scholarly journals Internal structure of rock glaciers in Altai (The case of talus rock glacier in Dzhelo River Valley)

2019 ◽  
Vol 9 (4) ◽  
pp. 729-731
Author(s):  
G. S. Dyakova ◽  
A. A. Goreyavcheva ◽  
V. V. Potapov ◽  
A. N. Shein ◽  
D. S. Lobachev ◽  
...  

In 2019, a comprehensive study of the internal structure of the talus rock glacier in the Dzhelo River valley was carried out (North-Chuya Range). The identification of the internal structure was performed using electrical resistivity tomography and GPR sounding. In order to compare the internal structure of the rock glacier with its surface morphology, we carried out aerial photography and constructed a digital terrain model. The study revealed that the depth of the rock-ice core varies from 2.5-3 m to 10 m, and the thickness ranges from 7 m to 30 m. The consolidation cores of the rock-ice material are confined to inter-ridge depressions in the rock glacier body. The potential volume of a rock-ice core is 800 thousand m3, which is 53% of the rock glacier total volume, the ice volume in the rock-ice core can be as much as 400 thousand m3.

Author(s):  
R. Antoine ◽  
C. Fauchard ◽  
V. Guilbert ◽  
B. Beaucamp ◽  
C. Ledun ◽  
...  

Abstract. We present geophysical and remote sensing measurements on a flood dike, in the framework of the Polder2C’s Interreg European Project (https://polder2cs.eu/). Electrical Resistivity Tomography (ERT) and Ground Penetrating Radar (GPR) profiles have been performed alongside and across the dike. The geophysical measurements are then combined with a Digital Terrain Model (DTM) caarried out with a RGB visible camera on board an Unmanned Aerial Vehicle (UAV). Integrated 3D results enrich data interpretation and form the basis for Polder2C’s future experiments.


2020 ◽  
Author(s):  
Nora Krebs ◽  
Anne Voigtländer ◽  
Matthias Bücker ◽  
Andreas Hördt ◽  
Ruben Schroeckh ◽  
...  

<p>Geophysical methods provide a powerful tool to understand the internal structure of active rock glaciers. We applied Electrical Resistivity Tomography (ERT) to a rock glacier at an elevation of 5500 m a.s.l. in the semi-arid Nyainqêntanglha mountain range on the Tibetan plateau, China.  The investigations comprised three transects across the rock glacier and its catchment, each spanning over a distance of 296 m up to 396 m, equipped with 75 up to 100 electrodes respectively. Our measurements were successful in revealing internal structures of the rock glacier, but were also accompanied by challenges.</p><p>We successfully detected first-order permafrost structures, such as a shallow about 4 m thick active layer of low electrical resistivity values that was underlain by potentially ice rich zones of high resistivity. Further high-resistivity zones were found and interpreted as dense bed rock of adjacent slopes that undergird the loose rock glacier debris.</p><p>Challenges, we faced in the application of ERT, were mainly posed by the morphology and internal structure of the rock glacier itself. Coarse debris created a rough surface that prevented a uniform setup with accurate 4 m spacing. The presence of loosely nested blocks of pebble size up to boulders with large interspaces resulted in high contact resistances. The consequent low injection current densities and possible noisy voltage readings downgraded part of the data, causing low data density and resolution. Coupling was partly improved by attaching salt-watered sponges to the electrodes and adding more conductive fine-grained materials to the electrodes. The detected high resistivity ice layer impeded deep penetration of electrical currents, which caused that the lower limit of the permanently frozen zone could not be defined.</p><p>Despite these challenges, the captured ERT profiles are an indispensable contribution to the sparse field data on the internal structure of rock glaciers on the Tibetan plateau. Our results contribute to a better understanding of the prospective evolution of rock glaciers in dry, high mountain ranges under a changing climate.</p>


Author(s):  
Marcin Brach ◽  
Jarosław Chormański

Abstract Terrestrial Laser Scanning (TLS) as a detection method of the natural river valley microtopography - case study of the Upper Biebrza. This paper concerns the use of Terrestrial Laser Scanning (TLS) methods and the Geographic Information Systems (GIS) analysis to determine microtopography of a natural river valley, case study of the upper Biebrza valley. The scientific problem analyzed in this paper is a morphology of the selected segments of the valley covered by sedge ecosystems which in natural stage form a characteristic tussocks from their root systems. In order to capture the microtopography it was necessary to remove vegetation from the selected areas, and then, for a five typical location, registration of its structure using the laser scanner. As a result the point cloud was generated for each of the selected area and after GIS analysis the microtopography was obtained in form of digital terrain model (DTM). The DTM of each area represents valleys microstructure possible to obtain by use of TLS (TLS DTM), is usually not registered by the Airborne Laser Scanning (ALS), and is the main reason of inaccuracy of the DTM obtained based on ALS. The resulting TLS DTM has been processed by various filtering methods to lower the noise and fill the voids from blocking the laser beam by a tussocks. Finally, this allowed to determine the spatial structure of each measurement field.


Forests ◽  
2021 ◽  
Vol 12 (3) ◽  
pp. 265
Author(s):  
Mihnea Cățeanu ◽  
Arcadie Ciubotaru

Laser scanning via LiDAR is a powerful technique for collecting data necessary for Digital Terrain Model (DTM) generation, even in densely forested areas. LiDAR observations located at the ground level can be separated from the initial point cloud and used as input for the generation of a Digital Terrain Model (DTM) via interpolation. This paper proposes a quantitative analysis of the accuracy of DTMs (and derived slope maps) obtained from LiDAR data and is focused on conditions common to most forestry activities (rough, steep terrain with forest cover). Three interpolation algorithms were tested: Inverse Distance Weighted (IDW), Natural Neighbour (NN) and Thin-Plate Spline (TPS). Research was mainly focused on the issue of point data density. To analyze its impact on the quality of ground surface modelling, the density of the filtered data set was artificially lowered (from 0.89 to 0.09 points/m2) by randomly removing point observations in 10% increments. This provides a comprehensive method of evaluating the impact of LiDAR ground point density on DTM accuracy. While the reduction of point density leads to a less accurate DTM in all cases (as expected), the exact pattern varies by algorithm. The accuracy of the LiDAR-derived DTMs is relatively good even when LiDAR sampling density is reduced to 0.40–0.50 points/m2 (50–60 % of the initial point density), as long as a suitable interpolation algorithm is used (as IDW proved to be less resilient to density reductions below approximately 0.60 points/m2). In the case of slope estimation, the pattern is relatively similar, except the difference in accuracy between IDW and the other two algorithms is even more pronounced than in the case of DTM accuracy. Based on this research, we conclude that LiDAR is an adequate method for collecting morphological data necessary for modelling the ground surface, even when the sampling density is significantly reduced.


2020 ◽  
Vol 12 (1) ◽  
pp. 1185-1199
Author(s):  
Mirosław Kamiński

AbstractThe research area is located on the boundary between two Paleozoic structural units: the Radom–Kraśnik Block and the Mazovian–Lublin Basin in the southeastern Poland. The tectonic structures are separated by the Ursynów–Kazimierz Dolny fault zone. The digital terrain model obtained by the ALS (Airborne Laser Scanning) method was used. Classification and filtration of an elevation point cloud were performed. Then, from the elevation points representing only surfaces, a digital terrain model was generated. The model was used to visually interpret the course of topolineaments and their automatic extraction from DTM. Two topolineament systems, trending NE–SW and NW–SE, were interpreted. Using the kernel density algorithm, topolineament density models were generated. Using the Empirical Bayesian Kriging, a thickness model of quaternary deposits was generated. A relationship was observed between the course of topolineaments and the distribution and thickness of Quaternary formations. The topolineaments were compared with fault directions marked on tectonic maps of the Paleozoic and Mesozoic. Data validation showed consistency between topolineaments and tectonic faults. The obtained results are encouraging for further research.


2021 ◽  
Vol 10 (2) ◽  
pp. 91
Author(s):  
Triantafyllia-Maria Perivolioti ◽  
Antonios Mouratidis ◽  
Dimitrios Terzopoulos ◽  
Panagiotis Kalaitzis ◽  
Dimitrios Ampatzidis ◽  
...  

Covering an area of approximately 97 km2 and with a maximum depth of 58 m, Lake Trichonis is the largest and one of the deepest natural lakes in Greece. As such, it constitutes an important ecosystem and freshwater reserve at the regional scale, whose qualitative and quantitative properties ought to be monitored. Depth is a crucial parameter, as it is involved in both qualitative and quantitative monitoring aspects. Thus, the availability of a bathymetric model and a reliable DTM (Digital Terrain Model) of such an inland water body is imperative for almost any systematic observation scenario or ad hoc measurement endeavor. In this context, the purpose of this study is to produce a DTM from the only official cartographic source of relevant information available (dating back approximately 70 years) and evaluate its performance against new, independent, high-accuracy hydroacoustic recordings. The validation procedure involves the use of echosoundings coupled with GPS, and is followed by the production of a bathymetric model for the assessment of the discrepancies between the DTM and the measurements, along with the relevant morphometric analysis. Both the production and validation of the DTM are conducted in a GIS environment. The results indicate substantial discrepancies between the old DTM and contemporary acoustic data. A significant overall deviation of 3.39 ± 5.26 m in absolute bottom elevation differences and 0.00 ± 7.26 m in relative difference residuals (0.00 ± 2.11 m after 2nd polynomial model corrector surface fit) of the 2019 bathymetric dataset with respect to the ~1950 lake DTM and overall morphometry appear to be associated with a combination of tectonics, subsidence and karstic phenomena in the area. These observations could prove useful for the tectonics, geodynamics and seismicity with respect to the broader Corinth Rift region, as well as for environmental management and technical interventions in and around the lake. This dictates the necessity for new, extensive bathymetric measurements in order to produce an updated DTM of Lake Trichonis, reflecting current conditions and tailored to contemporary accuracy standards and state-of-the-art research in various disciplines in and around the lake.


Drones ◽  
2021 ◽  
Vol 5 (1) ◽  
pp. 20
Author(s):  
Joseph P. Hupy ◽  
Cyril O. Wilson

Soil erosion monitoring is a pivotal exercise at macro through micro landscape levels, which directly informs environmental management at diverse spatial and temporal scales. The monitoring of soil erosion can be an arduous task when completed through ground-based surveys and there are uncertainties associated with the use of large-scale medium resolution image-based digital elevation models for estimating erosion rates. LiDAR derived elevation models have proven effective in modeling erosion, but such data proves costly to obtain, process, and analyze. The proliferation of images and other geospatial datasets generated by unmanned aerial systems (UAS) is increasingly able to reveal additional nuances that traditional geospatial datasets were not able to obtain due to the former’s higher spatial resolution. This study evaluated the efficacy of a UAS derived digital terrain model (DTM) to estimate surface flow and sediment loading in a fluvial aggregate excavation operation in Waukesha County, Wisconsin. A nested scale distributed hydrologic flow and sediment loading model was constructed for the UAS point cloud derived DTM. To evaluate the effectiveness of flow and sediment loading generated by the UAS point cloud derived DTM, a LiDAR derived DTM was used for comparison in consonance with several statistical measures of model efficiency. Results demonstrate that the UAS derived DTM can be used in modeling flow and sediment erosion estimation across space in the absence of a LiDAR-based derived DTM.


Sign in / Sign up

Export Citation Format

Share Document