Extreme-flood-related peat blocks: An Anthropocene analogue to ancient coal-forming environments

2021 ◽  
Vol 91 (3) ◽  
pp. 243-261
Author(s):  
JUAN PEDRO RODRÍGUEZ-LÓPEZ ◽  
ANA R. SORIA ◽  
CARLOS L. LIESA

Abstract Coal clasts associated with extreme floods are prone to survive and maintain their large size, contrary to the general belief that distance from the parent peat layer reduces the size of transported clasts. Contrary to apparent logic, moreover, a second flood event favors the preservation potential of such soft organic clasts, this being the minimal fragmentation. An Anthropocene example from an urban park in Spain demonstrates that peat clasts up to 1 m long can survive due to flotation for a distance of almost a hundred meters and are well preserved and stabilized thanks to a second flood. These peat blocks were generated by catastrophic flooding of urban peatlands along the Ebro River (city of Zaragoza) during exceptional rainfalls in Iberia. The water flow from the Ebro River flooded the peatland at the surface of the meander, ripping up peat clasts from a shear or detachment level formed by an indurated level characterized by rounded quartzite pebbles, which acted as a hydrological discontinuity surface. Extensive evidence of the paleoflow direction is provided by oriented crushed reeds and the widespread occurrence of imbricated and thrusted peat blocks on the eroded and exposed peatland and in the main urban accumulation areas. To be specific, peat blocks and minor clasts accumulated in four areas associated with different modes of transport and topographic steps. From proximal to distal these are as follows: i) a proximal rim including thrusted peat blocks on the eroded peatland, ii) two intermediate accumulation zones associated with topographic steps in the park, characterized by peat-clast imbrication, iii) gravity-fall peat clasts deposited in an artificial channel in the park, and iv) peat rafts of more than 1 m in diameter scattered over the surface of the park (at a distance of 90 m from the eroded peatland).

Author(s):  
R. A. Ricks ◽  
Angus J. Porter

During a recent investigation concerning the growth of γ' precipitates in nickel-base superalloys it was observed that the sign of the lattice mismatch between the coherent particles and the matrix (γ) was important in determining the ease with which matrix dislocations could be incorporated into the interface to relieve coherency strains. Thus alloys with a negative misfit (ie. the γ' lattice parameter was smaller than the matrix) could lose coherency easily and γ/γ' interfaces would exhibit regularly spaced networks of dislocations, as shown in figure 1 for the case of Nimonic 115 (misfit = -0.15%). In contrast, γ' particles in alloys with a positive misfit could grow to a large size and not show any such dislocation arrangements in the interface, thus indicating that coherency had not been lost. Figure 2 depicts a large γ' precipitate in Nimonic 80A (misfit = +0.32%) showing few interfacial dislocations.


Author(s):  
H. Weiland ◽  
D. P. Field

Recent advances in the automatic indexing of backscatter Kikuchi diffraction patterns on the scanning electron microscope (SEM) has resulted in the development of a new type of microscopy. The ability to obtain statistically relevant information on the spatial distribution of crystallite orientations is giving rise to new insight into polycrystalline microstructures and their relation to materials properties. A limitation of the technique in the SEM is that the spatial resolution of the measurement is restricted by the relatively large size of the electron beam in relation to various microstructural features. Typically the spatial resolution in the SEM is limited to about half a micron or greater. Heavily worked structures exhibit microstructural features much finer than this and require resolution on the order of nanometers for accurate characterization. Transmission electron microscope (TEM) techniques offer sufficient resolution to investigate heavily worked crystalline materials.Crystal lattice orientation determination from Kikuchi diffraction patterns in the TEM (Figure 1) requires knowledge of the relative positions of at least three non-parallel Kikuchi line pairs in relation to the crystallite and the electron beam.


Author(s):  
Patricia G. Calarco ◽  
Margaret C. Siebert

Visualization of preimplantation mammalian embryos by electron microscopy is difficult due to the large size of the ircells, their relative lack of internal structure, and their highly hydrated cytoplasm. For example, the fertilized egg of the mouse is a single cell of approximately 75μ in diameter with little organized cytoskelet on and apaucity ofor ganelles such as endoplasmic reticulum (ER) and Golgi material. Thus, techniques that work well on tissues or cell lines are often not adaptable to embryos at either the LM or EM level.Over several years we have perfected techniques for visualization of mammalian embryos by LM and TEM, SEM and for the pre-embedding localization of antigens. Post-embedding antigenlocalization in thin sections of mouse oocytes and embryos has presented a more difficult challenge and has been explored in LR White, LR Gold, soft EPON (after etching of sections), and Lowicryl K4M. To date, antigen localization has only been achieved in Lowicryl-embedded material, although even with polymerization at-40°C, the small ER vesicles characteristic of embryos are unrecognizable.


Author(s):  
K. Ohi ◽  
M. Mizuno ◽  
T. Kasai ◽  
Y. Ohkura ◽  
K. Mizuno ◽  
...  

In recent years, with electron microscopes coming into wider use, their installation environments do not necessarily give their performance full play. Their environmental conditions include air-conditioners, magnetic fields, and vibrations. We report a jointly developed entirely new vibration isolator which is effective against the vibrations transmitted from the floor.Conventionally, large-sized vibration isolators which need the digging of a pit have been used. These vibration isolators, however, are large present problems of installation and maintenance because of their large-size.Thus, we intended to make a vibration isolator which1) eliminates the need for changing the installation room2) eliminates the need of maintenance and3) are compact in size and easily installable.


Author(s):  
D.F. Blake ◽  
LJ. Allamandola ◽  
G. Palmer ◽  
A. Pohorille

The natural history of the biogenic elements H, C, N, O, P and S in the cosmos is of great interest because it is these elements which comprise all life. Material ejected from stars (or pre-existing in the interstellar medium) is thought to condense into diffuse bodies of gravitationally bound gas and dust called cold interstellar molecular clouds. Current theories predict that within these clouds, at temperatures of 10-100° K, gases (primarily H2O, but including CO, CO2, CH3OH, NH3, and others) condense onto submicron silicate grains to form icy grain mantles. This interstellar ice represents the earliest and most primitive association of the biogenic elements. Within these multicomponent icy mantles, pre-biotic organic compounds are formed during exposure to UV radiation. It is thought that icy planetesimals (such as comets) within our solar system contain some pristine interstellar material, including ices, and may have (during the early bombardment of the solar system, ∼4 Ga) carried this material to Earth.Despite the widespread occurrence of astrophysical ices and their importance to pre-biotic organic evolution, few experimental data exist which address the relevant phase equilibria and possible structural states. A knowledge of the petrology of astrophysical ice analogs will allow scientists to more confidently interpret astronomical IR observations. Furthermore, the development and refinement of procedures for analyzing ices and other materials at cryogenic temperatures is critical to the study of materials returned from the proposed Rosetta comet nucleus and Mars sample return missions.


Methodology ◽  
2019 ◽  
Vol 15 (3) ◽  
pp. 97-105
Author(s):  
Rodrigo Ferrer ◽  
Antonio Pardo

Abstract. In a recent paper, Ferrer and Pardo (2014) tested several distribution-based methods designed to assess when test scores obtained before and after an intervention reflect a statistically reliable change. However, we still do not know how these methods perform from the point of view of false negatives. For this purpose, we have simulated change scenarios (different effect sizes in a pre-post-test design) with distributions of different shapes and with different sample sizes. For each simulated scenario, we generated 1,000 samples. In each sample, we recorded the false-negative rate of the five distribution-based methods with the best performance from the point of view of the false positives. Our results have revealed unacceptable rates of false negatives even with effects of very large size, starting from 31.8% in an optimistic scenario (effect size of 2.0 and a normal distribution) to 99.9% in the worst scenario (effect size of 0.2 and a highly skewed distribution). Therefore, our results suggest that the widely used distribution-based methods must be applied with caution in a clinical context, because they need huge effect sizes to detect a true change. However, we made some considerations regarding the effect size and the cut-off points commonly used which allow us to be more precise in our estimates.


2020 ◽  
Vol 27 (1) ◽  
pp. 1-4
Author(s):  
Fatan Abshari ◽  
Zulfikar Ali

Objective: Transurethral lithotripsy using Holmium-YAG laser has been reported to be beneficial in breaking up bladder stones with large size (>4cm in diameter) with lower risk of mucosal injury and hematuria. The aim of this study is to evaluate the utilization of Holmium-YAG laser for the management of bladder stones at Kardinah General Hospital, Tegal. Material & Methods: This is a cross-sectional study conducted from January 2017 to March 2017. Patient’s demography, which included age, sex, length of surgery, stone size, and laser’s energy count were recorded. Results: We included 120 patients in this study. Mean of patients age in this study was 51.93 years old with age range were 41-85 years old. Most of the patients were male (109 vs 11) with a mean size of stone 25.09 ± 3.04 mm. Length of surgery ranges from 15 to 75 minutes and mean energy of the laser 28.99 ± 19.34 kJ. There was 100% stone’s clearance following surgery with no major complication occurred. Conclusion: Holmium-YAG laser is effective in managing bladder stones at Kardinah General Hospital particularly for large size stones. Length of surgery and energy of laser used depend on the stone size in which bigger stone size is associated with longer surgery time and bigger laser energy needed.


Sign in / Sign up

Export Citation Format

Share Document