scholarly journals Long-Term Weather Data Measurements From A Danish Climate Station And The Weather’s Influence On The Thermal Performance Of Solar Collectors

2015 ◽  
Vol 23 (2) ◽  
pp. 23-29
Author(s):  
Lukáš Skalík

Abstract A weather data evaluation from a climate station in Lyngby, Denmark, was carried out. Twenty years of measurements show that the increase in global radiation was almost 3.5 kWh/m2 per year, corresponding to a growth of the yearly global radiation of 7 % for the last 20 years. The global radiation variation between the least sunny year to the sunniest year was 20%. The increase in diffuse radiation was 1.9 kWh/m2 per year, corresponding to 20 years’ growth of up to 7 %. The annual diffuse radiation of nearly 19 % varied from the least cloudy year to the cloudiest year. A small increase was measured for the ambient air temperature. The measurements showed a yearly increase of 0.04 K per year. The average yearly ambient air temperature variation from the coldest to the warmest year was 3.1 K. According to the seasonal growth of the parameters measured, the ambient air temperature and diffuse radiation increased the most in the summer period, while the global radiation significantly increased in the spring months. The calculations of the solar collector's thermal performance in Lyngby showed that the energy output was mostly dependent on beam radiation. The ambient air temperature did not have a high influence on the thermal performance of the solar collectors compared to the influence of the total solar radiation.

Author(s):  
Saeed Moaveni ◽  
Patrick A. Tebbe ◽  
Louis Schwartzkopf ◽  
Joseph Dobmeier ◽  
Joseph Gehrke ◽  
...  

In this paper, we will present a numerical model for estimating the thermal performance of unglazed transpired solar collectors located on the Breck School campus in Minneapolis, Minnesota. The solar collectors are installed adjacent to the southeast facing wall of a field house. The collectors preheat the intake air before entering the primary heating unit. The solar collector consists of 8 separate panels (absorber plates). Four fans are connected to the plenum that is created by the absorber plates and the adjoining field house wall. All fresh air for the field house is provided by the solar collectors before being filtered and heated by four, independent two stage natural gas fired heaters. Moreover, the following data were collected onsite using a data acquisition system: indoor field house space temperature, ambient air temperature, wind speed, wind direction, the plenum exit air temperature, the absorber plate temperature, and the air temperatures inside the plenum. The energy balance equations for the collector, the adjacent building wall, and the plenum are formulated. The numerical model is used to predict the air temperature rise inside the plenum, recaptured heat loss from the adjoining building wall, energy savings, and the efficiency of the collectors. The results of the numerical model are then compared to the results obtained from the onsite measurements; which are in good agreement. The model presented in this paper is simple yet accurate enough for architects and engineers to use it with ease to predict the thermal performance of a collector.


Author(s):  
Robert Brandon ◽  
Bryan Halliday ◽  
John S. Hoffman

The significant reduction in power output of small gas turbines at high ambient temperatures places the technology at a significant disadvantage compared with reciprocating engines. On site power applications in many jurisdictions are experiencing high power costs during summer peak times. A variable speed industrial fan combined with an evaporative cooler has been constructed and operated in the CETC laboratory in Ottawa, Canada to supply supercharged inlet air to a microturbine rated at 70 kW at ISO conditions. The supercharging system can raise the inlet air pressure by 10.5 kPa (42” wc). A mapping of the turbine performance has been done as a function of boost pressure, relative humidity and ambient air temperature. A net power increase has been observed from 57 kW to 70 kW at an ambient air temperature of 33°C (91°F) and RH of 60%, a 23% increase. Supercharging at lower temperatures yields lower net power increases since the microturbine generator rating is the limiting factor; for example an 11% increase in net power was observed at an inlet air temperature of 11°C (52°F) and RH of 60%. Supercharging was shown to decrease net fuel-to-electricity efficiency of this recuperated turbine by about 3%, at an air temperature of 33°C (91°F). An economic analysis using published power prices and weather data from Toronto explores the business case of using supercharging, with the best economies likely for multiple units or larger microturbines, such as 250 kW units. The objective of the project was to demonstrate the concept leading to a field trial in Toronto or in Calgary where the altitude offers a further benefit to the inlet air supercharging concept. Work is underway to design a control system suitable for field deployment for the concept.


2018 ◽  
Vol 8 (11) ◽  
pp. 2214 ◽  
Author(s):  
Seokjae Lee ◽  
Sangwoo Park ◽  
Minkyu Kang ◽  
Hangseok Choi

The energy slab is a novel type of horizontal Ground Heat Exchanger (GHEX), where heat exchange pipes are encased in building slab structures. The thermal performance of energy slabs is usually inferior to the conventional closed-loop vertical GHEX because its installation depth is relatively shallow and therefore affected by ambient air temperature. In this paper, heat exchange pipes were made of not only conventional high-density polyethylene (HDPE), but also stainless steel (STS), which is expected to enhance the thermal performance of the energy slabs. In addition to a floor slab, a side wall slab was also used as a component of energy slabs to maximize the use of geothermal energy that can be generated from the underground space. Moreover, a thermal insulation layer in the energy slabs was considered in order to reduce thermal interference induced by ambient air temperature. Consequently, two different field-scale energy slabs (i.e., floor-type and wall-type energy slabs) were constructed in a test bed, and two types of heat exchange pipes (i.e., STS pipe and HDPE pipes) were installed in each energy slab. A series of thermal response tests (TRTs) and thermal performance tests (TPTs) were conducted to evaluate the heat exchange performance of the constructed energy slabs. Use of the STS heat exchange pipe enhanced the thermal performance of energy slabs. Additionally, the wall-type energy slab had a similar thermal performance to the floor-type energy slab, which infers the applicability of the additional use of the wall-type energy slab. Note that if an energy slab is not thermally cut off from the building’s interior space with the aid of thermal insulation layers, heat exchange within the energy slabs should be significantly influenced by fluctuations in ambient temperature.


1982 ◽  
Vol 17 (1) ◽  
pp. 135-148
Author(s):  
P.T. Wong ◽  
D.S. Mavinic

Abstract The treatability of a municipal leachate (BOD5 = 8090 mg/L) was investigated, by aerobic biostabilization, at a nutrient loading of BOD5:N:P of 100:3.2:1.1. The first stage effluents were subsequently polished by lime-magnesium coagulation. The ranges of ambient air temperature and sludge age studied were 5° to 25°C and 5 to 20 days, respectively. In the biostabilization phase, a BOD5:N:P loading of 100:3.2:1.1 was found to be “adequate” for treatment. Organic and metal removals in the first stage units were excellent. Under all conditions investigated, except for the two units close to washout conditions (5-day sludge age units at 5° and 10°C), BOD5 and COD removals of at least 99.4 and 96.4 percent, respectively, were achieved. Similarly, removal rates for most of the metals monitored were greater than 90 percent. In general, the removal of residual contaminants was not enhanced significantly by the addition of magnesium in the lime-magnesium polishing step.


Molecules ◽  
2021 ◽  
Vol 26 (11) ◽  
pp. 3398
Author(s):  
Yi Long ◽  
Kun Liu ◽  
Yongli Zhang ◽  
Wenzhe Li

Inorganic cesium lead halide perovskites, as alternative light absorbers for organic–inorganic hybrid perovskite solar cells, have attracted more and more attention due to their superb thermal stability for photovoltaic applications. However, the humid air instability of CsPbI2Br perovskite solar cells (PSCs) hinders their further development. The optoelectronic properties of CsPbI2Br films are closely related to the quality of films, so preparing high-quality perovskite films is crucial for fabricating high-performance PSCs. For the first time, we demonstrate that the regulation of ambient temperature of the dry air in the glovebox is able to control the growth of CsPbI2Br crystals and further optimize the morphology of CsPbI2Br film. Through controlling the ambient air temperature assisted crystallization, high-quality CsPbI2Br films are obtained, with advantages such as larger crystalline grains, negligible crystal boundaries, absence of pinholes, lower defect density, and faster carrier mobility. Accordingly, the PSCs based on as-prepared CsPbI2Br film achieve a power conversion efficiency of 15.5% (the maximum stabilized power output of 15.02%). Moreover, the optimized CsPbI2Br films show excellent robustness against moisture and oxygen and maintain the photovoltaic dark phase after 3 h aging in an air atmosphere at room temperature and 35% relative humidity (R.H.). In comparison, the pristine films are completely converted to the yellow phase in 1.5 h.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Younes Bahammou ◽  
Mounir Kouhila ◽  
Haytem Moussaoui ◽  
Hamza Lamsyehe ◽  
Zakaria Tagnamas ◽  
...  

PurposeThis work aims to study the hydrothermal behavior of mortar cement toward certain environmental factors (ambient air temperature and air velocity) based on its drying kinetics data. The objective is to provide a better understanding and controlling the stability of mortar structures, which integrate the sorption phenomenon, drying process, air pressure and intrinsic characteristics. This leads to predict the comportment of mortar structures in relation with main environmental factors and minimize the risk of cracking mortar structures at an early age.Design/methodology/approachThermokinetic study was carried out in natural and forced convection solar drying at three temperatures 20, 30 and 40°C and three air velocities (1, 3 and 5 m.s-1). The empirical and semiempirical models tested successfully describe the drying kinetics of mortar. These models simulate the drying process of water absorbed by capillarity, which is the most common humidity transfer mechanism in building materials and contain parameters with physical significance, which integrate the effect of several environmental factors and intrinsic characteristics of mortar structures.FindingsThe models simulate the drying process of water absorbed by capillarity, which is the most common humidity transfer mechanism in building materials and contain parameters with physical significance, which integrate the effect of several environmental factors and intrinsic characteristics of mortar structures. The average activation energy obtained expressed the temperature effect on the mortar diffusivity. The drying constant and the diffusion coefficient can be used to predict the influence of these environmental factors on the drying behavior of various building materials and therefore on their durability.Originality/valueEvaluation of the effect of several environmental factors and intrinsic characteristics of mortar structures on their durability.


10.1289/ehp92 ◽  
2016 ◽  
Vol 124 (12) ◽  
pp. 1882-1890 ◽  
Author(s):  
Maria C. Mirabelli ◽  
Ambarish Vaidyanathan ◽  
W. Dana Flanders ◽  
Xiaoting Qin ◽  
Paul Garbe

1958 ◽  
Vol 38 (2) ◽  
pp. 148-159 ◽  
Author(s):  
M. A. MacDonald ◽  
J. M. Bell

This report presents effects of low temperatures on the feed consumption and efficiency of milk production of six mature, lactating, Holstein-Friesian cows that were confined in stanchions for three fortnightly experimental periods during which ambient temperatures measured in degree-hours per day (d-h/day) ranged from 110 to 1152 and daily minimum ambient air temperature (DMAAT) varied from 0° to 38°F. Applying results obtained, it was calculated that as temperatures decreased, i.e., d-h/day increased from 100 to 1200 and DMAAT decreased from 40° to 0°F, average daily intakes of total dry matter, hay, and gross and digestible Calories increased approximately 6.4 lb., 5.3 lb., 13 Therms and 9 Therms, respectively. Each of these increases was statistically significant at the 1 per cent level. Reductions in temperature also decreased gross and net caloric efficiencies of milk production approximately 10 and 8.5 per cent, respectively. These decreases were significant at the 2 per cent level. No correlation was evident between crude protein utilization and temperature.Results indicated that thermal stress was not overcome adequately by supplementary hay intake alone and that appetite stimulation by low temperatures had a carry-over effect continuing at least 24 hours. For continued efficient milk production during winters where low ambient temperatures are prevalent these results suggest it is necessary to provide some form of building insulation, ambient heat and/or provide a high energy supplement to otherwise adequate production rations.


Author(s):  
Henriks Putāns ◽  
Viktorija Zagorska ◽  
Imants Ziemelis ◽  
Zanis Jesko

A flat plate solar collector with cell polycarbonate absorber and transparent cover has been made and its experimental investigation carried out. The collector consists of a wooden box, into which, a layer of heat insulation with a mirror film and 4 mm thick cell polycarbonate sheet, as the absorber, are placed. The coherence between collector’s efficiency, heat carrier and ambient air temperature, as well as intensity of the solar radiation and heat power in the experimental investigation has been obtained. During the experimental examination the maximum temperature of the heat carrier reached 80˚C at the intensity of solar radiation about 0.8 kW/m2 and ambient air temperature around 32˚C. The efficiency of the collector reached 33-60%, depending on the intensity of solar radiation and surrounding air temperature.