scholarly journals Application of intraoperative B-mode ultrasound and shear wave elastography for glioma grading

2021 ◽  
Vol 11 (6) ◽  
pp. 2733-2743
Author(s):  
Lu Yin ◽  
Linggang Cheng ◽  
Fumin Wang ◽  
Xueli Zhu ◽  
Yue Hua ◽  
...  
Author(s):  
Anders Batman Mjelle ◽  
Anesa Mulabecirovic ◽  
Roald Flesland Havre ◽  
Edda Jonina Olafsdottir ◽  
Odd Helge Gilja ◽  
...  

Abstract Purpose Liver elastography is increasingly being applied in screening for and follow-up of pediatric liver disease, and has been shown to correlate well with fibrosis staging through liver biopsy. Because time is of the essence when examining children, we wanted to evaluate if a reliable result can be achieved with fewer acquisitions. Materials and Methods 243 healthy children aged 4–17 years were examined after three hours of fasting. Participants were divided into four age groups: 4–7 years; 8–11 years; 12–14 years and 15–17 years. Both two-dimensional shear wave elastography (2D-SWE; GE Logiq E9) and point shear wave elastography (pSWE; Samsung RS80A with Prestige) were performed in all participants, while transient elastography (TE, Fibroscan) was performed in a subset of 87 children aged 8–17 years. Median liver stiffness measurement (LSM) values of 3, 4, 5, 6, 7, and 8 acquisitions were compared with the median value of 10 acquisitions (reference standard). Comparison was performed for all participants together as well as within every specific age group. We investigated both the intraclass correlation coefficient (ICC) with absolute agreement and all outliers more than 10 %, 20 % or ≥ 0.5 or 1.0 kPa from the median of 10 acquisitions. Results For all three systems there was no significant difference between three and ten acquisitions, with ICCs ≥ 0.97. All systems needed 4 acquisitions to achieve no LSM deviating ≥ 1.0 kPa of a median of ten. To achieve no LSM deviating ≥ 20 % of a median of ten acquisitions, pSWE and TE needed 4 acquisitions, while 2D-SWE required 6 acquisitions. Conclusion Our results contradict recommendations of 10 acquisitions for pSWE and TE and only 3 for 2D-SWE.


2019 ◽  
Author(s):  
Mihaela Vlad ◽  
Ioana Golu ◽  
Maria Oprea ◽  
Daniela Amzar ◽  
Melania Balas ◽  
...  

2016 ◽  
Vol 25 (4) ◽  
pp. 525-532 ◽  
Author(s):  
Monica Lupșor-Platon ◽  
Radu Badea ◽  
Mirela Gersak ◽  
Anca Maniu ◽  
Ioana Rusu ◽  
...  

There has been great interest in the development of non-invasive techniques for the diagnosis of liver fibrosis in chronic liver diseases, including ultrasound elastographic methods. Some of these methods have already been adequately studied for the non-invasive assessment of diffuse liver diseases. Others, however, such as two-dimensional Shear Wave Elastography (SWE), of more recent appearance, have yet to be validated and some aspects are for the moment incompletely elucidated. This review discusses some of the aspects related to two-dimensional SWE: the examination technique, the examination performance indicators, intra and interobserver agreement and clinical applications. Recommendations for a high-quality examination technique are formulated. Key words:  –  –  – Two-dimensional Shear Wave Elastography. Abbreviations: 2D- SWE: Two-dimensional Shear Wave Elastography; 3D- SWE: Three-dimensional Shear Wave Elastography; AUROC: area under the receiver operating characteristic curves; ARFI Acoustic Radiation Force Impulse Elastography; EFSUMB: European Federation of Societies for Ultrasound in Medicine and Biology; HVPG: hepatic venous pressure gradient; LS: liver stiffness; LR: likelihood ratio; NPV: negative predictive value; PPV: positive predictive value; ROI: region of interest; RT-E: Real Time-Elastography; Se: sensitivity; Sp: specificity; TE: Transient Elastography; US: ultrasound; VM: valid measurement; E: Young’s modulus


2018 ◽  
Vol 68 (12) ◽  
pp. 2818-2822
Author(s):  
Maria Cristina Oprea ◽  
Mihaela Vlad ◽  
Ioana Golu ◽  
Ioan Sporea ◽  
Lazar Fulger

Thyroid nodules are a common pathology found in 50 to 60% of otherwise healthy people. Diagnostic imaging techniques are help discriminating between benign and malignant nodules, while fine needle aspiration is still a gold standard. Shear wave elastography, a recent imaging technique, holds the promise to become reliable diagnostic tools and is currently used in combination with ultrasound. We here report data obtained in a series of 52 thyroid nodules analysed by means of elastography, as well as conventional and Doppler ultrasound. We found no differences in age, nodule and thyroid volume, length, width, thickness and maximum diameter between benign and malignant lesions. Several sonographic patterns are considered to be predictive of malignancy, out of which we only found the intranodular blood flow to be statistically significant. By the means of shear wave elastography we have first assessed tissue elasticities, which are shown in a range of colours, depending on tissue elasticity/stiffness. Then, we have measured and recorded four parameters automatically displayed by the system, namely SWE-mean, SWE-max, SWE-SD and SWE-ratio. Data analysis showed all these quantitative parameters had good sensitivity, specificity, positive predictive value, negative predictive value and area under the curve, as calculated by the ROC curve. As with these parameters, the cut-off points were lower than in literature, still able to indicate reliable diagnoses, which were confirmed by histopathological exam. Our conclusion is that shear wave elastography has great potential for reliably and accurately diagnosing thyroid malignancies.


Sign in / Sign up

Export Citation Format

Share Document