Increasing the Productivity of Gas Wells in Conditions of High Water Factors

2021 ◽  
Author(s):  
Serhii Matkivskyi ◽  
Liliia Khaidarova

The overwhelming majority of natural gas fields are at the final stage of development, which, along with other features, is characterized by selective watering of productive deposits and production wells. The difficulty of extracting residual gas reserves under such development conditions is associated with depletion of productive reservoirs, accumulation of fluid at the bottom of wells, corrosion of downhole equipment and the inability to reduce wellhead pressures due to restrictions on the supply and preparation of hydrocarbon products with the existing surface infrastructure. Production wells in conditions of formation water inflow into productive deposits are decommissioned after relatively small gas withdrawals. This is due both to the insufficient implementation of methods for intensifying the removal of fluid from the bottom of the wells, and to the peculiarities of the arrangement of fields, which are usually not designed for the collection and preparation of hydrocarbon products with a high liquid content. In order to remove the gas-liquid mixture from the bottom of the wells, many techniques and inventions have been developed that are widely used in production. The developed technologies are characterized by different efficiency and have a number of technological limitations, mainly due to the peculiarities of the geological structure of hydrocarbon deposits. Considering the above, there is a need for additional research in order to improve the existing and develop new technologies for the operation of water cut wells. Using the special software package, studies were carried out to optimize the operating conditions for a water cut well under conditions of active formation water inflow into gas-saturated horizons. The study was carried out for various depths of gas-lift valves (3500 m; 3000 m; 2500 m; 2000 m; 1500 m; 1000 m) and liquid flow rates (22.5 m3/day; 33.75 m3/day and 45 m3/day). Based on the research results, graphical dependences of gas flow rates and bottomhole pressure on the amount of gas-lift gas were built; the maximum gas flow rate and the required amount of gas-lift gas from the liquid flow rate; maximum gas flow rate versus liquid flow rate at different depths of gas-lift valve installation. Based on the results of statistical processing of the calculated data for each value of the liquid flow rate, the optimal value of the depth of the gas-lift valve was established. According to the results of the studies performed, to ensure the stable operation of high-water cut gas wells, it is effective to locate the gas-lift valve at a distance of 55-58 % from the wellhead of the tubing (2033-2137 m).

Konversi ◽  
2019 ◽  
Vol 7 (1) ◽  
pp. 6
Author(s):  
Erlinda Ningsih ◽  
Abas Sato ◽  
Mochammad Alfan Nafiuddin ◽  
Wisnu Setyo Putranto

Abstract- One of the most widely used processes for CO2 gas removal is Absorption. Carbon dioxide is the result of the fuel combustion process which of the hazardous gases. The aim of this research is to determine the total mass transfer coefficient and analyze the effect of the absorbent flow rate of the absorbent solution with the promoter and the gas flow rate to the total mass transfer coefficient value. The variables consisted of liquid flow rate: 1, 2, 3, 4, 5 liter/min, gas flow rate: 15, 25, 30, 40, 50 liter/min and MSG concentration: 0%, 1%, 3% and 5% by weight. The solution of Pottasium Carbonate as absorbent with MSG promoter is flowed through top column and CO2 gas flowed from bottom packed column. Liquids were analyzed by titration and the gas output was analyzed by GC. From this research, it is found that the flow rate of gas and the liquid flow rate is directly proportional to the value of KGa. The liquid flow rate variable 5 liters / minute, gas flow rate 15 l / min obtained value of KGa 11,1102 at concentration of MSG 5%. Keywords:  Absorption, CO2,  K2CO3, MSG. 


1994 ◽  
Vol 29 (10-11) ◽  
pp. 231-241 ◽  
Author(s):  
H. T. Chang ◽  
B. E. Rittmann

This paper presents a unified model that inter-relates gas flow rate, liquid flow rate, and hold-ups of each of the liquid, gas, and solid phases in three-phase, fluidized-bed biofilm (TPFBB) process. It describes how carrier properties, biofilm properties, and gas and liquid flow velocities control the system dynamics, which ultimately will affect the density, thickness, and distribution of the biofilm. The paper describes the development of the mathematical model to correlate the effects of gas flow rate, liquid flow rate, solid concentration, and biofilm thickness and density. This knowledge is critically needed in light of the use of TPFBB processes in treating industrial wastewater, which often has high substrate concentration. For example, the proper design of the TPFBB process requires mathematical description of the cause-effect relationship between biofilm growth and fluidization.


SPE Journal ◽  
2006 ◽  
Vol 11 (02) ◽  
pp. 199-205 ◽  
Author(s):  
David I. Atkinson ◽  
Oyvind Reksten ◽  
Gerald Smith ◽  
Helge Moe

Summary Dedicated wet-gas flowmeters are now commercially available for the measurement of gas and liquid flow rates and offer a more compact measurement solution than does the traditional separator approach. The interpretation models of traditional multiphase flowmeters emphasize the liquid rate measurements and have been used to well test and meter mostly liquid-rich flow streams. These models were not developed for the measurement of gas flow rates, particularly those of wet gas. A new interpretation is described that allows a traditional multiphase flowmeter to operate in a dual mode either as a multiphase meter or as a wet-gas meter in 90 to 100% gas. The new interpretation model was developed for a commercially available multiphase flowmeter consisting of a venturi and a dual-energy composition meter. This combination results in excellent predictions of the gas flow rate; the liquid rate prediction is made with acceptable accuracy and no additional measurements. The wet gas and low-liquid-volume-fraction interpretation model is described together with the multiphase flowmeter. Examples of applying this model to data collected on flow loops are presented, with comparison to reference flow rates. The data from the Sintef and NEL flow loops show an error (including the reference meter error) in the gas flow rate, better than ± 2% reading (95% confidence interval), at line conditions; the absolute error (including the reference meter error) in the measured total liquid flow rate at line conditions was better than ± 2 m3/h (< ± 300 B/D: 95% confidence interval). This new interpretation model offers a significant advance in the metering of wet-gas multiphase flows and yields the possibility of high accuracies to meet the needs of gas-well testing and production allocation applications without the use of separators. Introduction There has been considerable focus in recent years on the development of new flow-measurement techniques for application to surface well testing and flow-measurement allocation in multiphase conditions without separating the phases. This has resulted in new technology from the industry for both gas and oil production. Today, there are wet-gas flowmeters, dedicated to the metering of wet-gas flows, and multiphase meters, for the metering of multiphase liquid flows. The common approach to wet-gas measurement relates gas and liquid flows to a "pseudo-gas flow rate" calculated from the standard single-phase equations. This addresses the need for gas measurement in the presence of liquids and can be applied to a limit of liquid flow [or gas volume fraction, (GVF)], though the accuracy of this approach decreases with decreasing GVF. The accurate determination of liquid rates by wet-gas meters is restricted in range. The application and performance of multiphase meters has been well documented through technical papers and industry forums, and after several years of development is maturing (Scheers 2004). Some multiphase measurement techniques can perform better, and the meters provide a more compact solution, than the traditional separation approach. It is not surprising that the use of multiphase flowmeters has grown significantly, the worldwide number doubling in little over a 2-year period (Mehdizadeh et al. 2002). Multiphase-flowmeter interpretation emphasizes the liquid rate measurement, and the application of multiphase flowmeters has been predominantly for liquid-rich flow stream allocation and well testing.


1989 ◽  
Vol 8 (2) ◽  
pp. 63-68
Author(s):  
A. J. Rautenbach ◽  
G. Kornelius

Spray columns are widely used in industry as a gas-liquid contacting apparatus because of the advantages of a high transfer area per unit volume and the tow gas side resistance. For a large number of systems, mass transfer parameters are not available and an experimental determination for the system benzene/wash oil was therefore carried out. The experimental technique and design are described. The variation in mass transfer coefficient as function of gas flow rate, liquid flow rate and column height agrees with those published elsewhere.


Nowadays, CO2 as the product of fossil fuel combustions, is polluting the air and the human environment, and it causes global warming. To reduce the negative effect of CO2 presence, it should be removed from the air by capturing methods. Hollow fiber membrane contactor (HFMC) system is one of the most efficient method for CO2 capturing than the other feasible capturing methods. In the present paper an HFMC absorbing system has been simulated using COMSOL Multiphysics software and the effect of flow rates of gas and liquid on the amount of CO2 removal has been studied. Aqueous solution of Mono-ethanolamine (MEA) is entered as the absorbent liquid in the tubes, and CO2 is removed from the shell side by the diffusion phenomena by participating in the chemical reaction with MEA. The results show that the higher liquid flow rate the higher %CO2 removal from the inserted gas. Against this result, the percentage of CO2 removal decreases with increasing the gas flow rate as expected. Higher gas flow rate leads the gas velocity to higher values and less possibility of absorbing by the diffusion method. The rate of the CO2 removal variation with liquid flow rate is higher than the CO2 removal variation whit the gas flow rate.


2016 ◽  
Vol 859 ◽  
pp. 153-157
Author(s):  
Pao Chi Chen ◽  
Sheng Zhong Lin

This work uses a continuous bubble-column scrubber for the absorption of CO2 with a 5M MEA solution under a constant pH environment to explore the effect of the pH of the solution and gas-flow rate (Qg) on the removal efficiency (E), absorption rate (RA), overall mass-transfer coefficient (KGa), liquid flow rate (QL), gas-liquid flow ratio (γ), and scrubbing factors (φ). From the outlet CO2 concentration with a two-film model, E, RA, KGa, QL, γ, and φ can be simultaneously determined at the steady state. Depending on the operating conditions, the results show that E (80-97%), RA(2.91x10-4-10.0x10-4mol/s-L), KGa (0.09-0.48 1/s), QL(8.74-230.8mL/min), γ (0.19-5.39), and φ (0.031-0.74 mol/mol-L) are found to be comparable with other solvents. In addition, RA, KGa, E, and QL have been used to correlate with pH and Qg, respectively, with the results further explained.


Catalysts ◽  
2018 ◽  
Vol 8 (11) ◽  
pp. 490 ◽  
Author(s):  
Rina Mariyana ◽  
Min-Sik Kim ◽  
Chae Lim ◽  
Tae Kim ◽  
Si Park ◽  
...  

The mass transfer performance of a string film reactor (SFR)—a bioreactor design for the aerobic bioconversion of methane—was investigated. The results showed that the SFR could achieve high mass transfer performance of gases, and the highest values of the mass transfer coefficients for oxygen and methane were 877.1 h−1 and 408.0 h−1, respectively. There were similar mass transfer coefficients for oxygen and methane in absorption experiments using air, methane, and air–methane mixed gas under the same liquid flow rate conditions, implying that each gas is delivered into the liquid without mutual interaction. The mass transfer performance of the SFR was significantly influenced by the liquid flow rate and the hydrophilicity of the string material, whereas the magnitude of the gas flow rate effect on the mass transfer performance depended on both the tested liquid flow rate and the gas flow rate. Furthermore, the mass transfer performance of the SFR was compared with those of other types of bioreactors.


2020 ◽  
Vol 38 (9A) ◽  
pp. 1359-1372
Author(s):  
Farah T. Al-Sudani

Absorption of CO2 into promoted-NH3 solution utilize a packed column (1.25 m long, 0.05m inside diameter) was examined in the present work. The process performance of four different blended promoters monoethanolamine (MEA)+ piperazine (PZ), piperazine (PZ)+ potassium argininate (ArgK) and monoethanolamine +potassium argininate was compared with unpromoted-NH3 solution by evaluated the absorption rate (φ_(CO_2 )) and overall mass transfer coefficient  (K_(G,CO_2.) a_v)  over the operating ranges of the studied process variables (1-15Kpa initial partial pressure of CO2, 5-15 Liter/min gas flow rate, 0.25-0.85 Liter/min liquid flow rate). The results exhibit that the absorption behavior and efficiency can be enhanced by rising volumetric liquid flow rate and initial CO2 partial pressure. However, the gas flow rate should be kept at a suitable value on the controlling gas film. Furthermore, it has been observed that the (PZ+ArgK) promoter was the major species that can accelerate the absorption rate and reached almost 66.166% up to123.23% over that of the unpromoted-NH3 solution.


Micromachines ◽  
2019 ◽  
Vol 10 (12) ◽  
pp. 807 ◽  
Author(s):  
Anaïs Becker ◽  
Christina Andrikopoulou ◽  
Pierre Bernhardt ◽  
Ruben Ocampo-Torres ◽  
Claire Trocquet ◽  
...  

This paper describes a compact microfluidic analytical device developed for the detection of low airborne formaldehyde concentrations. This microdevice was based on a three-step analysis, i.e., the passive gaseous formaldehyde uptake using a microporous membrane into an acetylacetone solution, the derivatization with acetylacetone to form 3,5-diacetyl-1,4-dihydrolutidine, and the quantification of the latter using fluorescence detection. For a rapid and easier implementation, a cylindrical geometry of the microporous element was considered to perform laboratory-controlled experiments with known formaldehyde concentrations and to establish the proof of concept. This work reports the evaluation of the uptake performance according to the microporous tube length, the liquid flow rate inside the tube, the gas flow rate outside the tube, and the gaseous formaldehyde concentration. A 10.0 cm microporous tube combined with a gas flow rate of 250 NmL/min (normal milliliters per minute) and a liquid flow rate of 17 µL/min were found to be the optimized conditions. In these experimental conditions, the fluorescence signal increased linearly with the gaseous formaldehyde concentration in the range 0–118 µg/m3, with the detection limit being estimated as 0.13 µg/m3 when considering a signal-to-noise ratio of 3.


Author(s):  
Adam Fatchur Rohman ◽  
Sugiatmo Kasmungin ◽  
Dwi Atty Mardiana

<em>The gas lift lifting system is widely used as an artificial lift on the X Field, with an average depth of gas lift production wells of 3,000-3,500 ft. Design of 3 to 5 Gas lift Valves (GLV) designwith size of 1 inch is ussualy applied. While at the point of gas injection, the GLV square edge orifice is applied. The problem in the optimization of gas lift wells is the flow instability due to gas flow rate fluctuations, the limited volumetric gas injection and limited gas compressor pressure. With the limited compressor pressure, the lift flow and gas design speed is very dependent on the amount of pressure on the compressor, the production wells with limited injection pressure will result in a limited amount of gas injection, the square edge orifice requires a pressure difference of 40% to achieve the maximum gas flow rate. This study aims to find the modification of the GLV orifice geometry to improve the efficiency of the gas lift system so that it can get optimal production. This GLV design modification includes changing the GLV orifice geometry. Design studies using Computational Fluid Dynamic (CFD) simulations aim to analyze any changes in GLV geometry design to the performance of the gas flow rate in the orifice valve described in the valve performance curve. The design modification approach is in accordance with the GLV venturi orifice geometry and the availability of equipment for GLV modification. The CFD simulation results of the first modification geometry by increasing the orifice diameter from 0.25 to 0.5 inch with the condition of upstream 650 psig and downstream 625 psig pressure increasing the injection gas flow rate capacity by 355% and modifying the second geometry with the venturi orifice form by 280%. In modifying the shape of the orifice venture to reach critical flow requires a pressure difference of 10%. Based on simulation results, the modified orifice application is able to increae production up to 44%.</em>


Sign in / Sign up

Export Citation Format

Share Document