In-situ Microscopic Study of Cu Intragranular Electromigration

2005 ◽  
Vol 907 ◽  
Author(s):  
Kuan-Chia Chen ◽  
Chien-Neng Liao ◽  
Wen-Wei Wu ◽  
Lih-Juann Chen

AbstractElectromigration (EM) in unpassivated copper lines at room temperature has been investigated in ultra-high vacuum by in-situ transmission electron microscopy (TEM). The electric current induced atomic migration in a (211)-oriented Cu grain has been successfully recorded in real-time video. The atomic image of the (211) grain was found to vanish directionally when applying an electric current density of 2 × 106 A/cm2 through the Cu line. The results suggested that the combination of {111} planes and <110> directions to be the easiest EM path in crystalline copper. By performing selective area diffraction (SAD) analysis on a single Cu grain with (111) crystal orientation, some unusual electron diffraction patterns appeared after passing an electric current through the Cu line. It is believed that the EM-induced Cu twinning may be held responsible for the unique diffraction patterns

2001 ◽  
Vol 7 (S2) ◽  
pp. 1274-1275
Author(s):  
Guang-Wen Zhou ◽  
Mridula D.Bharadwaj ◽  
Judith C.Yang

In the study of metal oxidation, there is a wide gap between information provided by surface science methods and that provided by bulk oxidation studies. The former have mostly examined the adsorption of up to ∽1 monolayer (ML) of oxygen on the metal surface, where as both low and high temperature bulk oxidation studies have mainly focused on the growth of an oxide layer at the later stages of oxidation. Hence, we are visualizing the initial oxidation stages of a model metal system by in situ ultra-high vacuum (UHV) transmission electron microscopy (TEM), where the surfaces are atomically clean, in order to gain new understanding of these ambiguous stages of oxidation. We have previously studied the growth of Cu2O islands during initial oxidation of Cu(100) film. We are presently investigating the initial stages of Cu(110) oxidation, from 10−4 Torr O2 to atmospheric pressures and temperature range from room temperature to 700 °C.


Author(s):  
C. Meneau D'Anterroches

Silicides are studied in electronic engineering for their good metallic properties. Among them the group of rare earth silicides shows particular properties. Indeed, some of them, including ErSi2, crystallize in the AIB2 structure although they do not have the exact stoechiometry, their composition being about 1.7. Thus the physical properties and the influence of vacancies on the structure are studied.The film studied in this work was obtained by in-situ annealing, in ultra high vacuum, of a Si-Er film codeposited on a clean Si (111) substrate. Details are given by F. Arnaud d'Avitaya et al. The epitaxial relationship is (111 )Si//(001 )ErSi2 and (112)Si//(100)ErSi2. According to this orientation the lattice mismatch at the interface is - 1.3 %. The films were analysed using high resolution transmission electron microscopy : they are continuous when annealed at 900°C, and show some extra-spots in their diffraction patterns depending on the zone axis. Extra spots were observed along the {111} (3) and {112} zone axes, but not along {110} (4), We will focus in this paper on the {112}Si or {120}ErSi2 zone axis, the corresponding electron diffraction pattern being in Fig. 1.


1994 ◽  
Vol 332 ◽  
Author(s):  
M.R. Scheinfein ◽  
S.D. Healy ◽  
K.R. Heim ◽  
Z.J. Yang ◽  
J.S. Drucker ◽  
...  

ABSTRACTWe have used nanometer spatial resolution secondary electron and Auger electron imaging in an ultra-high vacuum scanning transmission electron microscope to characterize microstructure in ultrathin films of Fe/Cu(100) grown at room temperature and Fe/CaF2/Si(111) grown at room temperature and 150 C. Thin film microstructure was correlated in situ with magnetic properties by using the surface magneto-optic Kerr effect.


Author(s):  
Xianghong Tong ◽  
Oliver Pohland ◽  
J. Murray Gibson

The nucleation and initial stage of Pd2Si crystals on Si(111) surface is studied in situ using an Ultra-High Vacuum (UHV) Transmission Electron Microscope (TEM). A modified JEOL 200CX TEM is used for the study. The Si(111) sample is prepared by chemical thinning and is cleaned inside the UHV chamber with base pressure of 1x10−9 τ. A Pd film of 20 Å thick is deposited on to the Si(111) sample in situ using a built-in mini evaporator. This room temperature deposited Pd film is thermally annealed subsequently to form Pd2Si crystals. Surface sensitive dark field imaging is used for the study to reveal the effect of surface and interface steps.The initial growth of the Pd2Si has three stages: nucleation, growth of the nuclei and coalescence of the nuclei. Our experiments shows that the nucleation of the Pd2Si crystal occurs randomly and almost instantaneously on the terraces upon thermal annealing or electron irradiation.


Author(s):  
D. Loretto ◽  
J. M. Gibson ◽  
S. M. Yalisove

The silicides CoSi2 and NiSi2 are both metallic with the fee flourite structure and lattice constants which are close to silicon (1.2% and 0.6% smaller at room temperature respectively) Consequently epitaxial cobalt and nickel disilicide can be grown on silicon. If these layers are formed by ultra high vacuum (UHV) deposition (also known as molecular beam epitaxy or MBE) their thickness can be controlled to within a few monolayers. Such ultrathin metal/silicon systems have many potential applications: for example electronic devices based on ballistic transport. They also provide a model system to study the properties of heterointerfaces. In this work we will discuss results obtained using in situ and ex situ transmission electron microscopy (TEM).In situ TEM is suited to the study of MBE growth for several reasons. It offers high spatial resolution and the ability to penetrate many monolayers of material. This is in contrast to the techniques which are usually employed for in situ measurements in MBE, for example low energy electron diffraction (LEED) and reflection high energy electron diffraction (RHEED), which are both sensitive to only a few monolayers at the surface.


Author(s):  
Michael T. Marshall ◽  
Xianghong Tong ◽  
J. Murray Gibson

We have modified a JEOL 2000EX Transmission Electron Microscope (TEM) to allow in-situ ultra-high vacuum (UHV) surface science experiments as well as transmission electron diffraction and imaging. Our goal is to support research in the areas of in-situ film growth, oxidation, and etching on semiconducter surfaces and, hence, gain fundamental insight of the structural components involved with these processes. The large volume chamber needed for such experiments limits the resolution to about 30 Å, primarily due to electron optics. Figure 1 shows the standard JEOL 2000EX TEM. The UHV chamber in figure 2 replaces the specimen area of the TEM, as shown in figure 3. The chamber is outfitted with Low Energy Electron Diffraction (LEED), Auger Electron Spectroscopy (AES), Residual Gas Analyzer (RGA), gas dosing, and evaporation sources. Reflection Electron Microscopy (REM) is also possible. This instrument is referred to as SHEBA (Surface High-energy Electron Beam Apparatus).The UHV chamber measures 800 mm in diameter and 400 mm in height. JEOL provided adapter flanges for the column.


1990 ◽  
Vol 181 ◽  
Author(s):  
J. M. Gibson ◽  
D. Loretto ◽  
D. Cherns

ABSTRACTWe have studied the formation of metal silicides in-situ in an ultra-high vacuum transmission electron microscope. Metals were deposited on in-situ cleaned, reconstructed silicon surfaces and annealed. For the metals Ni and Co, we find that the phase sequence in ultra-thin films is different from that seen in ≈1000 Å thick films, and attribute this to the high surface-to-volume ratio. In general reactions occur at room temperature, to form an epitaxial phase if possible. We report preliminary new results on the formation of Pd2Si.


2007 ◽  
Vol 1026 ◽  
Author(s):  
Li Sun ◽  
John E. Pearson ◽  
Judith C. Yang

AbstractThe nucleation and growth of Cu2O and NiO islands due to oxidation of Cu-24%Ni(001) films were monitored at various temperatures by in situ ultra-high vacuum (UHV) transmission electron microscopy (TEM). In remarkable contrast to our previous observations of Cu and Cu-Au oxidation, irregular-shaped polycrystalline oxide islands were observed to form with respect to the Cu-Ni alloy film, and an unusual second oxide nucleation stage was noted. Similar to Cu oxidation, the cross-sectional area growth rate of the oxide island is linear indicating oxygen surface diffusion is the primary mechanism of oxide growth.


1997 ◽  
Vol 3 (S2) ◽  
pp. 583-584
Author(s):  
J. C. Yang ◽  
M. Yeadon ◽  
B. Kolasa ◽  
J. M. Gibson

We studied the beginning oxidation stage of a model metal system by in-situ transmission electron microscopy (TEM) in order to gain insights into the initial kinetics of oxidation. In-situ TEM experiments can distinguish between nucleation and growth since individual oxide islands are imaged. We chose to investigate Cu, since it is a simple face-centered cubic metal. Also, Cu is a highly promising metal interconnect material because of its low resistivity and good electromigration properties as compared to Al.Single crystal -1000Å 99.999% purity copper films were grown on irradiated NaCl in an UHV e-beam evaporator system. The free-standing copper film was placed on a specially designed holder, which permits resistive heating of the sample. The microscope used for this experiment is a modified ultra-high vacuum, with base pressure of 10−9 torr, JEOL200CX, operated at l00kV. To remove the native oxide formed during exposure in air, the Cu film was annealed at ∼350°C


1998 ◽  
Vol 4 (S2) ◽  
pp. 608-609
Author(s):  
Ruud M. Tromp

To obtain a full and detailed understanding of the spatiotemporal dynamics of surface processes such as epitaxial growth, strain relaxation, phase transformations and phase transitions, chemisorption and etching, in situ real-time observations have proven to be invaluable. The development of two experimental techniques, i.e. Low Energy Electron Microscopy (LEEM) typically operating at electron energies below 10 eV, and Ultra-High-Vacuum Transmission Electron Microscopy (UHV-TEM) at several 100 keV, has made such in situ studies routinely possible. In many cases, the videodata obtained from such experiments are amenable to detailed, quantitative analysis, yielding statistical, kinetic and thermodynamic information that cannot be obtained in any other way.I will discuss recent experimental developments, including the design and construction of a new and improved LEEM instrument. Figure 1 shows a schematic diagram of this new machine. There are several features that distinguishes this design from most other LEEMs. One is the use of a 90 degree deflection magnetic prism array,