scholarly journals Research on the effect of the size of the wall-hanging air-conditioner indoor unit on the indoor thermal comfort

2020 ◽  
Author(s):  
Kuanbing Caozhu ◽  
Changfa Ji

Abstract The geometrical dimension of the wall-hanging air-conditioner indoor unit affects the indoor thermal comfort. In this paper, fluent software is used and standard k-e two equation turbulent model is chosen to carry out the simulation of the indoor temperature field and flow field of six different sizes of the single wall-hanging indoor air-conditioner in the room. The temperature distribution, velocity distribution and PMV distribution of the plane which is 1.8 m from the ground are given. It can be known that under the condition of six kinds of sizes of the wall-hanging air-conditioner indoor unit, when the size of the air-conditioner indoor unit is 0.4m × 0.2m × 0.2 m, the temperature variation at the z = 1.8 m section is relatively small, the temperature distribution is more uniform. When the size of the air-conditioner indoor unit is 0.5m × 0.2m × 0.2 m, the temperature difference at the z = 1.8 m section is relatively smaller, PMV is closest to 0, and the thermal sensation is almost moderate. Therefore when the size of the air-conditioner indoor unit is 0.5m × 0.2m × 0.2 m, better indoor comfort can be achieved.

2020 ◽  
pp. 1420326X2092552
Author(s):  
Yang Zhang ◽  
Wenxuan Yu ◽  
Youli Li ◽  
Han Li

In this article, a comparative study on the outdoor air pollutant prevention and indoor thermal comfort for different types of ventilation was carried out. Both objective experiment, subjective experiment and computational fluid dynamics (CFD) simulation were conducted to investigate the differences in air pollutant prevention and thermal comfort between four common ventilation methods, namely supplying on the ceiling and returning on the ceiling (SC-RC), supplying on the ceiling and returning on the side wall (SC-RSW), supplying on the side wall and returning on the ceiling (SSW-RC), and supplying on the side wall and returning on the side wall (SSW-RSW). Results show that SSW-RSW can provide the highest indoor air quality according to the indoor average PM2.5 concentration. Overall thermal sensation was introduced to evaluate the indoor comfort under the four ventilation methods. The voting results show that the indoor thermal comfort can be enhanced by 29–36% under SSW-RSW and SSW-RC. Therefore, SSW-RSW is more suitable for providing a healthy and comfortable indoor environment.


Urban Science ◽  
2021 ◽  
Vol 5 (3) ◽  
pp. 53
Author(s):  
Haven Hailu ◽  
Eshetu Gelan ◽  
Yared Girma

Indoor thermal comfort is an essential aspect of sustainable architecture and it is critical in maintaining a safe indoor environment. Expectations, acceptability, and preferences of traditional and modern buildings are different in terms of thermal comfort. This study, therefore, attempts to evaluate the indoor thermal comforts of modern and traditional buildings and identify the contributing factors that impede or facilitate indoor thermal comfort in Semera city, Ethiopia. This study employed subjective and objective measurements. The subjective measurement is based on the ASHRAE seven-point thermal sensation scale. An adaptive comfort model was employed according to the ASHRAE standard to evaluate indoor thermal comfort. The results revealed that with regards to thermal sensational votes between −1 and +1, 88% of the respondents are satisfied with the indoor environment in traditional houses, while in modern houses this figure is 22%. Likewise, 83% of occupants in traditional houses expressed a preference for their homes to remain the same or be only slightly cooler or warmer. Traditional houses were, on average, in compliance with the 80% acceptability band of the adaptive comfort standard. The study investigated that traditional building techniques and materials, in combination with consideration of microclimate, were found to play a significant role in regulating the indoor environment.


2020 ◽  
pp. 014459872096921
Author(s):  
Yanru Li ◽  
Enshen Long ◽  
Lili Zhang ◽  
Xiangyu Dong ◽  
Suo Wang

In the Yangtze River zone of China, the heating operation in buildings is mainly part-time and part-space, which could affect the indoor thermal comfort while making the thermal process of building envelope different. This paper proposed to integrate phase change material (PCM) to building walls to increase the indoor thermal comfort and attenuate the temperature fluctuations during intermittent heating. The aim of this study is to investigate the influence of this kind of composite phase change wall (composite-PCW) on the indoor thermal environment and energy consumption of intermittent heating, and further develop an optimization strategy of intermittent heating operation by using EnergyPlus simulation. Results show that the indoor air temperature of the building with the composite-PCW was 2–3°C higher than the building with the reference wall (normal foamed concrete wall) during the heating-off process. Moreover, the indoor air temperature was higher than 18°C and the mean radiation temperature was above 20°C in the first 1 h after stopping heating. Under the optimized operation condition of turning off the heating device 1 h in advance, the heat release process of the composite-PCW to the indoor environment could maintain the indoor thermal environment within the comfortable range effectively. The composite-PCW could decrease 4.74% of the yearly heating energy consumption compared with the reference wall. The optimization described can provide useful information and guidance for the energy saving of intermittently heated buildings.


Technologies ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 90
Author(s):  
Siliang Lu ◽  
Erica Cochran Hameen

Heating, ventilation and air-conditioning (HVAC) systems play a key role in shaping office environments. However, open-plan office buildings nowadays are also faced with problems like unnecessary energy waste and an unsatisfactory shared indoor thermal environment. Therefore, it is significant to develop a new paradigm of an HVAC system framework so that everyone could work under their preferred thermal environment and the system can achieve higher energy efficiency such as task ambient conditioning system (TAC). However, current task conditioning systems are not responsive to personal thermal comfort dynamically. Hence, this research aims to develop a dynamic task conditioning system featuring personal thermal comfort models with machine learning and the wireless non-intrusive sensing system. In order to evaluate the proposed task conditioning system performance, a field study was conducted in a shared office space in Shanghai from July to August. As a result, personal thermal comfort models with indoor air temperature, relative humidity and cheek (side face) skin temperature have better performances than baseline models with indoor air temperature only. Moreover, compared to personal thermal satisfaction predictions, 90% of subjects have better performances in thermal sensation predictions. Therefore, personal thermal comfort models could be further implemented into the task conditioning control of TAC systems.


Author(s):  
Xiao Chen ◽  
Qian Wang

This paper proposes a model predictive controller (MPC) using a data-driven thermal sensation model for indoor thermal comfort and energy optimization. The uniqueness of this empirical thermal sensation model lies in that it uses feedback from occupants (occupant actual votes) to improve the accuracy of model prediction. We evaluated the performance of our controller by comparing it with other MPC controllers developed using the Predicted Mean Vote (PMV) model as thermal comfort index. The simulation results demonstrate that in general our controller achieves a comparable level of energy consumption and comfort while eases the computation demand posed by using the PMV model in the MPC formulation. It is also worth pointing out that since we assume that our controller receives occupant feedback (votes) on thermal comfort, we do not need to monitor the parameters such as relative humidity, air velocity, mean radiant temperature and occupant clothing level changes which are necessary in the computation of PMV index. Furthermore simulations show that in cases where occupants’ actual sensation votes might deviate from the PMV predictions (i.e., a bias associated with PMV), our controller has the potential to outperform the PMV based MPC controller by providing a better indoor thermal comfort.


2021 ◽  
Vol 11 (18) ◽  
pp. 8565
Author(s):  
Jinzhe Nie ◽  
Yuxin Pang ◽  
Congcong Wang ◽  
Han Zhang ◽  
Kuichao Yin

In the field investigation of rural dwellings, it was found that thermal feelings are significantly different with varied envelopes even under the same indoor air temperature, and this paper explores the phenomenon in simulation. Based on building thermal investigations in several villages of North China, a typical energy and environment simulation model for rural residences was developed using DeST, and the hourly parameters of temperature and humidity were used to calculate the adaptive thermal comfort (APMV) of the rooms. The results show that the main reason for the different thermal comfort at the same air temperature is the large difference in the inner surface temperature. By adjusting the insulation thickness of the envelope structure, the relationship between it and the APMV value is obtained. By adjusting the insulation thickness of the enclosure structure and getting the correlation between it and the APMV value, it is obtained that when the heat transfer coefficient of the enclosure structure meets 0.5 W/ (m2−K), the indoors can be in thermal comfort. This paper considers that the indoor air temperature cannot represent the APMV to evaluate the indoor thermal comfort, and the APMV value should be used to evaluate the thermal comfort of the renovated building and calculate the corresponding energy saving rate.


2021 ◽  
Vol 246 ◽  
pp. 15003
Author(s):  
Natalia Krawczyk

Nowadays, we spend most of our time inside buildings. Thus, ensuring adequate thermal comfort is an important issue. The paper discusses the issue of thermal comfort assessment in the intelligent low energy building “Energis” of Kielce University of Technology (Poland). The tests conducted in a selected lecture theater focused on collecting anonymous questionnaires containing thermal sensation and air quality votes of the respondents as well as performing measurements of indoor air parameters (air and globe temperatures, relative humidity, air velocity and CO2 concentration). Based on the obtained data a comparison has been done between the actual sensation votes of the volunteers and the calculation results performed with the Fanger thermal comfort model. Two indices have been considered in the paper: PMV (Predicted Mean Vote) and PPD (Predicted Percentage Dissatisfied). A modification of the model has also been proposed, which considers the impact of the carbon dioxide concentration on thermal comfort.


Energies ◽  
2020 ◽  
Vol 13 (22) ◽  
pp. 5958
Author(s):  
Fusheng Ma ◽  
Changhong Zhan ◽  
Xiaoyang Xu ◽  
Guanghao Li

In Northeast China, most classrooms in primary and secondary schools still use natural ventilation during cold days in winter. This study investigated the thermal comfort and the perceived air quality of children in primary schools in severe cold regions in China. Field measurements were conducted in four typical primary classrooms in two naturally ventilated teaching buildings in the winter of 2016 in the provincial city of Shenyang. Six field surveys were distributed to 141 primary students aged 8 to 11, and 835 valid questionnaires were collected. The results showed that the indoor temperature and the daily mean CO2 concentrations of the primary school classrooms ranged from 17.06 to 24.29 °C and from 1701 to 3959 ppm, respectively. The thermal neutral temperature of the primary school students was 18.5 °C, and the 90% thermal comfort temperature ranged from 17.3 to 20.1 °C. Children were able to respond to changes in indoor air quality, but there was no significant correlation between the children’s perceptions of air quality and the carbon dioxide levels in the classroom. In general, children have a lower comfort temperature than adults. In addition, children are more sensitive to temperature changes during the heating season than adults. Due to differences in thermal sensation between children and adults, the current thermal comfort standard based on adult data is not applicable to primary school buildings and children. The air quality evaluation during heating season indicates that it is necessary to add indoor air environment monitoring instruments and purification equipment to the naturally ventilated classrooms. At present and in the future, more research based on children’s data is needed to solve the indoor air environment problems in primary school buildings.


2019 ◽  
Vol 11 (18) ◽  
pp. 5091 ◽  
Author(s):  
Mun ◽  
Kwak ◽  
Kim ◽  
Huh

In this study a quantitative analysis was performed on the effect on thermal comfort of the stand fan, a personal cooling device that creates local air currents. A total of 20 environmental conditions (indoor temperatures: 22, 24, 26, 28, and 30°C; fan modes: off, low (L) mode, medium (M) mode, and high (H) mode) were analyzed using questionnaires on male and female subjects in their 20s and a thermal manikin test. The contents of the questionnaire consisted of items on thermal sensation, thermal comfort, thermal acceptability, and demands on changes to the air velocity. This step was accompanied by the thermal manikin test to analyze the convective heat transfer coefficient and cooling effect quantitatively by replicating the stand fan. Given that this study provides data on the cooling effect of the stand fan in quantitative values, it allows for a comparison of energy use with other cooling systems such as the air conditioner, and may be used as a primary data set for analysis of energy conservation rates.


2013 ◽  
Vol 805-806 ◽  
pp. 1620-1624 ◽  
Author(s):  
Wan Ying Qu

A thermal comfort field study was investigated in residential buildings of cold regions in transition season during which the indoor thermal environment conditions are measured, the thermal sensation value of the occupants is questioned and recorded. A seven-point thermal sensation scale was used to evaluate the thermal sensation. The statistical method was used to analyze the data and the conclusions are as follows in transition season: clothing increase in 0.1clo when the indoor air temperature is lowered by 1°C; and clothing will be a corresponding increase in 0.06clo when the outdoor air temperature is lowered by 1°C; clothing also varies with gender, age, weight and thermal history and other related; the measured thermal neutral temperature is 21.3°C; and the minimum accepted temperature is 11.4 °C in transition season in cold regions. Most people choose to change clothes, switch and other passive measures, and occasionally take active measures of heater, electric fans and others.


Sign in / Sign up

Export Citation Format

Share Document