scholarly journals Three-dimensional Digital Anatomical Measurement of Modified Sacroiliac Screws

Author(s):  
Tingguang Wang ◽  
Bei Zhao ◽  
Jun Yan ◽  
Jia Wang ◽  
Chong Chen ◽  
...  

Abstract Purpose To rebuild a model of the pelvis and effectively simulate the trajectory of modified sacroiliac screws, we measured the parameters of each screw and screw channel and assessed the safety and feasibility of the parameters in adults.Method and materials One hundred (50 males and 50 females) normal adult pelvic CT (computed tomography) images were randomly selected and imported into Mimics software to rebuild the three-dimensional pelvis model. In these models, each ideal channel of modified screws was simulated, and then we obtained the precise parameters of screws and channels using Mimics and Three-matic software.Results The results of the comparison (right vs. left) showed that there were no significant differences in any of the angles, radius or M1SI parameters (the first modified sacroiliac). However, one parameter (BS) of M2SI (the second modified sacroiliac), two parameters (AP and BS) of M3SI (the third modified sacroiliac), and three parameters (AP、BS、L) of M4SI (the fourth modified sacroiliac) were statistically significant (P < 0.05). The result of comparison (between genders) showed that there were no significant differences in M1SI and M2SI; in contrast, the radius, length and the α angle of M3SI and M4SI were significantly different between genders (P < 0.05), and the radius of M4SI required special attention. If the radius of the limiting screw channel was >3.50 mm, 52 cases (52%, 24 males and 28 females) could not complete the M4SI screw placement among 100 samples. If the radius of the limiting screw channel was >3.0 mm, a total of 10 cases (10%, 2 males and 8 females) could not complete the M4SI screw placement.Conclusion Through the measurement of 100 healthy adult real three-dimensional pelvic models, we obtained the parameters of each modified sacroiliac screw and measured the three angles of each screw based on international coordinates for the first time, which can instruct clinical application.

2020 ◽  
Author(s):  
Chao Wu ◽  
jiayan deng ◽  
jian pan ◽  
tao li ◽  
Lun Tan

Abstract Objective To analyse the anatomical conditions of transverse sacroiliac screws about the S1 and S2 segments in order to develop and validate a locked navigational template for transverse sacroiliac screw placement. Methods The CT data of 90 normal sacra were analysed. The long axis, short axis and lengths of transverse sacroiliac screw cancellous corridors were measured through 3D modelling. A patient-specific locked navigation template based on simulated screws was designed and 3D printed and then used to assist in transverse sacroiliac screw placement. The operative time, intraoperative blood loss, incision length, and radiation times were recorded. The Matta criteria and grading score were evaluated. The entry point deviation of the actual screw placement relative to the simulated screw placement was measured, and whether the whole screw was in the cancellous corridor was observed.Results S1 screws with a diameter of 7.3 mm could be inserted into 69 pelvises, and S2 screws could be inserted in all pelvises. The S1 cancellous corridor had a long axis of 25.44±3.32 mm in males and 22.91±2.46 mm in females, a short axis of 14.21±2.19 mm in males and 12.15±3.22 mm in females, a corridor length of 153.07±11.99 mm in males and 151.11±8.73 mm in females, and a proportional position of the optimal entry point in the long axis of the cancellous corridor of 35.96±10.31% in males and 33.28±7.2% in females. There were significant differences in the corridor long axis and corridor short axis between sexes (p<0.05), and there were no significant differences in corridor length and proportional position of the optimal entry point in the long axis of the cancellous corridor between sexes (p>0.05). The S2 cancellous corridor had a long axis of 17.58±2.36 mm in males and 16±2.64 mm in females, a short axis of 14.21±2.19 mm in males and 13.14±2.2 mm in females, a corridor length of 129.95±0.89 mm in males and 136.5±7.96 mm in females, and a proportional position of the optimal entry point in the long axis of the cancellous corridor of 46.77±9.02% in males and 42.25±11.95% in females. There were significant differences in the long axis, short axis and corridor length (p<0.05). There was no significant difference in the proportional position of the optimal entry point in the long axis of the cancellous corridor (p>0.05). A total of 20 transversal sacroiliac screws were successfully inserted into 10 patients with the assistance of locked navigation templates. Nineteen screws were grade 0, 1 screw was grade 1, and there were no postoperative complications of infection or nerve root injury. All screw entry point deviations were shorter than the short axis of the cancellous corridor, and all screws were located completely within the cancellous corridor.Conclusion Approximately 76% of males and females can accommodate screws with diameters of 7.3 mm in S1, and all persons can accommodate the same screw in S2. From the standard lateral perspective of the sacrum, the optimal entry point of the transverse screw is in the first 1/3 of the cancellous corridor for S1 and the centre of the cancellous corridor for S2. The patient-specific locked navigation template assisted in transverse sacroiliac screw placement with little trauma and fluoroscopy radiation and secure screw placement.


Author(s):  
T. L. Hayes

Biomedical applications of the scanning electron microscope (SEM) have increased in number quite rapidly over the last several years. Studies have been made of cells, whole mount tissue, sectioned tissue, particles, human chromosomes, microorganisms, dental enamel and skeletal material. Many of the advantages of using this instrument for such investigations come from its ability to produce images that are high in information content. Information about the chemical make-up of the specimen, its electrical properties and its three dimensional architecture all may be represented in such images. Since the biological system is distinctive in its chemistry and often spatially scaled to the resolving power of the SEM, these images are particularly useful in biomedical research.In any form of microscopy there are two parameters that together determine the usefulness of the image. One parameter is the size of the volume being studied or resolving power of the instrument and the other is the amount of information about this volume that is displayed in the image. Both parameters are important in describing the performance of a microscope. The light microscope image, for example, is rich in information content (chemical, spatial, living specimen, etc.) but is very limited in resolving power.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Angad Malhotra ◽  
Matthias Walle ◽  
Graeme R. Paul ◽  
Gisela A. Kuhn ◽  
Ralph Müller

AbstractMethods to repair bone defects arising from trauma, resection, or disease, continue to be sought after. Cyclic mechanical loading is well established to influence bone (re)modelling activity, in which bone formation and resorption are correlated to micro-scale strain. Based on this, the application of mechanical stimulation across a bone defect could improve healing. However, if ignoring the mechanical integrity of defected bone, loading regimes have a high potential to either cause damage or be ineffective. This study explores real-time finite element (rtFE) methods that use three-dimensional structural analyses from micro-computed tomography images to estimate effective peak cyclic loads in a subject-specific and time-dependent manner. It demonstrates the concept in a cyclically loaded mouse caudal vertebral bone defect model. Using rtFE analysis combined with adaptive mechanical loading, mouse bone healing was significantly improved over non-loaded controls, with no incidence of vertebral fractures. Such rtFE-driven adaptive loading regimes demonstrated here could be relevant to clinical bone defect healing scenarios, where mechanical loading can become patient-specific and more efficacious. This is achieved by accounting for initial bone defect conditions and spatio-temporal healing, both being factors that are always unique to the patient.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Wei Luo ◽  
Yuma Nakamura ◽  
Jinseon Park ◽  
Mina Yoon

AbstractRecent experiments identified Co3Sn2S2 as the first magnetic Weyl semimetal (MWSM). Using first-principles calculation with a global optimization approach, we explore the structural stabilities and topological electronic properties of cobalt (Co)-based shandite and alloys, Co3MM’X2 (M/M’ = Ge, Sn, Pb, X = S, Se, Te), and identify stable structures with different Weyl phases. Using a tight-binding model, for the first time, we reveal that the physical origin of the nodal lines of a Co-based shandite structure is the interlayer coupling between Co atoms in different Kagome layers, while the number of Weyl points and their types are mainly governed by the interaction between Co and the metal atoms, Sn, Ge, and Pb. The Co3SnPbS2 alloy exhibits two distinguished topological phases, depending on the relative positions of the Sn and Pb atoms: a three-dimensional quantum anomalous Hall metal, and a MWSM phase with anomalous Hall conductivity (~1290 Ω−1 cm−1) that is larger than that of Co2Sn2S2. Our work reveals the physical mechanism of the origination of Weyl fermions in Co-based shandite structures and proposes topological quantum states with high thermal stability.


2020 ◽  
Vol 1 (1) ◽  
pp. 62-70
Author(s):  
Amir H Sadeghi ◽  
Wouter Bakhuis ◽  
Frank Van Schaagen ◽  
Frans B S Oei ◽  
Jos A Bekkers ◽  
...  

Abstract Aims Increased complexity in cardiac surgery over the last decades necessitates more precise preoperative planning to minimize operating time, to limit the risk of complications during surgery and to aim for the best possible patient outcome. Novel, more realistic, and more immersive techniques, such as three-dimensional (3D) virtual reality (VR) could potentially contribute to the preoperative planning phase. This study shows our initial experience on the implementation of immersive VR technology as a complementary research-based imaging tool for preoperative planning in cardiothoracic surgery. In addition, essentials to set up and implement a VR platform are described. Methods Six patients who underwent cardiac surgery at the Erasmus Medical Center, Rotterdam, The Netherlands, between March 2020 and August 2020, were included, based on request by the surgeon and availability of computed tomography images. After 3D VR rendering and 3D segmentation of specific structures, the reconstruction was analysed via a head mount display. All participating surgeons (n = 5) filled out a questionnaire to evaluate the use of VR as preoperative planning tool for surgery. Conclusion Our study demonstrates that immersive 3D VR visualization of anatomy might be beneficial as a supplementary preoperative planning tool for cardiothoracic surgery, and further research on this topic may be considered to implement this innovative tool in daily clinical practice. Lay summary Over the past decades, surgery on the heart and vessels is becoming more and more complex, necessitating more precise and accurate preoperative planning. Nowadays, operative planning is feasible on flat, two-dimensional computer screens, however, requiring a lot of spatial and three-dimensional (3D) thinking of the surgeon. Since immersive 3D virtual reality (VR) is an upcoming imaging technique with promising results in other fields of surgery, we aimed in this study to explore the additional value of this technique in heart surgery. Our surgeons planned six different heart operations by visualizing computed tomography scans with a dedicated VR headset, enabling them to visualize the patient’s anatomy in an immersive and 3D environment. The outcomes of this preliminary study are positive, with a much more reality-like simulation for the surgeon. In such, VR could potentially be beneficial as a preoperative planning tool for complex heart surgery.


Author(s):  
Bardiya Akhbari ◽  
Kalpit N. Shah ◽  
Amy M. Morton ◽  
Janine Molino ◽  
Douglas C. Moore ◽  
...  

Abstract Purpose There is a lack of quantitative research that describes the alignment and, more importantly, the effects of malalignment on total wrist arthroplasty (TWA). The main goal of this pilot study was to assess the alignment of TWA components in radiographic images and compare them with measures computed by three-dimensional analysis. Using these measures, we then determined if malalignment is associated with range of motion (ROM) or clinical outcomes (PRWHE, PROMIS, QuickDash, and grip strength). Methods Six osteoarthritic patients with a single type of TWA were recruited. Radiographic images, computed tomography images, and clinical outcomes of the wrists were recorded. Using posteroanterior and lateral radiographs, alignment measurements were defined for the radial and carpal components. Radiographic measurements were validated with models reconstructed from computed tomography images using Bland–Altman analysis. Biplanar videoradiography (<1mm and <1 degree accuracy) was used to capture and compute ROM of the TWA components. Linear regression assessed the associations between alignment and outcomes. Results Radiographic measures had a 95% limit-of-agreement (mean difference ±  1.96 × SD) of 3 degrees and 3mm with three-dimensional values, except for the measures of the carpal component in the lateral view. In our small cohort, wrist flexion–extension and radial–ulnar deviation were correlated with volar–dorsal tilt and volar–dorsal offset of the radial component and demonstrated a ROM increase of 3.7 and 1.6 degrees per degree increase in volar tilt, and 10.8 and 4.2 degrees per every millimeter increase in volar offset. The carpal component's higher volar tilt was also associated with improvements in patient-reported pain. Conclusions We determined metrics describing the alignment of TWA, and found the volar tilt and volar offset of the radial component could potentially influence the replaced wrist's ROM. Clinical Relevance TWA component alignment can be measured reliably in radiographs, and may be associated with clinical outcomes. Future studies must evaluate its role in a larger cohort.


2020 ◽  
Vol 501 (1) ◽  
pp. L71-L75
Author(s):  
Cornelius Rampf ◽  
Oliver Hahn

ABSTRACT Perturbation theory is an indispensable tool for studying the cosmic large-scale structure, and establishing its limits is therefore of utmost importance. One crucial limitation of perturbation theory is shell-crossing, which is the instance when cold-dark-matter trajectories intersect for the first time. We investigate Lagrangian perturbation theory (LPT) at very high orders in the vicinity of the first shell-crossing for random initial data in a realistic three-dimensional Universe. For this, we have numerically implemented the all-order recursion relations for the matter trajectories, from which the convergence of the LPT series at shell-crossing is established. Convergence studies performed at large orders reveal the nature of the convergence-limiting singularities. These singularities are not the well-known density singularities at shell-crossing but occur at later times when LPT already ceased to provide physically meaningful results.


2009 ◽  
Vol 19 (06) ◽  
pp. 1931-1949 ◽  
Author(s):  
QIGUI YANG ◽  
KANGMING ZHANG ◽  
GUANRONG CHEN

In this paper, a modified generalized Lorenz-type system is introduced, which is state-equivalent to a simple and special form, and is parameterized by two parameters useful for chaos turning and system classification. More importantly, based on the parameterized form, two classes of new chaotic attractors are found for the first time in the literature, which are similar but nonequivalent in topological structure. To further understand the complex dynamics of the new system, some basic properties such as Lyapunov exponents, Hopf bifurcations and compound structure of the attractors are analyzed and demonstrated with careful numerical simulations.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jae-Young Kim ◽  
Michael D. Han ◽  
Kug Jin Jeon ◽  
Jong-Ki Huh ◽  
Kwang-Ho Park

Abstract Background The purpose of this study was to investigate the differences in configuration and dimensions of the anterior loop of the inferior alveolar nerve (ALIAN) in patients with and without mandibular asymmetry. Method Preoperative computed tomography images of patients who had undergone orthognathic surgery from January 2016 to December 2018 at a single institution were analyzed. Subjects were classified into two groups as “Asymmetry group” and “Symmetry group”. The distance from the most anterior and most inferior points of the ALIAN (IANant and IANinf) to the vertical and horizontal reference planes were measured (dAnt and dInf). The distance from IANant and IANinf to the mental foramen were also calculated (dAnt_MF and dInf_MF). The length of the mandibular body and symphysis area were measured. All measurements were analyzed using 3D analysis software. Results There were 57 total eligible subjects. In the Asymmetry group, dAnt and dAnt_MF on the non-deviated side were significantly longer than the deviated side (p < 0.001). dInf_MF on the non-deviated side was also significantly longer than the deviated side (p = 0.001). Mandibular body length was significantly longer on the non-deviated side (p < 0.001). There was no significant difference in length in the symphysis area (p = 0.623). In the Symmetry group, there was no difference between the left and right sides for all variables. Conclusion In asymmetric patients, there is a difference tendency in the ALIAN between the deviated and non-deviated sides. In patients with mandibular asymmetry, this should be considered during surgery in the anterior mandible.


Sign in / Sign up

Export Citation Format

Share Document