scholarly journals CT Measurement of Proximal Femoral Medullary Cavity Morphology in Healthy Subjects from Northern China

2020 ◽  
Author(s):  
Ran Zhao ◽  
Hong Cai ◽  
Ke Zhang ◽  
Hua Tian

Abstract Purpose: In total hip arthroplasty (THA), optimal stability and fixation is achieved via tight adaptation of the prosthesis to the bone. This study aimed to analyze the proximal femoral medullary cavity morphology of Chinese subjects on three-dimensional reconstructed imagery to explore the factors influencing these parameters.Methods: CT was performed on 63 healthy subjects from northern China (94 hips; 31 men, 63 women). Three-dimensional CT reconstruction of the proximal femoral medullary cavity was performed using Mimics 22.0 software. The anatomical parameters related to THA were measured to examine the relationships between sex, age, and femoral length. These parameters were compared with previously published data.Results: The internal and external coronal diameters of the femoral medullary cavity, and the anterior and posterior sagittal diameters had different contracting trends. There were correlations between the femoral length, femoral head diameter, and coronal diameter, and between the sagittal diameter and cross-sectional area of the medullary cavity. Age was negatively correlated with the CFI(canal flare index). Sex was correlated with the cross-sectional coronal/sagittal diameters, but not with the canal flare index. The proximal end of the medullary cavity was similar to that reported in Caucasians, but the Asian medullary cavity was narrower distal to the level of the lesser trochanteric line.Conclusions: THA-related anatomy was affected by sex, age, and subpopulation. Compared with sex, age had a greater effect on the fit of the stem to the femoral canal. Each patient must be treated individually, as the anatomical structure varied between individuals.

2020 ◽  
Author(s):  
Ran Zhao ◽  
Hong Cai ◽  
Hua Tian ◽  
Ke Zhang

Abstract Background In total hip arthroplasty (THA), optimal stability and fixation is achieved via tight adaptation of the prosthesis to the bone. This study aimed to analyze the proximal femoral medullary cavity morphology of Chinese subjects on three-dimensional reconstructed imagery to explore the factors influencing these parameters. Methods CT was performed on 63 healthy subjects from northern China (94 hips; 31 men, 63 women). Three-dimensional CT reconstruction of the proximal femoral medullary cavity was performed using Mimics 22.0 software. The anatomical parameters related to THA were measured to examine the relationships between sex, age, and femoral length. These parameters were compared with previously published data. Results The internal and external coronal diameters of the femoral medullary cavity, and the anterior and posterior sagittal diameters had different contracting trends. There were correlations between the femoral length, femoral head diameter, and coronal diameter, and between the sagittal diameter and cross-sectional area of the medullary cavity. Age was negatively correlated with the CFI. Sex was correlated with the cross-sectional coronal/sagittal diameters, but not with the canal flare index. The proximal end of the medullary cavity was similar to that reported in Caucasians, but the Asian medullary cavity was narrower distal to the level of the lesser trochanteric line. Conclusion THA-related anatomy was affected by sex, age, and subpopulation. Compared with sex, age had a greater effect on the fit of the stem to the femoral canal. Each patient must be treated individually, as the anatomical structure varied between individuals.


2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Xiu-Yun Su ◽  
Zhe Zhao ◽  
Jing-Xin Zhao ◽  
Li-Cheng Zhang ◽  
An-Hua Long ◽  
...  

Purpose. The human femur has long been considered to have an anatomical anterior curvature in the sagittal plane. We established a new method to evaluate the femoral curvature in three-dimensional (3D) space and reveal its influencing factors in Chinese population. Methods. 3D models of 426 femurs and the medullary canal were constructed using Mimics software. We standardized the positions of all femurs using 3ds Max software. After measuring the anatomical parameters, including the radius of femoral curvature (RFC) and banking angle, of the femurs using the established femur-specific coordinate system, we analyzed and determined the relationships between the anatomical parameters of the femur and the general characteristics of the population. Results. Pearson’s correlation analyses showed that there were positive correlations between the RFC and height (r=0.339, p<0.001) and the femoral length and RFC (r=0.369, p<0.001) and a negative correlation between the femoral length and banking angle (r=-0.223, p<0.001). Stepwise linear regression analyses showed that the most relevant factors for the RFC and banking angle were the femoral length and gender, respectively. Conclusions. This study concluded that the banking angle of the femur was significantly larger in female than in male.


2021 ◽  
Vol 20 ◽  
pp. e219912
Author(s):  
Victor Nogueira Moura ◽  
Emerson Nogueira ◽  
Ewerton Daniel Rocha Rodrigues ◽  
Caio Gonçalves Silva ◽  
Ricardo José De Holanda Vasconcellos

Aim: Evaluation of the reliability of 3D computed tomography (3D-CT) in the diagnosis of mandibular fractures. Methods: A cross-sectional, quantitative and qualitative study was carried out, through the application of a questionnaire for 70 professionals in the area of Oral and Maxillofacial Surgery and Radiology. 3D-CT images of mandibular fractures were delivered to the interviewees along with a questionnaire. Participants answered about the number of traces, the region and the type of fracture. The correct diagnosis, that is, the expected answer, was based on the reports of a specialist in oral and maxillofacial radiology after viewing the images in the axial, sagittal and coronal sections. The resulting data from the interviewees was compared with the expected answer and then, the data was analyzed statistically. Results: In the sample 56.9% were between 22 and 30 years old, 52.8% were oral and maxillofacial surgeons (OMF), 34.7% were residents in OMF surgery and 12.5% OMF radiologists. Each professional answered 15 questions (related to five patients) and 50.8% of the total of these was answered correctly. Specialists in Oral and Maxillofacial Surgery and Traumatology correctly answered 53.9%. Interviewees with experience between 6 and 10 years correctly answered 58.2%. In identifying fracture traces, 46.1% of the questions were answered correctly. In terms of location, 5.6% of interviewees answered wrongly while 14.2% answered wrongly regarding classification. Conclusion: 3D computed tomography did not prove to be a reliable image for diagnosing mandibular fractures when used alone. This made necessary an association with axial, sagittal and coronal tomographic sections.


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Yang Liu ◽  
Aobo Zhang ◽  
Rui Cai ◽  
Hao Chen ◽  
Chen Li ◽  
...  

Purpose. The femoral anterior bow is an important factor in matching a femoral implant to a femur. However, its morphology in the Chinese population has rarely been reported. In this study, a three-dimensional measurement approach was adopted to provide accurate data. The aim was to supply a reference for designing a long-stemmed femoral prosthesis that is more suitable for Chinese people. Methods. Computed tomography data were collected from both lower limbs of 96 normal volunteers and reconstructed into a three-dimensional model using Mimics software. The parameters of the femoral anterior bow were measured using medical image analysis software. Statistical analysis was conducted using independent-samples and paired-samples t -tests with SPSS software. Results. All the indexes showed significant sexual difference ( P < 0.05 ). The minimum cross-sectional area of the femoral medullary cavity was larger in men ( 10.77 ± 1.53  mm) than in women ( 9.79 ± 1.27  mm). The distance from the position of the maximum curvature to the lower edge of the lesser trochanter was also larger in men ( 60.93 ± 5.81  mm) than in women ( 56.31 ± 2.80  mm). However, the curvature of the femoral medullary cavity centerline was larger in women ( 883.57 ± 249.74  mm) than in men ( 958.79 ± 266.61  mm). The femoral anterior bow morphological indexes of Chinese subjects were different from the published data for other populations. There were no significant differences between left and right femoral anterior bows in either sex ( P > 0.05 ). Conclusion. The three-dimensional measurement approach adopted in this study is more convenient and accurate than previous conventional methods, with high repeatability. The morphological indexes of the femoral anterior bow in this research suggest that population characteristics should be taken into account. This study will provide references for the design of long-stemmed femoral prostheses in the Chinese population.


Author(s):  
Abdulrahman M. Ibrahem ◽  
Salah Q. Mahmood ◽  
Muhammed Babakir-Mina ◽  
Salar Ibrahim Ali ◽  
Bakhtyar Kamal Talabany

Knowledge and practice of public, especially patients about eye diseases are important to reduce magnitude of human blindness. Vision and sight are very essential because they allow us to connect to each other’s. In accordance to the recently published data; the estimation of 253 million people lives with vision impairment, 36 million are blind and 217 million suffer from moderate to severe vision impairment. A descriptive cross-sectional study was conducted at Shahid Dr. Aso Hospital in Sulaimani city-Iraq, from April to August 2017 by face-to-face interview through close ended questionnaire for data collecting. All data were analyzed by Statistical Package for Social Sciences version 22.0 software. P-value of < 0.05 was considered as a statistically significant. A total of 430 patients were randomly chosen to participate in the study. They were 254 (59.1%) males and 176 (40.9%) females. 76.7% of respondents was worrying about vision loss, 0.7% was worrying about hair loss. Of the participants, 32.8% was with a good knowledge level and 40.5% was with a poor knowledge level, as well as 3.1% was in a good practice and 58.8% was in a poor practice level. Female knowledge mean score was 9.53±4.96 and male knowledge mean score was 8.42±5.45, the practice mean score of males was 4.33±1.96 and mean practice score of females was 4.13±1.93. The study data indicate the worrying of participates about vision loss is in the highest proportion and the awareness and practice of patients about eye diseases is unsatisfactory. Health education campaigns are needed to improve personal awareness about vision related problems and for better eye health.


Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 757
Author(s):  
Maged Sultan Alhammadi ◽  
Abeer Abdulkareem Al-mashraqi ◽  
Rayid Hussain Alnami ◽  
Nawaf Mohammad Ashqar ◽  
Omar Hassan Alamir ◽  
...  

The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18–30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland–Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.


2021 ◽  
Vol 11 (8) ◽  
pp. 3404
Author(s):  
Majid Hejazian ◽  
Eugeniu Balaur ◽  
Brian Abbey

Microfluidic devices which integrate both rapid mixing and liquid jetting for sample delivery are an emerging solution for studying molecular dynamics via X-ray diffraction. Here we use finite element modelling to investigate the efficiency and time-resolution achievable using microfluidic mixers within the parameter range required for producing stable liquid jets. Three-dimensional simulations, validated by experimental data, are used to determine the velocity and concentration distribution within these devices. The results show that by adopting a serpentine geometry, it is possible to induce chaotic mixing, which effectively reduces the time required to achieve a homogeneous mixture for sample delivery. Further, we investigate the effect of flow rate and the mixer microchannel size on the mixing efficiency and minimum time required for complete mixing of the two solutions whilst maintaining a stable jet. In general, we find that the smaller the cross-sectional area of the mixer microchannel, the shorter the time needed to achieve homogeneous mixing for a given flow rate. The results of these simulations will form the basis for optimised designs enabling the study of molecular dynamics occurring on millisecond timescales using integrated mix-and-inject microfluidic devices.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Zhe Li ◽  
Guanzhi Liu ◽  
Run Tian ◽  
Ning Kong ◽  
Yue Li ◽  
...  

Abstract Background Our objective was to obtain normal patellofemoral measurements to analyse sex and individual differences. In addition, the absolute values and indices of tibial tuberosity-trochlear groove (TT-TG) distances are still controversial in clinical application. A better method to enable precise prediction is still needed. Methods Seventy-eight knees of 78 participants without knee pathologies were included in this cross-sectional study. A CT scan was conducted for all participants and three-dimensional knee models were constructed using Mimics and SolidWorks software. We measured and analysed 19 parameters including the TT-TG distance and dimensions and shapes of the patella, femur, tibia, and trochlea. LASSO regression was used to predict the normal TT-TG distances. Results The dimensional parameters, TT-TG distance, and femoral aspect ratio of the men were significantly larger than those of women (all p values < 0.05). However, after controlling for the bias from age, height, and weight, there were no significant differences in TT-TG distances and anterior-posterior dimensions between the sexes (all p values > 0.05). The Pearson correlation coefficients between the anterior femoral offset and other indexes were consistently below 0.3, indicating no relationship or a weak relationship. Similar results were observed for the sulcus angle and the Wiberg index. Using LASSO regression, we obtained four parameters to predict the TT-TG distance (R2 = 0.5612, p < 0.01) to achieve the optimal accuracy and convenience. Conclusions Normative data of patellofemoral morphology were provided for the Chinese population. The anterior-posterior dimensions of the women were thicker than those of men for the same medial-lateral dimensions. More attention should be paid to not only sex differences but also individual differences, especially the anterior condyle and trochlea. In addition, this study provided a new method to predict TT-TG distances accurately.


Author(s):  
Ran Zhao ◽  
Hong Cai ◽  
Hua Tian ◽  
Ke Zhang

Abstract Purpose The application of the anatomical parameters of the contralateral hip joint to guide the preoperative template of the affected side relies on the bilateral hip symmetry. We investigated the bilateral hip symmetry and range of anatomical variations by measurement and comparison of bilateral hip anatomical parameters. Methods This study included 224 patients (448 hips) who were diagnosed with osteoarthritis (OA) and avascular necrosis (AVN) of the femur head, and underwent bilateral primary total hip arthroplasty (THA) in our hospital from January 2012 to August 2020. Imaging data included 224 patients X-ray and 30 CT data at the end of the cohort. Anatomical parameters, including the acetabular abduction angle and trochanteric height, were measured using the Noble method. Postoperative measurements included stem size, difference of leg length and offset. Results Except for the isthmus width, there were no significant differences in the anatomical morphology of the hip joint. Among the demographic factors, there was a correlation between body weight and NSA. Among various anatomical parameters, a correlation was present between medullary cavity widths of T + 20, T, and T − 20. The difference in the use of stem size is not due to the morphological difference of bilateral medullary cavity, but due to the different of 1- or 2-stage surgery. Conclusion Bilateral symmetry was present among the patients with normal morphology of the hip medullary cavity, theoretically confirming the feasibility of structural reconstruction of the hip joint using the hip joint on the uninjured side. Additionally, the difference in the morphology of the hip medullary cavity is not present in a single plane but is synergistically affected by multiple adjacent planes.


Sign in / Sign up

Export Citation Format

Share Document