scholarly journals Reliability-based optimization of water distribution networks

Author(s):  
Nikita Palod ◽  
Vishnu Prasad ◽  
Ruchi Khare

Abstract The water distribution system serves as a basic necessity for society. Due to its large size and involvement of various components, it is one of the most expensive civil infrastructures and thus demands optimization. Much work has been done for reducing the distribution system cost. However, with only one objective, the obtained solutions may not be practical to implement. Thus, improving cost along with the efficiency of the network is the demand of the hour. The present work introduces a unique parameter-less methodology for generating Pareto fronts without involving the concept of non-dominance. The methodology incorporates the Jaya optimization model for a bi-objective problem, one being the reduction in network cost and the other is improving the reliability index of the network. The efficiency of the proposed work is analyzed for three different benchmark problems. The Jaya technique is found to be very efficient and fast when compared with the other evolutionary technique applied for the same networks. The parameter-less nature of the Jaya technique smoothens the process to a very large extent as no synchronization of algorithm parameters is required.

2020 ◽  
Vol 21 (2) ◽  
pp. 227-235
Author(s):  
Muhammad Rizki Apritama ◽  
I Wayan Koko Suryawan ◽  
Yosef Adicita

ABSTRACTThe clean water supply system network on Lengkang Kecil Island was developed in 2019. A small portion of the community's freshwater comes from harvesting rainwater and dug wells, which are only obtained during the rainy season. The primary source of clean water used by the community comes from underwater pipelines with a daily discharge of 0.86 l/sec. The water supply of the Lengkang Kecil Island community is 74.3 m3/day, with 146 House Connections (HCs) and to serve public facilities such as elementary schools, primary health centers, and mosques. Hydraulic evaluation of clean water distribution using EPANET 2.0 software on flow velocity shows the lowest rate of 0.29 m/s and the highest of 1.21 m/s. The lowest pressure value in the distribution system is 6.94-6.96 m and headloss units in the range 0.08-0.25 m/km. These three criteria are still within the distribution network design criteria (feasible). A carbon footprint can be calculated from each activity from the analysis of the evaluation of clean water distribution networks. The most massive emissions came from pumping activities with 131 kg CO2-eq, followed by emissions from wastewater 62.5 kgCO2-eq. Further research is needed to determine the quality of wastewater and the design for a centralized wastewater treatment plant (IPALT) to improve Lengkang Kecil Island residents' living standards.Keywords: Lengkang Kecil Island, water, EPANET, carbon footprintABSTRAKJaringan sistem penyediaan air bersih pada Pulau Lengkang Kecil dimulai pada tahun 2019. Sebagian kecil air bersih yang digunakan masyarakat berasal dari pemanenan air hujan dan sumur gali yang hanya didapat pada musim hujan. Sumber air bersih utama yang digunakan masyarakat berasal dari pengaliran perpipaan bawah laut dengan debit harian 0,86 l/detik. Kebutuhan air masyarakat Pulau Lengkang Kecil adalah 74,3 m3/hari dengan 146 Sambungan Rumah (SR) serta untuk melayani fasilitas umum seperti sekolah dasar (SD), puskesmas, dan masjid. Evaluasi hidrolis distribusi air bersih dengan menggunakan software EPANET 2.0 terhadap kriteria kecepatan aliran menunjukkan nilai terendah 0,29 m/s dan tertinggi 1,21 m/s. Nilai sisa tekan dalam sistem distribusi adalah 6,94–6,96 m dan unit headloss pada kisaran 0,08–0,25 m/km. Ketiga kriteria ini masih berada dalam kriteria desain jaringan distribusi (layak). Dari analisis evaluasi jaringan distribusi air bersih, dapat dihitung jejak karbon yang dihasilkan dari setiap kegiatannya. Emisi terbesar berasal dari kegiatan pemompaan dengan nilai 131 kgCO2-eq, diikuti dengan emisi yang berasal dari air limbah dengan nilai 62,5 kgCO2-eq. Penelitian lanjutan diperlukan untuk mengetahui kualitas dari air limbah dan desain untuk instalasi pengolahan air limbah terpusat (IPALT) untuk meningkatkan taraf hidup penduduk Pulau Lengkang Kecil.Kata kunci: Pulau Lengkang Kecil, air, EPANET, jejak karbon


Energies ◽  
2020 ◽  
Vol 13 (10) ◽  
pp. 2530 ◽  
Author(s):  
Luigi Cimorelli ◽  
Carmine Covelli ◽  
Bruno Molino ◽  
Domenico Pianese

Greenhouse gas emission is one of the main environmental issues of today, and energy savings in all industries contribute to reducing energy demand, implying, in turn, less carbon emissions into the atmosphere. In this framework, water pumping systems are one of the most energy-consuming activities. The optimal regulation of pumping systems with the use of variable speed drives is gaining the attention of designers and managing authorities. However, optimal management and operation of pumping systems is often performed, employing variable speed drives without considering if the energy savings are enough to justify their purchasing and installation costs. In this paper, the authors compare two optimal pump scheduling techniques, optimal regulation of constant speed pumps by an optimal ON/OFF sequence and optimal regulation with a variable speed pump. Much of the attention is devoted to the analysis of the costs involved in a hypothetical managing authority for the water distribution system in order to determine whether the savings in operating costs is enough to justify the employment of variable speed drives.


2019 ◽  
Vol 63 (4) ◽  
pp. 295-300 ◽  
Author(s):  
Tamás Huzsvár ◽  
Richárd Wéber ◽  
Csaba János Hős

One of the basic infrastructures of every settlement is the water distribution system, which provides clean and potable water for both private houses, industrial consumers and institution establishments. The operational robustness and vulnerabilities of these networks is an essential issue, both for the quality of life and for the preservation of the environment. Even with frequent and careful maintenance, unintentional pipe bursts might occur, and during the reparation time, the damaged section must be isolated hydraulically from the main body of the water distribution network. Due to the size and complexity of these networks, it might not be trivial how to isolate the burst section, especially if one wishes to minimize the impact on the overall system. This paper presents an algorithmic method that is capable of creating isolation plans for real-life networks in a computationally efficient way, based on the graph properties of the network. Besides this segmentation plan, the topological behavior of the structural graph properties was analyzed with the help of the complex network theory to create a method for the quantitative topology based categorization of the water distribution networks.


Author(s):  
Attila Bibok ◽  
Roland Fülöp

Pressure management is a widely adopted technique in the toolset of drinking water distribution system operators. It has multiple benefits, like reducing physical losses in pipe networks with excessive leakage, prolong the expected lifetime of the pipes and protecting home appliances from unacceptably high pressure. In some cases, even legislation compliance can be the motivation behind pressure management: It is mandatory to supply water at the customer’s connection between 1.5 and 6.0 bar in Hungary since 2011. Diaphragm pressure reducing valves are widespread in the drinking water distribution networks. Although, their sensitivity for gas pocket accumulation in the valve house makes hydraulic calibration of these pressure managed areas a challenging task for hydraulic modelers and network operators. This is especially true when more than one inlet is used to supply the same area in order to increase resilience and flow capacity.This paper investigates the hydraulic properties of pressure reduced areas with multiple inlet points. Model calibration using a single valve and minor loss was found insufficient because the additional pressure loss referenced to the pressure setting has a non-quadratic relationship with flow-rate on the discharge side under real-life circumstances. This phenomenon can be handled by using a PRV (pressure reducing valve) + GPV (general purpose valve) in series.


2013 ◽  
Vol 13 (5) ◽  
pp. 1367-1376 ◽  
Author(s):  
J. G. Bene ◽  
I. Selek ◽  
Cs. Hős

This paper presents a novel approximate dynamic programming technique for solving the pump schedule optimization of real-water distribution networks. The method is based on the significant decreasing of the search space by splitting the optimization problem into smaller units. In addition, the state space of the main distribution system was further reduced to the most important reservoirs. The capabilities of the proposed technique are demonstrated on a real-life problem, the water distribution system of the town of Sopron, Hungary. Nine test cases were defined which represent different initial water level scenarios, thus the new application was easy to compare to a former developed genetic algorithm and to some world-leading optimization solvers which are available on the NEOS Server. The benefits and drawbacks of these deterministic and heuristic methods are highlighted.


2014 ◽  
Vol 17 (1) ◽  
pp. 20-35 ◽  
Author(s):  
João Marques ◽  
Maria Cunha ◽  
Dragan A. Savić

This paper presents a real options approach to handling uncertainties associated with the long-term planning of water distribution system development. Furthermore, carbon emissions associated with the installation and operation of water distribution networks are considered. These emissions are computed by taking an embodied energy approach to the different materials used in water networks. A simulated annealing heuristic is used to optimise a flexible eco-friendly design of water distribution systems for an extended life horizon. This time horizon is subdivided into different time intervals in which different possible decision paths can be followed. The proposed approach is applied to a case study and the results are presented according to a decision tree. Lastly, some comparisons and results are used to demonstrate the quality of the results of this approach.


2017 ◽  
Vol 6 (2) ◽  
pp. 98
Author(s):  
Ryland Cairns ◽  
Michael Macpherson

The purpose of this paper is to explore the potential of a six sigma approach to reducing water losses through a combination of water efficiency and leak detection on a private distribution system. The paper takes the form of a case study that investigates the implementation of water reduction strategy across an estate with 26 miles of potable water pipe and over 200 facilities. This incorporates methods developed in the water industry such as water loss reduction and water demand management. The paper demonstrates that large water savings could be made through adoption of a six sigma approach. The approach has the potential to be applied to a wide range of situations including sites with limited technology. This case study provides a useful source for Facilities Managers involved in the management of utilities to determine suitable water saving approaches and strategies for large estates with private water distribution networks.


2003 ◽  
Vol 47 (5) ◽  
pp. 91-97 ◽  
Author(s):  
R. Boe-Hansen ◽  
A.C. Martiny ◽  
E. Arvin ◽  
H.-J. Albrechtsen

In this study, the construction a model distribution system suitable for studies of attached and suspended microbial activity in drinking water under controlled circumstances is outlined. The model system consisted of two loops connected in series with a total of 140 biofilm sampling points. The biofilm from the system was studied using 11 different microbial methods and the results were compared and discussed. The methods were used for biomass quantification (AODC, HPC and ATP determination), visualisation of structure (CLSM), activity measurement (leucine incorporation, AOC removal rate, respiration of benzoic acid, CTC and live/dead stains), and microbial diversity profiling (clone libraries and DGGE).


2019 ◽  
Vol 19 (8) ◽  
pp. 2231-2239 ◽  
Author(s):  
QianSheng Fang ◽  
JiXin Zhang ◽  
ChenLei Xie ◽  
YaLong Yang

Abstract Currently, a total of 3.6 billion people live in water-deficient areas, and the population living in water-deficient areas may reach from 4.8 to 5.7 billion by 2050. Despite that, the water distribution system (WDS) loses an average of 35% of its water resources, and the leakage rates may reach even higher values in some regions. The dual pressures of the lack of water resources and severe WDS leakage become even more problematic considering that commonly used leakage detection methods are time-consuming, labour-intensive, and can only detect single-point leakages. For multiple leakage point detection, these methods often perform poorly. To solve the problem of multiple leakage point detection, this paper presents a method for multiple leakage point detection based on a convolutional neural network (CNN). A CNN can forecast the leakages from a macro-perspective. It extracts the features of the collected historical leakage data by constructing a CNN model and predicts whether the real-time data are leakage data or not based on the learning of the features that are extracted from the historical data. The experimental results show that the detection accuracies based on 21 sensors of one, two, and three leakage points are 99.63%, 98.58% and 95.25%, respectively. After the number of sensors is reduced to eight, the leakage detection accuracies of one, two, and three leakage points are 96.43%, 94.88% and 91.56%, respectively.