scholarly journals Benchmarking of energy consumption in municipal wastewater treatment plants – a survey of over 200 plants in Italy

2018 ◽  
Vol 77 (9) ◽  
pp. 2242-2252 ◽  
Author(s):  
M. Vaccari ◽  
P. Foladori ◽  
S. Nembrini ◽  
F. Vitali

Abstract One of the largest surveys in Europe about energy consumption in Italian wastewater treatment plants (WWTPs) is presented, based on 241 WWTPs and a total population equivalent (PE) of more than 9,000,000 PE. The study contributes towards standardised resilient data and benchmarking and to identify potentials for energy savings. In the energy benchmark, three indicators were used: specific energy consumption expressed per population equivalents (kWh PE−1 year−1), per cubic meter (kWh/m3), and per unit of chemical oxygen demand (COD) removed (kWh/kgCOD). The indicator kWh/m3, even though widely applied, resulted in a biased benchmark, because highly influenced by stormwater and infiltrations. Plants with combined networks (often used in Europe) showed an apparent better energy performance. Conversely, the indicator kWh PE−1 year−1 resulted in a more meaningful definition of a benchmark. High energy efficiency was associated with: (i) large capacity of the plant, (ii) higher COD concentration in wastewater, (iii) separate sewer systems, (iv) capacity utilisation over 80%, and (v) high organic loads, but without overloading. The 25th percentile was proposed as a benchmark for four size classes: 23 kWh PE−1 y−1 for large plants > 100,000 PE; 42 kWh PE−1 y−1 for capacity 10,000 < PE < 100,000, 48 kWh PE−1 y−1 for capacity 2,000 < PE < 10,000 and 76 kWh PE−1 y−1 for small plants < 2,000 PE.

2014 ◽  
Vol 69 (5) ◽  
pp. 1088-1093 ◽  
Author(s):  
H. Itokawa ◽  
K. Tsuji ◽  
K. Yamashita ◽  
T. Hashimoto

In Japan, membrane bioreactor (MBRs) have been installed in 17 small-scale municipal wastewater treatment plants (WWTPs) in the past 8 years, together with two recently installed MBRs for larger-scale WWTPs. In this study, design and operating data were collected from 17 of them as part of a follow-up survey, and aspects including system design, biological treatment, membrane operation, problems and costs were overviewed. Because most of the MBRs were designed according to standardized guidance, system configuration of the plants was similar; pre-denitrification using the Modified Ludzack-Ettinger (MLE) process with membrane units submerged in aerobic tanks, following a fine screen and flow equalization tank. This led to effluent quality with biochemical oxygen demand and T-N of less than 3.5 and 7.4 mg/L, respectively, for nine plants on an annual average basis. It was a common practice in extremely under-loaded plants to operate the membrane systems intermittently. Frequency of recovery cleaning events was plant-specific, mostly ranging from 1 to 5 times/year. Cost evaluation revealed that specific construction costs for the small-scale MBRs were no more than for oxidation ditch plants. Although specific energy consumption values tended to be high in the under-loaded plants, the demonstration MBR, where several energy reducing measures had been incorporated, attained specific energy consumption of 0.39 kWh/m3 under full-capacity operation.


2020 ◽  
Vol 15 (2) ◽  
pp. 515-527
Author(s):  
L. Desa ◽  
P. Kängsepp ◽  
L. Quadri ◽  
G. Bellotti ◽  
K. Sørensen ◽  
...  

Abstract Many wastewater treatment plants (WWTP) in touristic areas struggle to achieve the effluent requirements due to seasonal variations in population. In alpine areas, the climate also determines a low wastewater temperature, which implies long sludge retention time (SRT) needed for the growth of nitrifying biomass in conventional activated sludge (CAS). Moreover, combined sewers generate high flow and dilution. The present study shows how the treatment efficiency of an existing CAS plant with tertiary treatment can be upgraded by adding a compact line in parallel, consisting of a Moving Bed Biofilm Reactor (MBBR)-coagulation-flocculation-disc filtration. This allows the treatment of influent variations in the MBBR and a constant flow supply to the activated sludge. The performance of the new 2-step process was comparable to that of the improved existing one. Regardless significant variations in flow (10,000–25,000 m3/d) and total suspended solids (TSS) (50–300 mg/L after primary treatment) the effluent quality fulfilled the discharge requirements. Based on yearly average effluent data, TSS were 11 mg/L, chemical oxygen demand (COD) 27 mg/L and total phosphorus (TP) 0.8 mg/L. After the upgrade, ammonium nitrogen (NH4-N) dropped from 4.9 mg/L to 1.3 mg/L and the chemical consumption for phosphorus removal was reduced.


2013 ◽  
Vol 20 (1) ◽  
pp. 199-208 ◽  
Author(s):  
Marketa Julinova ◽  
Jan Kupec ◽  
Roman Slavik ◽  
Maria Vaskova

Abstract A synthetic polymer, polyvinylpyrrolidone (PVP - E 1201) primarily finds applications in the pharmaceutical and food industries due to its resistance and zero toxicity to organisms. After ingestion, the substance passes through the organism unchanged. Consequently, it enters the systems of municipal wastewater treatment plants (WWTP) without decomposing biologically during the waste treatment process, nor does it attach (through sorption) to particles of activated sludge to any significant extent, therefore, it passes through the system of a WWTP, which may cause the substance to accumulate in the natural environment. For this reason the paper investigates the potential to initiate aerobic biodegradation of PVP in the presence of activated sludge from a municipal wastewater treatment plant. The following agents were selected as the initiators of the biodegradation process - co-substrates: acrylamide, N-acethylphenylalanine and 1-methyl-2-pyrrolidone, a substance with a similar structure to PVP monomer. The biodegradability of PVP in the presence of co-substrates was evaluated on the basis of biological oxygen demand (BOD) as determined via a MicroOxymax O2/CO2/CH4 respirometer. The total substrate concentration in the suspension equaled 400 mg·dm-3, with the ratio between PVP and the cosubstrate being 1:1, while the concentration of the dry activated sludge was 500 mg·dm-3. Even though there was no occurrence of a significant increase in the biodegradation of PVP alone in the presence of a co-substrate, acrylamide appeared to be the most effective type of co-substrate. Nevertheless, a recorded decrease in the slope of biodegradation curves over time may indicate that a process of primary decomposition was underway, which involves the production of metabolites that inhibit activated sludge microorganisms. The resulting products are not identified at this stage of experimentation.


2020 ◽  
Vol 2 (1) ◽  
pp. 36
Author(s):  
Popi Christoforidou ◽  
George Bariamis ◽  
Maria Iosifidou ◽  
Eri Nikolaidou ◽  
Petros Samaras

Wastewater treatment, as a crucial component of the urban water environment, consists of several energy-consumptive stages, therefore efficiency and energy savings measures are essential to maintain them as environmentally sustainable and economically viable. Operational and technical data from WWTPs in Greece have been collected as well as a sample from 61 facilities with key energy profile components. Energy consumption was assessed by specific key performance indicators (KPIs); specific energy consumption expressed per population equivalent (from 3 to 150 kWh/PE), per cubic meter treated (from 0.2 to 2.0 kWh/m3) and per unit of organic load removed (from 0.03 to 7.13 kWh/CODremoved).


Water ◽  
2019 ◽  
Vol 11 (8) ◽  
pp. 1611 ◽  
Author(s):  
Daniela Fighir (Arsene) ◽  
Carmen Teodosiu ◽  
Silvia Fiore

Municipal wastewater treatment plants (MWWTPs) are essential infrastructures in any urban context, but they may be considered as a potential source of greenhouse gas (GHG) emissions and should be coherent with European Union (EU) policy on energy efficiency. This study presents a sustainability evaluation of four Italian and Romanian MWWTPs in terms of energy efficiency and greenhouse gas emissions using Energy Performance and Carbon Emissions Assessment and Monitoring (ECAM) tool software. The obtained results indicated that biogas recovery improved energy performances, while the largest contributions in terms of GHG emissions were in all cases caused by energy consumption and methane produced during wastewater treatment. The Romanian plants exhibited higher GHG emissions, compared to the Italian plants, mainly because of the different values of national conversion factors for grid electricity (0.41 kg CO2/kWh for Italy and 1.07 kg CO2/kWh for Romania). Two scenarios aimed at enhancing the overall sustainability were hypothesized, based on increasing the serviced population or energy efficiency, achieving significant improvements. A sustainability assessment of MWWTPs should be adopted as a useful tool to help water utilities to introduce low-energy, low-carbon management practices as well as being useful for policy recommendations.


2021 ◽  
Vol 13 (13) ◽  
pp. 7198
Author(s):  
Eleni P. Tsiakiri ◽  
Aikaterini Mpougali ◽  
Ioannis Lemonidis ◽  
Christos A. Tzenos ◽  
Sotirios D. Kalamaras ◽  
...  

Wastewater treatment plants have been traditionally developed for the aerobic degradation of effluent organic matter, and are associated with high energy consumption. The adoption of sustainable development targets favors the utilization of every available energy source, and the current work aims at the identification of biomethane potential from non-conventional sources derived from municipal wastewater treatment processes. Byproducts derived from the primary treatment process stage were collected from four sewage treatment plants in Greece with great variation in design capacity and servicing areas with wide human activities, affecting the quality of the influents and the corresponding primary wastes. The samples were characterized for the determination of their solids and fats content, as well as the concentration of leached organic matter and nutrients, and were subjected to anaerobic digestion treatment for the measurement of their biomethane production potential according to standardized procedures. All samples exhibited potential for biogas utilization, with screenings collected from a treatment plant receiving wastewater from an area with combined rural and agro-industrial activities presenting the highest potential. Nevertheless, these samples had a methanogens doubling time of around 1.3 days, while screenings from a high-capacity unit proved to have a methanogens doubling time of less than 1 day. On the other hand, floatings from grit chambers presented the smallest potential for energy utilization. Nevertheless, these wastes can be utilized for energy production, potentially in secondary sludge co-digestion units, converting a treatment plant from an energy demanding to a zero energy or even a power production process.


2020 ◽  
Vol 81 (9) ◽  
pp. 2011-2022
Author(s):  
Vallo Kõrgmaa ◽  
Mailis Laht ◽  
Riin Rebane ◽  
Erki Lember ◽  
Karin Pachel ◽  
...  

Abstract Chemical pollution poses a threat to the aquatic environment and to human health. Wastewater treatment plants are the last defensive line between the aquatic environment and emissions of pollutants. This study focuses on identification of most relevant hazardous substances in Estonian municipal wastewater and their fate in the treatment process. During this study, seasonal wastewater and sewage sludge samples were collected from nine municipal wastewater treatment plants and analyzed for 282 hazardous substances, including EU (n = 45) and Estonian (n = 31) priority substances. Results of this study show that several substances that are subject to international restrictions (e.g. Stockholm Convention) are still present in untreated sewage. Wastewater treatment systems that had a greater level of complexity (TEC >5) were more successful in removing hazardous substances. Statistical analyses showed that removal efficiency of organic hazardous substances had significant (p-value <0.05) linear correlation with removal efficiencies of chemical oxygen demand (COD) and total suspended solids (TSS), but a monotonic relationship with operators' competency. This study showed that operators' competency had a strong influence on the stability of the wastewater treatment efficiency and removal of organic hazardous substances.


2017 ◽  
Vol 76 (12) ◽  
pp. 3299-3306
Author(s):  
M. Kaless ◽  
L. Palmowski ◽  
J. Pinnekamp

Abstract The energy content of screenings from six municipal wastewater treatment plants (WWTPs) was examined. Hourly samples of separated screenings were taken over 24 hours at three of the plants to illustrate diurnal variations. To recover the chemical energy, which usually leaves the WWTP with the screenings, a screenings wash press was used to transfer organic matter from the solid into the liquid phase. The chemical energy of raw and compacted washed screenings as well as the chemical energy of washing water were determined by measuring the chemical oxygen demand (COD) for the six WWTPs. A mass weighted average of 1.35 gCOD/gdm (dm: dry matter) was found in the raw screenings of three WWTPs. The overall recovered energy from screenings was found to range from 0.27 to 0.62 gCOD/gdm. This washed-out COD found in the washing water could be sent for anaerobic digestion or to the wastewater treatment process as a carbon source for denitrification.


2010 ◽  
Vol 62 (5) ◽  
pp. 995-1002 ◽  
Author(s):  
J. W. Wang ◽  
T. Z. Zhang ◽  
J. N. Chen

Total emission load reduction of COD, NH4-N, TN, and TP is the key measure in controlling water pollution and eutrophication. Municipal wastewater treatment plants (MWWTPs) are major contributors in lowering energy consumption and reducing pollutant discharge. The flow-based operating costs have not been directly established to relate to costs of pollutant reduction based on an investigation of 11 MWWTPs in China. However, energy consumption to eliminate one kilogram of COD or NH4-N was observed to decrease when the total reduced pollutants is increased. Additional energy consumption required to remove nitrogen and phosphorus is allotted for mixers and internal return pumps. Major factors for operating costs include influent and effluent concentration, design capacity, and flow loading rate. Therefore, an operating cost model for the total emission load reduction of COD, NH4-N, TN, and TP was developed based on energy consumption and the above mentioned major factors. Using this model to calculate the operating costs for MWWTPs would facilitate more reduction of key pollutants than the flow-based method.