scholarly journals Forensic medical determination of harm caused to human health in environmental crime cases

2021 ◽  
Vol 7 (3) ◽  
pp. 186-192
Author(s):  
Semyon V. Kuznetsov ◽  
Yuri A. Molin ◽  
Sergey Yu. Melikhov

The article describes one of the most urgent needs of the investigation the development of a fundamentally new approach to the forensic medical assessment of harm to human health caused by environmental crimes. Th e special signifi cance of new approaches to establishing a causal relationship between a committed environmental off ense and harm to life and (or) health, including for distinguishing from other possible anthropogenic impacts, is shown. A practical example of expert assistance to the investigation in establishing the circumstances to be proved during the investigation of an environmental crime is given.

2017 ◽  
Vol 30 (1) ◽  
pp. 273-289
Author(s):  
Anmari Meerkotter

The Constitutional Court (CC) judgment of Lee v Minister of Correction Services 2013 2SA 144 (CC) is a recent contribution to transformative constitutional jurisprudence in the field of the law of delict. This matter turned on the issue of factual causation in the context of wrongful and negligent systemic omissions by the state. In this case note, I explore the law relating to this element of delictual liability with specific regard to the traditional test for factual causation – the conditio sine qua non (‘but-for’) test. In particular, I note the problems occasioned by formalistic adherence to this test in the context of systemic state omissions as evidenced by the SCA judgment in the same matter. I also consider the manner in which English courts have addressed this problem. Thereafter, I analyse the CC’s broader approach to the determination of factual causation as one based on common sense and justice. I argue that this approach endorses a break from a formalistic application of the test and constitutes a step towards an approach which resonates with the foundational constitutional values of freedom, dignity and equality. Furthermore, it presents an appropriate solution to the problems associated with factual causation where systemic omissions are concerned. I then consider the transformative impact of the Lee judgment. In particular, I argue that the broader enquiry favoured by the CC facilitates the realisation of constitutionally guaranteed state accountability, and amounts to an extension of the existing norm of accountability jurisprudence. Hence, I contend that the judgment presents a further effort by the Constitutional Court to effect wholesale the constitutionalisation of the law of delict, as well as a vindicatory tool to be used by litigants who have been adversely affected by systemic state omissions.


Author(s):  
Romain Desplats ◽  
Timothee Dargnies ◽  
Jean-Christophe Courrege ◽  
Philippe Perdu ◽  
Jean-Louis Noullet

Abstract Focused Ion Beam (FIB) tools are widely used for Integrated Circuit (IC) debug and repair. With the increasing density of recent semiconductor devices, FIB operations are increasingly challenged, requiring access through 4 or more metal layers to reach a metal line of interest. In some cases, accessibility from the front side, through these metal layers, is so limited that backside FIB operations appear to be the most appropriate approach. The questions to be resolved before starting frontside or backside FIB operations on a device are: 1. Is it do-able, are the metal lines accessible? 2. What is the optimal positioning (e.g. accessing a metal 2 line is much faster and easier than digging down to a metal 6 line)? (for the backside) 3. What risk, time and cost are involved in FIB operations? In this paper, we will present a new approach, which allows the FIB user or designer to calculate the optimal FIB operation for debug and IC repair. It automatically selects the fastest and easiest milling and deposition FIB operations.


2018 ◽  
pp. 138-146 ◽  
Author(s):  
Karin Abraham ◽  
Eckhard Flöter

The presence of polysaccharides in cane and beet raw juices causes several negative effects during the sugar manufacture. These are usually mitigated by enzymatic decomposition of dextrans. Such effects not only depend on the content, but also on the molecular mass distribution. This means that the different dextran fractions specifically affect the process. An accurate process control hence requires the most precise knowledge about the existing content and the molecular mass distribution present. A detailed understanding of the specific processing problems and also a targeted enzyme application hence requires the determination of a total dextran content and also its characterization including the differentiation between the different dextran fractions. An accurate analytical tool which equally satisfies industrial applicability is still lacking. To improve on this situation, two new approaches for the determination of dextran were developed and benchmarked against the commonly used and established Haze Method, which is rather inaccurate and also sensitive to molecular mass variation. The two new approaches are both based on polarimetry. These two methods indicate to be superior over the Haze Method with respect two molecular mass variation and hence enable the determination of a broader molecular size range including also low molecular mass dextrans.


2020 ◽  
Vol 16 ◽  
Author(s):  
Ramazan Akçan ◽  
Halit Canberk Aydogan ◽  
Mahmut Şerif Yıldırım ◽  
Burak Taştekin ◽  
Necdet Sağlam

Background/aim: Use of nanomaterials in the healthcare applications increases in parallel to technological developments. It is frequently utilized in diagnostic procedures, medications and in therapeutic implementations. Nanomaterials take place among key components of medical implants, which might be responsible for certain toxic effects on human health at nano-level. In this review, nanotoxicological effects, toxicity determination of nanobiomaterials used in human body and their effects on human health are discussed. Material and Method: A detailed review of related literature was performed and evaluated as per nanomaterials and medical implants. Results and Conclusion: The nanotoxic effects of the materials applied to human body and the determination of its toxicity are important. Determination of toxicity for each nanomaterial requires a detailed and multifactorial assessment considering the properties of these materials. There are limited studies in the literature regarding the toxic effects of nanomaterials used in medical implants. Although these implants are potentially biocompatible and biodegradable, it is highly important to discuss nanotoxicological characteristics of medical implant.


Author(s):  
Peter J. Stoett

This chapter looks at whether and how international organizations and criminal law can help us deal effectively with transnational environmental crimes and, more broadly, with environmental insecurity and injustice. It explores the question of whether the climate change justice agenda can benefit from the expanded pursuit of transnational environmental crime. The chapter asks whether international environmental law, refurbished, act as a mitigating factor in climate change. It concludes that while current international legal instruments can help spur additional action, by themselves, they will prove inadequate. Consequently, one idea proposed is a new international environmental court to deter all forms of ecocide.


Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 3070
Author(s):  
Sebastian Iwaszenko ◽  
Jakub Munk ◽  
Stefan Baron ◽  
Adam Smoliński

Modern dentistry commonly uses a variety of imaging methods to support diagnosis and treatment. Among them, cone beam computed tomography (CBCT) is particularly useful in presenting head structures, such as the temporomandibular joint (TMJ). The determination of the morphology of the joint is an important part of the diagnosis as well as the monitoring of the treatment results. It can be accomplished by measurement of the TMJ gap width at three selected places, taken at a specific cross-section. This study presents a new approach to these measurements. First, the CBCT images are denoised using curvilinear methods, and the volume of interest is determined. Then, the orientation of the vertical cross-section plane is computed based on segmented axial sections of the TMJ head. Finally, the cross-section plane is used to determine the standardized locations, at which the width of the gap between condyle and fossa is measured. The elaborated method was tested on selected TMJ CBCT scans with satisfactory results. The proposed solution lays the basis for the development of an autonomous method of TMJ index identification.


Sign in / Sign up

Export Citation Format

Share Document