Correlation analysis of durability and concrete cover thickness of concrete structure

2010 ◽  
Vol 1 (2) ◽  
pp. 207 ◽  
Author(s):  
Jun Wei ◽  
Pei Li ◽  
Xiwu Zhou ◽  
Keqiang Zhang
2020 ◽  
Vol 1 (1) ◽  
pp. 01-06
Author(s):  
Sevar Neamat ◽  
Mahmood Shamsborhan

The reinforcing spacers are commonly prepared from cementitious material, plastic or metals. These spacers are prepared to provide the reinforcing steel with ensuring that the requested concrete cover thickness is attained to guard surrounded steel from corrosion. Also, they pretend a vital role in the concrete structure performance. The toughness of reinforced concrete buildings remains extremely reliant on the features of the protection of concrete to be strong with thickness. A disappointment in finding cover thickness is considered the main impact on early deterioration within the steel, whichever in chance is a chief weaken method in reinforced concrete constructions. The specified study offerings a review study on the investigation of the advantages and disadvantages of six factors in various types concerning the ground rebar spacers studies. As a result, different types of ground rebar spacers have been compared and the new rebar spacer has been designed mixed of concrete_ plastic material


2014 ◽  
Vol 926-930 ◽  
pp. 623-626
Author(s):  
Ke Feng Zhang

For concrete structure durability increasingly highlight of problem, focus description has chlorine ion on concrete structure of erosion mechanism, and invaded model and effects factors, derivation out integrated consider concrete of chlorine ion combines capacity, and chlorine ion proliferation coefficient of time dependence, and concrete structure micro-defects effects and the mixed coagulation s performance of practical proliferation equation, established has for forecast concrete using life of chlorine ion proliferation theory model, made intends built structure in chlorine ion environment Xia durability design thought and design method, Perfected design theory of durability of concrete and carbonation model design based on Carbonation depth of concrete during the period, compared with the concrete cover thickness, for engineering design and revision of the specification reference.


2011 ◽  
Vol 255-260 ◽  
pp. 757-761 ◽  
Author(s):  
Roger Zou ◽  
Ahmad Shayan ◽  
Frank Collins

Corrosion of reinforcement can significantly affect the bond strength between the steel bar and the surrounding concrete thus greatly reducing the load bearing capacity of the concrete structure. In this paper, a simple analytical model is proposed to evaluate the maximum bond strength of corroded concrete with varying rebar diameters and concrete cover thickness. Predicted results compared well with experimental test data.


2010 ◽  
Vol 168-170 ◽  
pp. 1042-1045
Author(s):  
Ying Li Gao ◽  
Bao Guo Ma

Tunnel lining concrete segment is the most critical and important structural member of shield tunneling. This investigation designed and produced high-performance composite concrete segment (HCCS). Some key indexes that affect the properties of segment were tested, such as impermeability, volume stability, mechanical property, etc. The results indicated that the impermeability of HCCS concrete cover was excellent and the chloride diffusion coefficient decreased one order of magnitude compared to that of the ordinary segment concrete cover, while the service-life of HCCS increased more than ten-fold. The volume stability of HCCS concrete cover and concrete structure layer were good and the better compatibility in the volume deformation of the whole structure was shown. Furthermore, the mechanical properties of concrete cover and concrete structure layer met the project requirement perfectly, ensuring the higher durability and longer service-life of HCCS effectively.


2020 ◽  
Vol 2020 ◽  
pp. 1-15
Author(s):  
Yubin Tian ◽  
Junran Liu ◽  
Hengheng Xiao ◽  
Yi Zhang ◽  
Qingcheng Mo ◽  
...  

This paper presents the results of an experimental research designed to investigate the combined effects of corrosion rate, concrete cover thickness, and stirrup spacing on the bond performance between reinforcement and concrete of reinforced concrete (RC) specimens. The RC specimens were immersed into sodium chloride solution to eliminate the passivation film on reinforcement. Then, an accelerated corrosion method was applied to corrode reinforcement embedded in concrete specimens. Pullout test was carried out to establish empirical formulas for ultimate slip and ultimate bond strength of RC specimens with three different corrosion rates, different concrete cover thicknesses, and different stirrup spacings. In addition, the bond-slip relation model was developed to predict and evaluate the bond performance of RC specimens. Finally, the ultrasonic technology was used to detect the damage of RC specimens, and the corresponding nonlinear coefficient β was proposed to characterize the damage degree of RC specimens. The susceptibility of β on the damage of specimens was compared with that of ultrasonic velocity, indicating β was more appropriate to evaluate the damage of RC specimens.


2018 ◽  
Vol 11 (4) ◽  
pp. 856-875 ◽  
Author(s):  
A. M. GIL ◽  
B. FERNANDES ◽  
F. L. BOLINA ◽  
B. F. TUTIKIAN

Abstract Among the processes that involve the degradation of concrete structures subject to the high temperatures of a fire there is the spalling phenomenon. Its mechanisms are related to the thermal stress of the materials dilatations and pore pressure the process of vaporization of water during heating. The factors that influences in its occurrence are related to concrete properties, structural member characteristics or the exposure conditions, and their parameters are not clearly known yet. This paper aimed to study the influence of three concrete mixtures, four coating thicknesses and two bars diameters of longitudinal reinforcement in the spalling phenomena exposed to ISO 834 fire curve. The characterization of concrete were performed either of the axial compression strength tests, water absorption by capillary and mercury intrusion porosimetry, besides the fire resistance tests in real-scale specimens. It was concluded that the diameter of the bar does not have influence, while the mixture and the concrete cover thickness does. More spalling was recorded for the columns with thicker concrete cover and concrete compressive strength at 61,9 MPa, and although higher strength concrete have less permeability, this characteristic can be balanced with the higher tensile strength of this type of concrete.


2013 ◽  
Vol 671-674 ◽  
pp. 1672-1675
Author(s):  
Yan Hui Li ◽  
Yang Yang Zhang ◽  
Jing Cun Wei ◽  
Yun Feng Wu

Through calculation and analysis on routine examination and neutralization of reinforced concrete chimney, the service life of concrete structure was evaluated only considering neutralization of concrete single factor. The results show that the neutralization of the reinforced concrete chimney was serious than that of other similar projects. The initiation time of reinforcement corrosion were 19.3a, cracking time of concrete cover were 27.35a.


Sign in / Sign up

Export Citation Format

Share Document