Integrated constructed wetland systems: design, operation, and performance of low-cost decentralized wastewater treatment systems

2007 ◽  
Vol 55 (7) ◽  
pp. 155-161 ◽  
Author(s):  
L.L. Behrends ◽  
E. Bailey ◽  
P. Jansen ◽  
L. Houke ◽  
S. Smith

Several different types of constructed wetland systems are being used as decentralized treatment systems including surface-flow, subsurface-flow, vertical-flow, and hybrid systems. Archetypical wetland systems have design strengths and weaknesses, and therefore it should be possible to design combined (integrated) systems to optimize a number of important treatment processes. This study provides comparative efficacy data for two integrated wetland treatment systems (IWTS) designed to enhance treatment of medium strength wastewater generated from a pilot-scale intensive fish farm. Results from the twenty eight months study included consistently high removal of COD (84%+) and ammonia nitrogen (93%) in both systems. Initially, phosphorus removal was also high (>90%) in both systems, but removal efficacy declined significantly over time. Nitrate removal was significantly better in the system that provided sequential aerobic and anoxic environments. Short hydraulic retention times coupled with sustained removal of COD and ammonia indicate that the ReCip components could be a least-cost wastewater treatment technology in the decentralized market sector.

2010 ◽  
Vol 5 (4) ◽  
Author(s):  
Viet-Anh Nguyen ◽  
Antoine Morel ◽  
Karin Tonderski

The decentralized wastewater management utilizing existing infrastructure and low-cost natural treatment processes has a large potential in Vietnam. Centralized wastewater collection and treatment systems are often not affordable. Currently the septic tank is the most common on-site wastewater treatment facility in Vietnam. Nevertheless it has a limited treatment performance. The Improved Septic Tank, also known as Baffled Septic Tank with or without Anaerobic Filter (BASTAF or BAST) represents a valuable and promising alternative to the conventional septic tank. Results of laboratory- and pilot-scale research on BAST and BASTAF systems show that at a hydraulic retention time (HRT) of 2 days the 3-chamber BAST followed by Anaerobic Filter significantly increased the removal efficiencies in terms of BOD, COD and TSS in comparison with a conventional septic tank of the same size. Average treatment efficiencies of 80–90% in terms of BOD, COD and TSS can be achieved. Another component of the study showed that post-treatment of BASTAF effluent in a 2-stage vertical flow constructed wetland (CW) planted with locally available macrophytes allowed the achievement of level A, Vietnamese standard for wastewater discharge in terms of COD, BOD5, TSS, TN, NH4-N and T-P. Results of this study are now being implemented in different provinces inVietnam.


2020 ◽  
Vol 7 (2) ◽  
pp. 70-74
Author(s):  
Fidelis C. Nkeshita ◽  
A. A. Adekunle ◽  
R. B. Onaneye ◽  
O. Yusuf

Wastewater from abattoir sources in urban areas can adversely affect the environment and cause health problems. This research investigated the ability of a bamboo constructed wetland system (BCWS) using Bambusa vulgaris, to treat wastewater from abattoir by removing nutrients and organics. This study adopted pilot scale reactors with bed dimension of 1 m length x 1 m width x 1 m depth to simulate a horizontal sub-surface flow constructed wetland and planted with six strands of bamboo plants. Parameters analyzed include the nutrients (in the form of phosphate and nitrate) and the organics (in the form of Chemical oxygen demand, COD and Biochemical oxygen demand, BOD). The effluent analysis that were carried out within a 28-day retention period showed that there was a very good decrease in the nutrient pollutant parameters; phosphate (99.6 %), nitrate (98.5 %). The organics showed a lesser performance with a 39.3 % removal efficiency for COD and 49.9 % removal efficiency for BOD. Bamboo can be used in a BCWS for low cost green technology in urban areas and can be improved upon by increasing the number of bamboo shoot in order to have a larger root system.


2003 ◽  
Vol 48 (5) ◽  
pp. 257-266 ◽  
Author(s):  
K. Boonsong ◽  
S. Piyatiratitivorakul ◽  
P. Patanaponpaiboon

The study evaluated the possibility of using mangrove plantation to treat municipal wastewater. Two types of pilot scale (100 × 150 m2) free water surface constructed wetland were set up. One system was a natural Avicennia marina dominated forest system. The other system was a newly planted system in which seedlings of Rhizophora spp., A. marina, Bruguiera cylindrica and Ceriops tagal were planted in 4 strips. Municipal wastewater was retained within the systems for 7 and 3 days, respectively. The results indicated that the average removal percentage of TSS, BOD, NO3-N, NH4-N, TN, PO4-P and TP in the newly planted system were 27.6-77.1, 43.9-53.9, 37.6-47.5, 81.1-85.9, 44.8-54.4, 24.7-76.8 and 22.6-65.3, respectively. Whereas the removal percentage of those parameters in the natural forest system were 17.1-65.9, 49.5-51.1, 44.0-60.9, 51.1-83.5, 43.4-50.4, 28.7-58.9 and 28.3-48.0, respectively. Generally, the removal percentages within the newly planted system and the natural forest system were not significantly different. However, when the removal percentages were compared with detention time, TSS, PO4-P and TP percentages removed were significantly higher in the 7-day detention time treatment. Even though the removal percentages were highly varied and temporally dependent, the overall results showed that mangrove plantation could be used as constructed wetland for municipal wastewater treatment in a similar way to the natural mangrove system.


2015 ◽  
Vol 16 (1) ◽  
pp. 69-82 ◽  
Author(s):  
Anita Jakubaszek ◽  
Zofia Sadecka

Abstract This paper presents the results of the research work related to the removal efficiency from wastewater organic pollutants and suspended solids at HSSF (horizontal subsurface flow) constructed wetland. The average effectiveness defined as loss of value COD in wastewater has reached 77%, for BOD5 - 80% and TOC - 82%. The effect of seasonal temperature changes and the period of plant vegetation and rest on the effectiveness of wastewater treatment were also analyzed. The results of the presented research showed a decrease in the efficiency of removing organic pollutants from wastewater and suspended solids in the autumn and winter. During the vegetation the object in Małyszyn has been characterized by the effectiveness of wastewater treatment at the level of 78% for COD, 82% for BOD5, and in the non-vegetation period the effectiveness has decreased up to 75% for COD and 74% for BOD5. During the plants growth the total suspension was removed in 88%, whereas during the plants rest efficiency of removing lowered to 69%.


2007 ◽  
Vol 7 (6) ◽  
pp. 815-819 ◽  
Author(s):  
B. Hegazy ◽  
M.A. El-Khateeb . ◽  
A. El-adly Amira . ◽  
M.M. Kamel .

2000 ◽  
Vol 41 (1) ◽  
pp. 57-63 ◽  
Author(s):  
S. Vandaele ◽  
C. Thoeye ◽  
B. Van Eygen ◽  
G. De Gueldre

In Flanders (Belgium) an estimated 15% of the population will never be connected to a central wastewater treatment plant (WWTP). Small WWTPs can be a valuable option. Aquafin bases the decision to build SWWTPs on a drainage area study. To realise an accelerated construction the process choice is made accordingly to a standard matrix, which represents the different technologies in function of the size and the effluent consents. A pilot scale constructed two-stage reed bed is used to optimise the concept of the reed beds. The concept consists of a primary clarifier, two parallel vertical flow reed beds followed by a sub-surface flow reed bed. The removal efficiency of organic pollutants is high (COD: 89%, BOD: 98%). Phosphorus removal is high at the start-up but diminishes throughout the testing period (from 100% to 71% retention after 7 months). Nitrogen removal amounts to 53% on average. Nitrification is complete in summer. Denitrification appears to be the limiting factor. In autumn leakage of nitrogen is assumed. Removal efficiency of pathogens amounts to almost 99%. Clogging forms a substantial constraint of the vertical flow reed bed. Problems appear to be related with presettlement, feed interval and geotextile.


2018 ◽  
Vol 16 (2) ◽  
pp. 155
Author(s):  
Euis Nurul Hidayah ◽  
Andrysah Djalalembah ◽  
Gina Aprilliana Asmar ◽  
Okik Hendriyanto Cahyonugroho

ABSTRAKPenanganan air limbah domestik Kota Surabaya selama ini dilakukan dengan 2 cara, yakni untuk blackwater dialirkan ke tangki septik dan greywater dialirkan ke drainase tanpa pengolahan. Hal ini menyebabkan peningkatan pencemar pada sungai sebagai air baku. Salah satu teknologi alternatif yang dapat diaplikasikan dengan mudah dan rendah biaya operasional dibanding pengolahan air limbah lainnya adalah constructed wetland dengan menggunakan tanaman Iris pseudoacorus sebagai kombinasi pengolahan biofilter dan proses fitoteknologi. Penelitian ini dilakukan untuk mengetahui efisiensi dari constructed wetland dengan tanaman Iris pseudoacorus untuk mengolah limbah domestik, serta menentukan bagaimana pengaruh dari adanya aerasi dan pengaruh waktu tinggal pada sistem constructed wetland dalam menurunkan bahan organik dan nitrogen pada air limbah. Penelitian ini dilakukan dalam skala uji laboratorium menggunakan reaktor berkapasitas 30 liter. Air limbah dialirkan pada reaktor dengan waktu tinggal 2 hari dan 3 hari, dengan variasi aerasi dan efisiensi pencemar diukur dengan parameter BOD, dan ammonia. Hasil penelitian ini menunjukan bahwa kemampuan penyisihan BOD, dan ammonia dari limbah air domestik oleh reaktor constructed wetland dengan tambahan aerasi dan waktu tinggal selama 4 hari sangat efektif. Reaktor ini mampu menurunkan nilai BOD hingga 96% dan nilai ammonia sebesar 97%.ABSTRACTWastewater domestic in Surabaya City has been treated in two methods, including septic tank for blackwater and directly discharged into drainage system for greywater. This caused an increasing pollutant loading in source water. Constructed wetland with Iris pseudoacorus, one of the alternative natural treatment technology through biofilter and phytotechnology process, could be applied easily and less costly to other treatment. This research was conducted to know the efficiency of constructed wetland with Iris pseudoacorus in domestic wastewater treatment, and to reveal the effect of aeration and detention time in reducing organic and nitrogen content in domestic wastewater. Experiment has been conducted on a laboratory scale of continue aerated reactor and without aeration as control reactor. Detention time (days) 2 and 3 was setup, then sample was taken for BOD and ammonia measurement. The results indicated that constructed wetland with aeration and detention time 4 days had a higher performance to remove BOD up to 96% and ammonia up to 97% than without aeration and less than 4 days process.Keywords: Domestic Wastewater, Constructed Wetland, Phytotechnology, Iris pseudoacorus, Aeration.Sitasi: Hidayah, E. N., Djalalembah, A., Asmar, G.A. dan Cahyonugroho, G.A. (2018). Pengaruh aerasi dalam constructed wetland pada pengolahan air limbah domestik. Jurnal Ilmu Lingkungan, 16(2),155-161, doi:10.14710/jil.16.2.155-161


Sign in / Sign up

Export Citation Format

Share Document