scholarly journals RE-DESIGN SISTEM DISTRIBUSI AIR BERSIH DAN FIRE HYDRANT DI GEDUNG PLN UP3B KALSELTENG

JTAM ROTARY ◽  
2021 ◽  
Vol 3 (1) ◽  
pp. 29
Author(s):  
Anas Satria Aji ◽  
Rudi Siswanto

Sistem penyediaan dan distribusi air bersih di gedung-gedung bertingkat sering mengalami kendala. Tidak terkecuali PT. PLN (Persero) Gedung UP3B Kalselteng yang tidak luput dari permasalahan tersebut. Untuk itu perlu dilakukan perancangan ulang sistem distribusi dan penyediaan air bersih serta hidran kebakaran pada gedung. Tujuan dari penelitian ini antara lain menganalisis kebutuhan dan distribusi air bersih dan hidran kebakaran di dalam gedung. Kebutuhan air bersih dihitung berdasarkan jumlah penduduk yang mengkonsumsi air bersih, jenis dan jumlah unit beban alat perpipaan. Perhitungan head loss pada pipa menggunakan persamaan Hazen - William, Darcy-Weisbach dan Colebrook-White. Clean water supply and distribution systems in high-risk buildings often experience problems. No exception is the PT. PLN (Persero) UP3B Kalselteng Building which did not escape this problem. For this reason, it is necessary to re-design the distribution system and provide clean water and fire hydrants to the building. The objectives of this study include analyzing the needs and distribution of clean water and fire hydrants in the building. Clean water needs were calculated based on the number of people that consuming the clean water, the type and number of plumbing tools load unit. Calculation of head  loss  in  pipes  used Hazen – William, Darcy-Weisbach  and  Colebrook-White equation.Clean water supply and distribution systems in high rise buildings often experience problems. No exception is the PT. PLN (Persero) UP3B Kalselteng Building which did not escape this problem. For this reason, it is necessary to re-design the distribution system and provide clean water and fire hydrants to the building. The objectives of this study include analyzing the needs and distribution of clean water and fire hydrants in the building.Clean water needs was calculated based on the number of people that consuming the clean water, the type and number of plumbing tools load unit. Calculation of head  loss  in  pipes  used Hazen – William, Darcy-Weisbach  and  Colebrook-White equation.

2017 ◽  
Vol 19 (6) ◽  
pp. 823-837 ◽  
Author(s):  
George Tsakiris ◽  
Mike Spiliotis

Abstract Conventionally, the design of urban water supply and distribution systems is based on the assumption that all the involved parameters are known a priori and remain unaltered throughout the life cycle of the system. However, significant uncertainties do appear during the analysis and design of these systems, such as the equivalent pipe roughness and the actual internal diameters of the pipes. To study these uncertainties, the water supply and the looped water distribution systems are studied separately. For the water supply system, these uncertainties are incorporated in the analysis of the system, using the extension principle of the fuzzy sets and a new operation of the fuzzy subtraction. Based on the calculation of head losses for each branch of the system, the nodal heads are obtained as fuzzy numbers. In regard to the looped water distribution system, a methodology is developed and proposed, based on the extension principle and leading to several optimisation problems with respect to the branches of the system. The aim of the proposed methodology is to determine the α-cuts and finally produce the shape of the membership function of flows in the branches of the system. Both methodologies are illustrated by numerical examples.


2020 ◽  
Vol 21 (2) ◽  
pp. 227-235
Author(s):  
Muhammad Rizki Apritama ◽  
I Wayan Koko Suryawan ◽  
Yosef Adicita

ABSTRACTThe clean water supply system network on Lengkang Kecil Island was developed in 2019. A small portion of the community's freshwater comes from harvesting rainwater and dug wells, which are only obtained during the rainy season. The primary source of clean water used by the community comes from underwater pipelines with a daily discharge of 0.86 l/sec. The water supply of the Lengkang Kecil Island community is 74.3 m3/day, with 146 House Connections (HCs) and to serve public facilities such as elementary schools, primary health centers, and mosques. Hydraulic evaluation of clean water distribution using EPANET 2.0 software on flow velocity shows the lowest rate of 0.29 m/s and the highest of 1.21 m/s. The lowest pressure value in the distribution system is 6.94-6.96 m and headloss units in the range 0.08-0.25 m/km. These three criteria are still within the distribution network design criteria (feasible). A carbon footprint can be calculated from each activity from the analysis of the evaluation of clean water distribution networks. The most massive emissions came from pumping activities with 131 kg CO2-eq, followed by emissions from wastewater 62.5 kgCO2-eq. Further research is needed to determine the quality of wastewater and the design for a centralized wastewater treatment plant (IPALT) to improve Lengkang Kecil Island residents' living standards.Keywords: Lengkang Kecil Island, water, EPANET, carbon footprintABSTRAKJaringan sistem penyediaan air bersih pada Pulau Lengkang Kecil dimulai pada tahun 2019. Sebagian kecil air bersih yang digunakan masyarakat berasal dari pemanenan air hujan dan sumur gali yang hanya didapat pada musim hujan. Sumber air bersih utama yang digunakan masyarakat berasal dari pengaliran perpipaan bawah laut dengan debit harian 0,86 l/detik. Kebutuhan air masyarakat Pulau Lengkang Kecil adalah 74,3 m3/hari dengan 146 Sambungan Rumah (SR) serta untuk melayani fasilitas umum seperti sekolah dasar (SD), puskesmas, dan masjid. Evaluasi hidrolis distribusi air bersih dengan menggunakan software EPANET 2.0 terhadap kriteria kecepatan aliran menunjukkan nilai terendah 0,29 m/s dan tertinggi 1,21 m/s. Nilai sisa tekan dalam sistem distribusi adalah 6,94–6,96 m dan unit headloss pada kisaran 0,08–0,25 m/km. Ketiga kriteria ini masih berada dalam kriteria desain jaringan distribusi (layak). Dari analisis evaluasi jaringan distribusi air bersih, dapat dihitung jejak karbon yang dihasilkan dari setiap kegiatannya. Emisi terbesar berasal dari kegiatan pemompaan dengan nilai 131 kgCO2-eq, diikuti dengan emisi yang berasal dari air limbah dengan nilai 62,5 kgCO2-eq. Penelitian lanjutan diperlukan untuk mengetahui kualitas dari air limbah dan desain untuk instalasi pengolahan air limbah terpusat (IPALT) untuk meningkatkan taraf hidup penduduk Pulau Lengkang Kecil.Kata kunci: Pulau Lengkang Kecil, air, EPANET, jejak karbon


2011 ◽  
Vol 6 (4) ◽  
Author(s):  
Virgilio C. Rivera

Prior to Manila Water's entry into the East Zone as MWSS's concessionaire in 1997, the water supply and distribution system was characterized by low service coverage, high levels of leakage due to pilferage and deteriorating pipes, limited water availability and poor operating efficiencies. This presentation details how the MWSS PPP framework, coupled with Manila Water's multi-pronged, corporate approach, has been key to reversing the sorry state which Metro Manila's East Zone found itself in before 1997. Crucial to the success of Manila Water was the adoption of a multi-pronged corporate strategy composed of five interrelated variables: (1) Profit Model, (2) Market/Customer, (3) Resources, (4) Systems and Processes and (5) Talent and Organization. The presentation explains how these factors have come together to bring out the “virtuous cycle” in the East Zone. The numerous achievements of Manila Water over the past thirteen years, which are highlighted in the last section of the presentation, have been directly attributed to the successful corporate strategy employed by Manila Water.


2005 ◽  
Vol 15 (1) ◽  
pp. 93-109 ◽  
Author(s):  
Charles R. Ortloff

The water supply and distribution system of the Nabataean city of Petra in southwestern Jordan has been explored and mapped. Analysis of the system indicates exploitation of all possible water resources using management techniques that balance reservoir storage capacity with continuous flow pipeline systems to maintain a constant water supply throughout the year. Nabataean Petra was founded c. 300 bc; urban development progressed with later Roman administration of the city starting at ad 106; Byzantine occupation continued to the seventh century ad. Trade networks that extended throughout much of the ancient Near East and Mediterranean world intersected at Petra, and brought not only strategic and economic prominence, but also impetus to develop water resources fully to sustain demands of increasing population and city elaboration. City development was influenced by artistic, cultural and technological borrowings from Seleucid, Syro-Phoenician, Greek and Roman civilizations; the Petra water-distribution system included hydraulic technologies derived from these contacts as well as original technical innovations that helped to maintain the high living standard of city dwellers throughout the centuries. Analysis of the Nabataean water network indicates design criteria that promote stable flows and use sequential particle-settling basins to purify potable water supplies. They also promote open channel flows within piping at critical (maximum) flow rates that avoid leakage associated with pressurized systems and have the design function to match the spring supply rate to the maximum carrying capacity of a pipeline. This demonstration of engineering capability indicates a high degree of cognitive skill in solving complex hydraulic problems to ensure a stable water supply and may be posited as a key reason behind the many centuries of flourishing city life.


Author(s):  
Chalchisa Milkecha ◽  
Habtamu Itefa

This study was conducted generally by aiming assessment of the hydraulic performance of water distribution systems of Addis Ababa Science and Technology University (AASTU). In line with the main objective, this study addressed, (1) pinpointing problems of existing water supply versus demand deficit (2) evaluating the hydraulic performance of water distribution system using water GEMS and (3) recommended alternative methods for improving water demand scenarios. The University’s water supply distribution network layout was a looped system and the flow of water derived by both gravity and pressurized system. The gravity flow served for the academic and administrative staffs whereas the pressurized system of the network fed the students dormitories, cafeteria’s etc. The study revealed the existence of unmet minimum pressure requirement around the student dormitories which accounts 25.64% below the country’s building code standard during the peak hour consumption. The result of the water demand projection showed an increment of 2.5 liter per capita demand (LPCD) in every five years. Hence, first, the university’s water demand was projected and then hydraulic parameters such as; pressure, head loss and velocity were modeled for both the existing and the improved water supply distribution. The finding of the study was recommended to the university’s water supply project and institutional development offices for its future modification and rehabilitation works.


2015 ◽  
Vol 20 (24) ◽  
Author(s):  
B Guzman-Herrador ◽  
A Carlander ◽  
S Ethelberg ◽  
B Freiesleben de Blasio ◽  
M Kuusi ◽  
...  

A total of 175 waterborne outbreaks affecting 85,995 individuals were notified to the national outbreak surveillance systems in Denmark, Finland and Norway from 1998 to 2012, and in Sweden from 1998 to 2011. Between 4 and 18 outbreaks were reported each year during this period. Outbreaks occurred throughout the countries in all seasons, but were most common (n = 75/169, 44%) between June and August. Viruses belonging to the Caliciviridae family and Campylobacter were the pathogens most frequently involved, comprising n = 51 (41%) and n = 36 (29%) of all 123 outbreaks with known aetiology respectively. Although only a few outbreaks were caused by parasites (Giardia and/or Cryptosporidium), they accounted for the largest outbreaks reported during the study period, affecting up to 53,000 persons. Most outbreaks, 124 (76%) of those with a known water source (n = 163) were linked to groundwater. A large proportion of the outbreaks (n = 130/170, 76%) affected a small number of people (less than 100 per outbreak) and were linked to single-household water supplies. However, in 11 (6%) of the outbreaks, more than 1,000 people became ill. Although outbreaks of this size are rare, they highlight the need for increased awareness, particularly of parasites, correct water treatment regimens, and vigilant management and maintenance of the water supply and distribution systems.


Author(s):  
Wenjin Xue ◽  
Christopher W. K. Chow ◽  
John van Leeuwen

Abstract The bacterial regrowth potential (BRP) method was utilised to indirectly measure the assimilable organic carbon (AOC) as an indicator for the assessment of the microbial regrowth potential in drinking water distribution systems. A model using various microbial growth parameters was developed in order to standardise the experimental interpretation for BRP measurement. This study used 82 experimental BRP data sets of water samples collected from the water treatment plant to locations (customer taps) in the distribution system. The data were used to model the BRP process (growth curve) by a data fitting procedure and to obtain a best-fitted equation. Statistical assessments and model validation for evaluating the equation obtained by fitting these 82 sets of data were conducted, and the results show average R2 values were 0.987 for treated water samples (collected at the plant prior to chlorination) and 0.983 for tap water (collected at the customer taps). The F values obtained from the F-test are all exceeded their corresponding F critical values, and the results from the t-test also showed a good outcome. These results indicate this model would be successfully applied in modelling BRP in drinking water supply systems.


2019 ◽  
Vol 5 (5) ◽  
pp. 1197-1204 ◽  
Author(s):  
Gulfam Shahzad ◽  
Rashid Rehan ◽  
Muhammad Fahim

The assessment of existing water supply services was carried out through selected performance indicators with the aim of using that data in future for strategic planning of urban Mardan. The key performance indictors studied were selected to assess both the quantity and quality of water. The quality of water was assessed by turbidity, pH, and E-coli tests for samples collected at the start, middle, and tail end of the distribution system. The quantity of water supplied was measured by calculating discharges from water tapes at the three selected locations in the distribution system. A total of thirty samples were collected from ten union councils out of fourteen covering urban Mardan. A number of issues are highlighted in the overall water supply infrastructure and short, mid, and long term remedial measures are recommended. The results are presented in the form of an interactive map using Google Earth and VBA based dynamic database. It was found that the overall quality of water is generally acceptable for drinking. However, the presence of bacteria is an issue in many cases which needs to be resolved. A significant decrease in discharge is observed in the distribution systems away from the source due to leakages and illegal connections. A comprehensive overhaul of both management and infrastructure is required for sustainable and satisfactory level of services.


Resources ◽  
2019 ◽  
Vol 8 (4) ◽  
pp. 162 ◽  
Author(s):  
Barbara Tchórzewska-Cieślak ◽  
Katarzyna Pietrucha-Urbanik ◽  
Dorota Papciak

Given that a consequence of a lack of stability of the water in a distribution system is increased susceptibility to secondary contamination and, hence, a threat to consumer health, in the work detailed here we assessed the risk of such a system experiencing quality changes relating to the biological and chemical stability of water intended for drinking. Utilizing real operational data from a water treatment station, the presented analysis of the stability was performed based on the fault tree method. If they are to protect their critical-status water supply infrastructure, water supply companies should redouble their efforts to distribute stable water free of potentially corrosive properties. To that end, suggestions are made on the safeguarding of water distribution systems, with a view to ensuring the safety of operation and the long-term durability of pipes.