The Influence of the Operating Surface Temperature of the Solar Module Equipped with a Holographic Concentrator on Its Performance

Vestnik MEI ◽  
2019 ◽  
Vol 4 (4) ◽  
pp. 50-59
Author(s):  
Bekhruzi T. Shokhzoda ◽  
◽  
Mikhail G. Tyagunov ◽  
2018 ◽  
Vol 73 ◽  
pp. 01008
Author(s):  
Isworo Pujotomo ◽  
Retno Aita Diantari

To meet the needs of electrical energy, there are alternative energy sources such as solar power in a form of solar power plant. An important equipment aim to handle the of converting of solar energy into electrical energy are solar cells. The development of devices used to modify solar energy into electrical energy has been done since the mid-first half of the last century. Gradually the device is named by scientists with a photovoltaic device, or so-called solar cells (solar cell. This research tested polycrystalline solar module in sunny weather, bright cloudy and overcast. The test results show the effect of solar cell surface temperature to the value of its output power [1]. The condition of the polycrystalline solar panels will work optimally at the measured 32° C - 50° C temperature range on the surface of the solar cell.


2019 ◽  
pp. 9-13
Author(s):  
V.Ya. Mendeleyev ◽  
V.A. Petrov ◽  
A.V. Yashin ◽  
A.I. Vangonen ◽  
O.K. Taganov

Determining the surface temperature of materials with unknown emissivity is studied. A method for determining the surface temperature using a standard sample of average spectral normal emissivity in the wavelength range of 1,65–1,80 μm and an industrially produced Metis M322 pyrometer operating in the same wavelength range. The surface temperature of studied samples of the composite material and platinum was determined experimentally from the temperature of a standard sample located on the studied surfaces. The relative error in determining the surface temperature of the studied materials, introduced by the proposed method, was calculated taking into account the temperatures of the platinum and the composite material, determined from the temperature of the standard sample located on the studied surfaces, and from the temperature of the studied surfaces in the absence of the standard sample. The relative errors thus obtained did not exceed 1,7 % for the composite material and 0,5% for the platinum at surface temperatures of about 973 K. It was also found that: the inaccuracy of a priori data on the emissivity of the standard sample in the range (–0,01; 0,01) relative to the average emissivity increases the relative error in determining the temperature of the composite material by 0,68 %, and the installation of a standard sample on the studied materials leads to temperature changes on the periphery of the surface not exceeding 0,47 % for composite material and 0,05 % for platinum.


2019 ◽  
Vol 1 (02) ◽  
pp. 64-67
Author(s):  
Meilisha Putri Pertiwi ◽  
Suci Siti Lathifah

Research on the condition of the nesting habitat of Chelonia mydas (green turtle) in Pangumbahan Beach, Ujung Genteng, South Sukabumi has been carried out. Data retrieval is done 6 times for 2 days, 27-28 November 2017 at 3 observation stations. The abiotic parameters measured include surface temperature and depth of 50 cm, surface humidity and depth of 50 cm, beach width, beach slope, and the size of sand grains. While the biotic parameters measured were density, relative density, the frequency of attendance, and distribution patterns of Pandanus tectorius (sea pandanus) vegetation. Based on the results of data processing, the biophysical conditions in Pangumbahan Beach are still suitable for the Chelonia mydas nesting habitat. It also got clear evidence of the many Chelonia mydas landings during the data collection.


Sign in / Sign up

Export Citation Format

Share Document