Reaction Force and EMG Analyses of Wheelchair Transfers

1994 ◽  
Vol 79 (2) ◽  
pp. 763-766 ◽  
Author(s):  
Y. Tai Wang ◽  
Chang K. Kim ◽  
H. T. Ford ◽  
H. T. Ford

To examine how reaction forces and muscle activity change when transferring from a wheelchair to three different heights, six male able-bodied college students were tested. Analysis indicated that transferring to a lower seat position generated a greater vertical reaction force and required more muscle effort from triceps and posterior deltoid muscles. Transferring to a higher seat position resulted in a shift of the friction force from the anterior-posterior to the medial-lateral direction, and more biceps muscle effort was needed to perform the up-rightward movement. Transferring to a seat at the same height required less muscle effort from the upper extremities.

2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Bartłomiej Zagrodny ◽  
Michał Ludwicki ◽  
Wiktoria Wojnicz

Asymmetrical external loading acting on the musculoskeletal system is generally considered unhealthy. Despite this knowledge, carrying loads in an asymmetrical manner like carrying on one shoulder, with one hand, or on the strap across the torso is a common practice. This study is aimed at presenting the effects of the mentioned load carrying methods on muscle activity assessed by using thermal field and ground reaction forces. Infrared thermography and pedobarographic force platform (ground reaction force/pressure measurement) were used in this study. Experimental results point out an increased load-dependent asymmetry of temperature distribution on the chosen areas of torso and the influence of external loading on ground reaction forces. Results point out that wearing an asymmetrical load should be avoided and are showing which type of carrying the external load is potentially less and the most harmful.


2011 ◽  
Vol 27 (1) ◽  
pp. 22-31 ◽  
Author(s):  
Marco Hagen ◽  
Ewald M. Hennig ◽  
Peter Stieldorf

Nordic walking (NW) was compared with walking (W) and running (R) with respect to upper and lower limb injury risks. 24 NW-instructors performed W, NW, and R trials on a runway covered with artificial turf at controlled speeds. Foot pronation and ground reaction forces were measured as well as shock wave transmission to the right wrist. Comparison of NW and W shows similar results for all of the four chosen velocities (5 km/h, 7 km/h, 8 km/h, 8.5 km/h). Except for the 2nd peak of the vertical ground reaction force, NW results in higher loading rates and horizontal forces as well as higher pronation and pronation velocity values as compared with W. Wrist acceleration values up to 7.6 times gravitational acceleration were recorded in NW. Compared with R at the same speeds (8 km/h and 8.5 km/h), NW can be recommended as low impact sport with 36% lower loading rates and 59% lower pronation velocities. However, the high wrist accelerations in NW reveal that the upper extremities are exposed to considerable repetitive shocks, which may cause overuse injuries of the upper extremities. Thus, additional preventive exercises for the upper limb muscles are recommended as well as using shock absorbing walking poles.


2014 ◽  
Vol 40 (1) ◽  
pp. 49-55 ◽  
Author(s):  
Elissavet Rousanoglou ◽  
Konstantinos Noutsos ◽  
Ioannis Bayios ◽  
Konstantinos Boudolos

Abstract The purpose of this study was to examine the differences in the ground reaction force (GRF) patterns between elite and novice players during two types of handball shots, as well as the relationships between throwing performance and the GRF variables. Ball velocity and throwing accuracy were measured during jump shots and 3-step shots performed by 15 elite and 15 novice players. The GRF pattern was recorded for the vertical and the anterior-posterior GRF components (Kistler forceplate type-9281, 750Hz). One-way ANOVA was used for the group differences and the Pearson coefficient for the correlation between throwing performance and GRF variables (SPSS 21.0, p ≤ 0.05). The elite players performed better in both types of shot. Both groups developed consistent and similar GRF patterns, except for the novices’ inconsistent Fz pattern in the 3-step shot. The GRF variables differed significantly between groups in the 3-step shot (p ≤ 0.05). Significant correlations were found only for ball velocity and predominantly for the novice players during the 3-step shot (p ≤ 0.05). The results possibly highlight a shortage in the novice ability to effectively reduce their forward momentum so as to provide a stable base of support for the momentum transfer up the kinetic chain, a situation that may predispose athletes to injury.


Life ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 630
Author(s):  
Kosuke Oku ◽  
Daisuke Kimura ◽  
Tomotaka Ito ◽  
Akiyoshi Matsugi ◽  
Tatsuya Sugioka ◽  
...  

Repeated high-impact ground forces can lead to injury and decreased performance. While increasing flexor hallucis longus (FHL) muscle activity is known to increase stiffness and elasticity, it is unknown if this also decreases ground reaction forces by shock absorption during landing. This study aimed to determine whether increasing FHL muscle activity affects ground reaction force during landing in healthy subjects. Eight subjects performed single-leg steps onto a force platform for five trials, with and without flexion of the metatarsophalangeal (MTP) joint at the moment of landing. Integrated surface electromyography (sEMG) of the FHL and medial gastrocnemius (MG) and ground reaction forces (GRFs) were measured. sEMG and GRF during the 50 ms before and 100 ms following initial ground contact were analyzed and compared. Flexion of the MTP joint condition significantly decreased the vertical and mediolateral force peaks of GRF, and FHL muscle activity increased. Flexion of the MTP joint at the moment of landing reduces GRF in healthy subjects through force dissipation in the foot, by increased FHL muscle activity. The results suggest that this may contribute to injury prevention by reducing the impact force through flexing the MTP joint at the moment of landing.


2019 ◽  
Vol 126 (5) ◽  
pp. 1315-1325 ◽  
Author(s):  
Andrew B. Udofa ◽  
Kenneth P. Clark ◽  
Laurence J. Ryan ◽  
Peter G. Weyand

Although running shoes alter foot-ground reaction forces, particularly during impact, how they do so is incompletely understood. Here, we hypothesized that footwear effects on running ground reaction force-time patterns can be accurately predicted from the motion of two components of the body’s mass (mb): the contacting lower-limb (m1 = 0.08mb) and the remainder (m2 = 0.92mb). Simultaneous motion and vertical ground reaction force-time data were acquired at 1,000 Hz from eight uninstructed subjects running on a force-instrumented treadmill at 4.0 and 7.0 m/s under four footwear conditions: barefoot, minimal sole, thin sole, and thick sole. Vertical ground reaction force-time patterns were generated from the two-mass model using body mass and footfall-specific measures of contact time, aerial time, and lower-limb impact deceleration. Model force-time patterns generated using the empirical inputs acquired for each footfall matched the measured patterns closely across the four footwear conditions at both protocol speeds ( r2 = 0.96 ± 0.004; root mean squared error  = 0.17 ± 0.01 body-weight units; n = 275 total footfalls). Foot landing angles (θF) were inversely related to footwear thickness; more positive or plantar-flexed landing angles coincided with longer-impact durations and force-time patterns lacking distinct rising-edge force peaks. Our results support three conclusions: 1) running ground reaction force-time patterns across footwear conditions can be accurately predicted using our two-mass, two-impulse model, 2) impact forces, regardless of foot strike mechanics, can be accurately quantified from lower-limb motion and a fixed anatomical mass (0.08mb), and 3) runners maintain similar loading rates (ΔFvertical/Δtime) across footwear conditions by altering foot strike angle to regulate the duration of impact. NEW & NOTEWORTHY Here, we validate a two-mass, two-impulse model of running vertical ground reaction forces across four footwear thickness conditions (barefoot, minimal, thin, thick). Our model allows the impact portion of the impulse to be extracted from measured total ground reaction force-time patterns using motion data from the ankle. The gait adjustments observed across footwear conditions revealed that runners maintained similar loading rates across footwear conditions by altering foot strike angles to regulate the duration of impact.


Sensors ◽  
2019 ◽  
Vol 19 (9) ◽  
pp. 2011 ◽  
Author(s):  
Bessone ◽  
Petrat ◽  
Schwirtz

In the past, technological issues limited research focused on ski jump landing. Today, thanks to the development of wearable sensors, it is possible to analyze the biomechanics of athletes without interfering with their movements. The aims of this study were twofold. Firstly, the quantification of the kinetic magnitude during landing is performed using wireless force insoles while 22 athletes jumped during summer training on the hill. In the second part, the insoles were combined with inertial motion units (IMUs) to determine the possible correlation between kinematics and kinetics during landing. The maximal normal ground reaction force (GRFmax) ranged between 1.1 and 5.3 body weight per foot independently when landing using the telemark or parallel leg technique. The GRFmax and impulse were correlated with flying time (p < 0.001). The hip flexions/extensions and the knee and hip rotations of the telemark front leg correlated with GRFmax (r = 0.689, p = 0.040; r = −0.670, p = 0.048; r = 0.820, p = 0.007; respectively). The force insoles and their combination with IMUs resulted in promising setups to analyze landing biomechanics and to provide in-field feedback to the athletes, being quick to place and light, without limiting movement.


2020 ◽  
pp. 1-12
Author(s):  
Hiroyuki Sakata ◽  
Satoru Hashizume ◽  
Ryo Amma ◽  
Genki Hisano ◽  
Hiroto Murata ◽  
...  

Author(s):  
Kermit G. Davis

In industry, workers perform tasks requiring both lifting and lowering. During concentric lifting, the muscles are shortening as the force is being generated. Conversely, the muscle lengthens while generating force during eccentric lowering. While research on various lifting tasks is extensive, there has been limited research performed to evaluate the lowering tasks. Most of the research that does exist on lowering has investigated muscle activity and trunk strength. None of these studies have investigated spinal loading. The current study estimated the effects of lifting and lowering on spinal loads and predicted moments imposed on the spine. Ten subjects performed both eccentric and concentric lifts under sagittally symmetric conditions. The tasks were performed under isokinetic trunk velocities of 5, 10, 20, 40, and 80 deg/s while holding a box with weights of 9.1, 18.2, and 27.3 kg. Spinal loads and predicted moments in three dimensional space were estimated by an EMG-assisted model which has been adjusted to incorporate the artifacts of eccentric lifting. Eccentric strength was found to be 56 percent greater than during concentric lifting. The lowering tasks produced significantly higher compression forces but lower anterior-posterior shear forces than the concentric lifting tasks. The differences in the spinal loads between the two lifting tasks were attributed to the internal muscle forces and unequal moments resulting from differences in the lifting path of the box. Thus, the differences between the lifting tasks resulted from different lifting styles associated with eccentric and concentric movements


2014 ◽  
Vol 27 (04) ◽  
pp. 257-262 ◽  
Author(s):  
J. Y. W. Kim ◽  
T. C. Garcia-Nolan ◽  
S. Y. Kim ◽  
K. Hayashi ◽  
P. L. Hitchens ◽  
...  

SummaryObjectives: To develop a platform that used standard size force plates for large breed dogs to capture ground reaction force data from any size dog.Methods: A walkway platform was constructed to accommodate two force plates (60 cm x 40 cm) positioned in series to a variety of smaller sizes. It was constructed from a custom wood frame with thick aluminium sheet force plate covers that prevented transfer of load to the force plate, except for rectangular windows of three different dimensions. A friction study was performed to ensure plates did not translate relative to one another during gait trials. A prospective, observational, single crossover study design was used to compare the effect of force platform configuration (full plate size [original plate], half plate size [modified plate]) on ground reaction forces using eight adult healthy Labrador Retriever dogs.Results: Slippage of the steel plate on the force plate did not occur. Peak propulsion force was the only kinetic variable statistically different between the full size and half sized platforms. There were no clinically significant differences between the full and half force platforms for the variables and dogs studied.Discussion and conclusion: The modified force platform allows the original 60 x 40 cm force plate to be adjusted effectively to a 30 x 40 cm, 20 x 40 cm and 15 x 40 cm sized plate with no clinically significant change in kinetic variables. This modification that worked for large breed dogs will potentially allow kinetic analysis of a large variety of dogs with different stride lengths.


Author(s):  
Yoshiaki Sakamoto ◽  
Hisao Izuchi ◽  
Naoko Suzuki

Reaction force of safety valves acting to the piping system is one of key factors for the piping system design around the safety valves. In case of open discharge system, it is well known that a large reaction force acts to the piping corresponding to the fluid momentum force at the atmospheric discharge. On the other hand, reaction forces for closed discharge system may be relatively small since the forces acting to the adjacent two points with flow direction change such as elbows and tees are balanced within very short period. However, large reaction forces may act as a result of unsteady flow just after the initial activation of the safety valve. API RP520 mentioned that a complex time history analysis of the piping system around the safety valves may be required to obtain the transient forces. This paper explains a method of a comprehensive dynamic simulation of piping system around safety valves taking interaction among the valve disc motion, the fluid transient for compressible flow and the piping structural dynamics into account. The simulation results have good agreement with the experimental data. The effectiveness of this method is confirmed throughout an application to actual piping system around safety valves.


Sign in / Sign up

Export Citation Format

Share Document