliminated the tedium of the manual X-ray data accumulation and of the residual stress calculation. The online control has also permitted improvements in the technique not practicable with the manually performed measurement of residual stress.


2015 ◽  
Vol 8 (7) ◽  
pp. 2901-2907 ◽  
Author(s):  
Z. Wang ◽  
D. Liu ◽  
Y. Wang ◽  
Z. Wang ◽  
G. Shi

Abstract. A strong diurnal variation of aerosol has been observed in many heavily polluted regions in China. This variation could affect the direct aerosol radiative forcing (DARF) evaluation if the daily averaged value is used as normal rather than the time-resolved values. To quantify the effect of using the daily averaged DARF, 196 days of high temporal resolution ground-based data collected in SKYNET Hefei site during the period from 2007 to 2013 is used to perform an assessment. We demonstrate that strong diurnal changes of heavy aerosol loading have an impact on the 24-h averaged DARF when daily averaged optical properties are used to retrieve this quantity. The DARF errors varying from −7.6 to 15.6 W m−2 absolutely and from 0.1 to 28.5 % relatively were found between the calculations using daily average aerosol properties, and those using time-resolved aerosol observations. These errors increase with increasing daily aerosol optical depth (AOD) and decreasing daily single-scattering albedo (SSA), indicating that the high temporal resolution DARF data set should be used in the model instead of the normal daily-averaged one, especially under heavy aerosol loading conditions for regional campaign studies. We also found that statistical errors (0.3 W m−2 absolutely and 11.8 % relatively) will be less, which means that the effect of using the daily averaged DARF can be weakened by using a long-term observational data set.


Sign in / Sign up

Export Citation Format

Share Document