scholarly journals Adhesive bonding of resin cements to cast titanium with adhesive primers

2012 ◽  
Vol 23 (3) ◽  
pp. 218-222 ◽  
Author(s):  
Marina Di Francescantonio ◽  
Marcelo Tavares de Oliveira ◽  
Luiz Gustavo Dias Daroz ◽  
Guilherme Elias Pessanha Henriques ◽  
Marcelo Giannini

The purpose of this study was to evaluate the effects of adhesive primer applications on the bond strength of resin cements to cast titanium. Four adhesive primers - Metaltite, Metal Primer II, Alloy Primer and Ceramic Primer - and their respective resin cements - Bistite II DC, Link Max, Panavia F 2.0, RelyX Unicem and RelyX ARC - were tested. Cast plates were prepared from titanium ingots (n=6 specimens/cement) and had their surfaces airborne-particle abraded with Al2O3 (50 μ m). Three resin cement cylinders were built on each bonded titanium surface, using a cylindrical translucent tubing mold and were subjected to micro-shear testing. Data were analyzed statistically by two-way ANOVA and Tukey's post-hoc test (α=0.05). The application of Metal Primer II and Ceramic Primer resulted in significant higher bond strength for Link Max and RelyX Unicem resin cements, respectively, than nonuse of adhesive primers. Panavia F 2.0 and RelyX ARC yielded high bond strength means with or without adhesive primers. The use of adhesive primers might increase the bond strength to cast titanium depending on the resin cement used.

2013 ◽  
Vol 14 (4) ◽  
pp. 675-680
Author(s):  
Khalil Aleisa

ABSTRACT Statement of the problem Post retention is crucial factor in restoration survival. Posts are commonly failed due to loss of retention. It is unknown which luting agents would provide the maximum bond strength for Locator overdenture posts. Aim The aim of this study was to evaluate the bond retentive strengths of Locator overdenture posts cemented with 7 luting agents. Materials and methods One hundred and five single rooted human teeth were decoronated and randomly assigned to 7 groups (n = 15). Post spaces were prepared with Locator post drills to the depth of 6 mm. The Locator posts were cemented with Variolink II, RelyX ARC, Multilink N, RelyX Unicem, ParaCore, or MultiCore Flow resin luting agents. Zinc phosphate cement was served as control group. Specimens were stored in water at 37°C for 24 hours. Each specimen was loaded in tension in an Instron universal testing machine. The maximum force required to dislodge each Locator post was recorded. Means and standard deviations were calculated and data were statistically analyzed with one-way analysis of variance (ANOVA). Results The highest mean bond strength value for Locator posts was recorded for MultiCore® Flow group (mean = 550.1 N), while the lowest mean value was for RelyX Unicem™ resin cement group (mean = 216.8 N). A statistically significant difference in mean locator overdenture post bond strength was observed between the 7 cement types (p < 0.0001). ParaCore™ and MultiCore® Flow groups had significantly higher bond strength than all other groups, but they were not differed from each other. Conclusion Bond strength of Locator overdenture posts were influenced by the type of luting agents. MultiCore Flow and ParaCore resin cements offered the greatest retention. Clinical significance The type of luting agents had a significant effect on the retention of Locator posts. The use of Core buildup resin cements as luting agent with Locator post demonstrated the greatest retention. How to cite this article Aleisa K. Bond Strength of Overdenture Locator Posts Cemented with Seven Luting Agents. J Contemp Dent Pract 2013;14(4):675-680.


2019 ◽  
Vol 44 (4) ◽  
pp. 379-385 ◽  
Author(s):  
EJ Go ◽  
Y Shin ◽  
JW Park

SUMMARY Objectives: The purpose of this study was to measure the microshear bond strength (μSBS) of four different self-adhesive resin cements with/without 10-methacryloyloxydecyl dihydrogen phosphate (MDP)-containing primer to zirconium ceramics and to evaluate the effect of zirconia primers on these self-adhesive resin cements (SARCs). Methods and Materials: Zirconia blocks (20 × 20 × 8 mm3) were prepared and divided into eight groups (n=20). They were sandblasted (50 μm Al2O3) and treated as follows: no primer or primer (Z-Primer Plus). Four self-adhesive resin cements (MDP-containing: Permacem 2.0 [PC], Clearfil SA luting [CS]; non–MDP-containing: Rely-X U200 [RU], Maxcem Elite [ME]) were bonded to the zirconia surface. After thermocycling, a μSBS test was performed. The failure mode was analyzed using light microscopy. Statistical analysis of μSBS was performed using one-way analysis of variance and two-sample t-test with post hoc Tukey test. The loss rate was evaluated using the Fisher's exact test and χ2 test with post hoc Tukey test (p&lt;0.05). Results: Within the no primer groups, the PC and CS groups showed higher bond strength than the RU and ME groups. Comparing the μSBS of the no primer and primer groups in the same SARCs, the RU/P group was higher than the RU group, and the ME/P group was higher than the ME group. No significant difference was observed between the PC and PC/P groups and between the CS and CS/P groups. Conclusions: Non–MDP-containing SARC showed the increased bonding value with MDP-containing primer to zirconia ceramics. The bond strength of MDP-containing SARCs was not affected significantly by the use of zirconia primer.


2015 ◽  
Vol 40 (5) ◽  
pp. 524-532 ◽  
Author(s):  
DP Lise ◽  
J Perdigão ◽  
A Van Ende ◽  
O Zidan ◽  
GC Lopes

SUMMARY Objectives To investigate the effect of hydrofluoric acid (HF) etching, silane solution, and adhesive system application on the microshear bond strength (μSBS) of lithium disilicate glass-ceramic (LD) to three resin cements. Materials and Methods Circular bonding areas were delimited on the lithium disilicate surfaces using a perforated adhesive tape. Specimens were assigned to 18 subgroups (n=12) according to surface treatment: NT = no treatment; HF = 4.8% HF for 20 seconds; silane solution: (1) no silane; (2) Monobond Plus, a silane/10-methacryloyloxydecyl dihydrogen phosphate solution for 60 seconds; (3) Monobond Plus+ExciTE F DSC, a dual-cure adhesive; and resin cement: (1) Variolink II, a bisphenol A diglycidyl ether dimethacrylate (bis-GMA)–based, hand-mixed, dual-cure resin cement; (2) Multilink Automix, a bis-GMA–based, auto-mixed, dual-cure resin cement; (3) RelyX Unicem 2, a self-adhesive, auto-mixed, dual-cure resin cement. Tygon tubes (Ø=0.8 mm) were used as cylinder matrices for resin cement application. After 24 hours of water storage, the specimens were submitted to the μSBS test. Mode of failure was evaluated under an optical microscope and classified as adhesive, mixed, cohesive in resin cement, or cohesive in ceramic. Data were statistically analyzed with three-way analysis of variance and Dunnett test (p&lt;0.05). Results When means were pooled for the factor surface treatment, HF resulted in a significantly higher μSBS than did NT (p&lt;0.0001). Regarding the use of a silane solution, the mean μSBS values obtained with Monobond Plus and Monobond Plus+ExciTE F DSC were not significantly different but were higher than those obtained with no silane (p&lt;0.001). Considering the factor resin cement, Variolink II resulted in a significantly higher mean μSBS than did RelyX Unicem 2 (p&lt;0.03). The mean μSBS for Multilink Automix was not significantly different from those of Variolink II and RelyX Unicem 2. According to Dunnett post hoc test (p&lt;0.05), there was no significant difference in μSBS between the different resin cements for HF-etched and silanized (with or without adhesive application) LD surfaces. Conclusion LD may benefit from pretreatment of the inner surface with HF and silanization, regardless of the resin cement used.


2019 ◽  
Vol 22 (2) ◽  
pp. 275-280
Author(s):  
Beatriz Curvello de Mendonça ◽  
William Matthew Negreiros ◽  
Marcelo Giannini

Objective: to evaluate the effect of aluminum oxide sandblasting (AOS), argon plasma application (APL) and their combination (AOS+APL) on the shear bond strength (SBS) of dual-cure resin cement (Panavia F 2.0, Kuraray Noritake) to two zirconiabased ceramics (Lava, 3M ESPE and Katana, Kuraray Noritake). Material and Methods: One hundred twenty zirconia plates (13 mm in length X 5 mm in width X 1 mm in thickness) were prepared and treated according to the following treatments: 1- AOS, 2- APL,3- AOS+APL and 4- no treatment (control). After treatments, resin cement cylinders (1.4 mm in diameter x 1 mm in height) bonded to zirconia surface were obtained by filling up the silicon matrix. The shear bond test was performed following storage of the samples for 24 hours and one year. Bond strength values were recorded in MPa and the data were analyzed by three-way ANOVA and Tukey post-hoc test (preset alpha of 0.05). Results: In general, AOS and AOS+APL showed the higher SBS. After one-year storage, SBS of the resin cement to the Katana zirconia did not reduce, regardless of the zirconia surface treatment. Conclusion: AOS alone was able to increase the SBS of the resin cement to both zirconia ceramics compared to control and SBS remained stable after one year depending on type of zirconia ceramic.KeywordsAluminum Oxide; Ceramics; Plasma; Resin Cements


2015 ◽  
Vol 40 (5) ◽  
pp. E206-E221 ◽  
Author(s):  
RD Pereira ◽  
ADCM Valdívia ◽  
AA Bicalho ◽  
SD Franco ◽  
D Tantbirojn ◽  
...  

SUMMARY Objectives This study tested the hypothesis that photoactivation timing and resin cement affect mechanical properties and bond strength of fiberglass posts to root dentin at different depths. Methods Fiberglass posts (Exacto, Angelus) were luted with RelyX Unicem (3M ESPE), Panavia F 2.0 (Kuraray), or RelyX ARC (3M ESPE) using three photoactivation timings: light curing immediately, after three minutes, or after five minutes. Push-out bonding strength, PBS (n=10) was measured on each root region (coronal, middle, apical). The elastic modulus (E) and Vickers hardness (VHN) of the cement layer along the root canal were determined using dynamic indentation (n=5). A strain-gauge test was used to measure post-gel shrinkage of each cement (n=10). Residual shrinkage stress was assessed with finite element analysis. Data were analyzed with two-way analysis of variance in a split-plot arrangement and a Tukey test (α=0.05). Multiple linear regression analysis was used to determine the influence of study factors. Results The five-minute delay photoactivation timing significantly increased the PBS for all resin cements evaluated. The PBS decreased significantly from coronal to apical root canal regions. The mean values for E and VHN increased significantly with the delayed photoactivation for RelyX Unicem and decreased from coronal to apical root regions for all resin cements with the immediate-curing timing. Conclusions The PBS of fiber posts to root dentin, E, and VHN values were affected by the root canal region, photoactivation timing, and resin cement type. Shrinkage stress values decreased gradually with delayed photoactivation for all the cements.


2016 ◽  
Vol 2016 ◽  
pp. 1-7 ◽  
Author(s):  
Jong-Eun Kim ◽  
Jee-Hwan Kim ◽  
June-Sung Shim ◽  
Byoung-Duck Roh ◽  
Yooseok Shin

Purpose.Although several studies evaluating the mechanical properties of Ce-TZP/Al2O3have been published, to date, no study has been published investigating the bonding protocol between Ce-TZP/Al2O3and resin cement. The aim of this study was to evaluate the shear bond strength to air-abraded Ce-TZP/Al2O3when primers and two different cement types were used.Materials and Methods.Two types of zirconia (Y-TZP and Ce-TZP/Al2O3) specimens were further divided into four subgroups according to primer application and the cement used. Shear bond strength was measured after water storage for 3 days or 5,000 times thermocycling for artificial aging.Results.The Y-TZP block showed significantly higher shear bond strength than the Ce-TZP/Al2O3block generally. Primer application promoted high bond strength and less effect on bond strength reduction after thermocycling, regardless of the type of cement, zirconia block, or aging time.Conclusions.Depending on the type of the primer or resin cement used after air-abrasion, different wettability of the zirconia surface can be observed. Application of primer affected the values of shear bond strength after the thermocycling procedure. In the case of using the same bonding protocol, Y-TZP could obtain significantly higher bond strength compared with Ce-TZP/Al2O3.


2012 ◽  
Vol 37 (4) ◽  
pp. 397-405 ◽  
Author(s):  
K Bitter ◽  
J Perdigão ◽  
M Exner ◽  
K Neumann ◽  
AM Kielbassa ◽  
...  

SUMMARY The aim of this study was to investigate the effect of thermomechanical loading (TML) on the bond strength of fiber posts luted with three different resin cements. Sixty-six extracted human anterior teeth were endodontically treated and restored with fiber posts (RelyX Fiber Posts, 3M ESPE) using three commercially available resin cements and three corresponding core build-up materials (n=22 each): Panavia F 2.0/Clearfil DC Core Automix (Kuraray), Variolink II/Multicore Flow (Ivoclar Vivadent), and RelyX Unicem/Filtek Z250 (3M ESPE). Twelve specimens of each group received all-ceramic crowns and were subjected to TML. The other 10 specimens were stored in saline solution for 24 hours. The roots were sectioned and bond strength was measured using a push-out test. Adhesive interfaces of two specimens of each group subjected to TML were analyzed using field emission scanning electron microscopy (FESEM). Bond strengths of fiber posts were significantly affected by the type of resin cement (p&lt;0.0005) and TML (p&lt;0.0005; two-way analysis of variance). TML significantly reduced bond strengths for all materials ((6.0 (6.2) MPa)) compared with initial bond strengths ((14.9 (10.4) MPa)). RelyX Unicem resulted in significantly higher bond strengths before ((18.3 (10.3) MPa)) and after TML ((9.8 (7.5) MPa)) compared with the other materials (p&lt;0.0005; Tukey HSD). Using FESEM, Variolink II and Panavia F demonstrated a hybrid layer partly detached from the underlying resin cement, whereas no hybrid layer was observed for RelyX Unicem. The decrease in bond strength after TML suggests that retention of fiber posts may be reduced after clinical function. Therefore, endodontically treated teeth that are restored using fiber posts may benefit from additional reinforcement via coronal restorations using adequate ferrules and/or adhesive techniques.


2018 ◽  
Vol 17 ◽  
pp. 1-7
Author(s):  
Estéfani Maminis Soares Couto ◽  
Bruna de Oliveira Reis ◽  
Thaís Yumi Umeda Suzuki ◽  
Wirley Gonçalves Assunção ◽  
André Luiz Fraga Briso ◽  
...  

Aim: The aim of this study was to verify the microshear bond strength of conventional and self-adhesive resin cements to feldsphatic ceramic. Methods: Twenty discs of Starlight ceramic (Degudent) were made (15mm x 2mm). The bonding procedure was accomplished by insertion of resin cements into tubes of 0.7mm internal diameter in contact with the ceramic. The resin cements used were: RelyX ARC (3M Espe), Panavia F (Kuraray), RelyX Unicem (3M Espe) and seT (SDI). Total of six tubes of each material on each ceramic disc. The specimens were tested for microshear in a universal testing machine, 24hours and 6months after bonding procedure. Values of microshear bonding strength (MPa) were subjected to ANOVA and Fisher PLSD test (p<0.05). Results: For 24hours analysis, RelyX ARC showed the highest microshear bonding strength without statistical difference to RelyX Unicem and seT. Panavia F showed the lowest values of microshear bonding strength in both periods. In the analysis after 6months there was a significant increase in the microshear bonding strength values for all cements compared to 24hours. Only for RelyX ARC, the increase was not statistically significant. Conclusion: In conclusion, the bond strength depends mainly on the type of resin cement used, and the self-adhesive cements behave similarly to conventional resin cement.


2016 ◽  
Vol 95 (13) ◽  
pp. 1487-1493 ◽  
Author(s):  
N. Hirose ◽  
R. Kitagawa ◽  
H. Kitagawa ◽  
H. Maezono ◽  
A. Mine ◽  
...  

An experimental cavity disinfectant (ACC) that is intended to be used for various direct and indirect restorations was prepared by adding an antibacterial monomer 12-methacryloyloxydodecylpyridinum bromide (MDPB) at 5% into 80% ethanol. The antibacterial effectiveness of ACC and its influences on the bonding abilities of resin cements were investigated. To examine the antibacterial activity of unpolymerized MDPB, the minimum inhibitory and bactericidal concentrations (MIC and MBC) were determined for Streptococcus mutans, Lactobacillus casei, Actinomyces naeslundii, Parvimonas micra, Enterococcus faecalis, Fusobacterium nucleatum, and Porphyromonas gingivalis. Antibacterial activities of ACC and the commercial cavity disinfectant containing 2% chlorhexidine and ethanol (CPS) were evaluated by agar disk diffusion tests through 7 bacterial species and by MIC and MBC measurement for S. mutans. The effects of ACC and CPS to kill bacteria in dentinal tubules were compared with an S. mutans–infected dentin model. Shear bond strength tests were used to examine the influences of ACC on the dentin-bonding abilities of a self-adhesive resin cement and a dual-cure resin cement used with a primer. Unpolymerized MDPB showed strong antibacterial activity against 7 oral bacteria. ACC produced inhibition zones against all bacterial species similar to CPS. For ACC and CPS, the MIC value for S. mutans was identical, and the MBC was similar with only a 1-step dilution difference (1:2). Treatment of infected dentin with ACC resulted in significantly greater bactericidal effects than CPS ( P < 0.05, analysis of variance and Tukey’s honest significant difference test). ACC showed no negative influences on the bonding abilities to dentin for both resin cements, while CPS reduced the bond strength of the self-adhesive resin cement ( P < 0.05). This study clarified that the experimental cavity disinfectant containing 5% MDPB is more effective in vitro than the commercially available chlorhexidine solution to eradicate bacteria in dentin, without causing any adverse influences on the bonding abilities of resinous luting cements.