Abstract The spectrum of random functions of level density as well as radiative strength functions of dipole E1- and M1-transitions of 28Al were determined. Obtained functions can reproduce very precisely the intensity of the two-step cascade following the radiative capture of thermal neutrons for a given energy of the primary transitions. The density of the observed intermediate levels can be reproduced correctly using the mean value of these functions. In this work we proposed a new hypothesis about the dependence of radiative strength functions for gamma-transitions in heated nucleus on the energy of excited levels. The results provide a solid basis that this new hypothesis allows to get realistic estimation on the parameters of nuclear structure in any nucleus, including the light ones.

2015 ◽  
Vol 24 (03) ◽  
pp. 1550018
Author(s):  
Bora Canbula ◽  
Sibel Erşan ◽  
Halil Babacan

γ-ray strength function is the key input for the photonuclear reactions, which have a special astrophysical importance, and should be renormalized by using the nuclear level density for calculating the theoretical average radiative capture width, but performing such renormalization is challenging for light nuclei. With this motivation, recently introduced level density parameter formula including collective effects is used to calculate the average radiative capture width of light nuclei, and therefore to renormalize their γ-ray strength functions. Obtained normalization factors are tested in (n, γ) reactions for the necessity of renormalization for light nuclei.


2009 ◽  
Vol 18 (04) ◽  
pp. 996-1001 ◽  
Author(s):  
V. A. PLUJKO ◽  
O. M. GORBACHENKO ◽  
E. V. KULICH

Photoabsorption cross sections and dipole γ-decay strength functions are calculated and compared with experimental data to test Lorentzian-like models of their description in the middle-weight and heavy atomic nuclei. Approaches with asymmetric shape of the radiative strength function are recommended for overall estimation of the dipole γ-strengths. The ready-to-use table of giant dipole resonance parameters and their errors are obtained from fitting the theoretical calculations for photoabsorption cross sections to the experimental data. Systematics for giant dipole resonance parameters are given.


2019 ◽  
Vol 34 (26) ◽  
pp. 1950210 ◽  
Author(s):  
İsmail Hakki Sarpün ◽  
Hasan Özdoğan ◽  
Kemal Taşdöven ◽  
Hüseyin Ali Yalim ◽  
Abdullah Kaplan

In this study, the level density parameter and the gamma ray strength function effects on photoneutron reaction cross-section calculations for Osmium isotopes were investigated by employing available level density models and gamma ray strength functions within Talys v1.8 and Empire v3.1 nuclear codes. A relative variance analysis was done to determine the best gamma ray strength function. Then, the effect of level density models for the photoneutron reactions was investigated by using the best gamma ray strength function. The results were compared with each other and also with the experimental data taken from the literature.


Author(s):  
Noriyuki Kuwano ◽  
Masaru Itakura ◽  
Kensuke Oki

Pd-Ce alloys exhibit various anomalies in physical properties due to mixed valences of Ce, and the anomalies are thought to be strongly related with the crystal structures. Since Pd and Ce are both heavy elements, relative magnitudes of (fcc-fpd) are so small compared with <f> that superlattice reflections, even if any, sometimes cannot be detected in conventional x-ray powder patterns, where fee and fpd are atomic scattering factors of Ce and Pd, and <f> the mean value in the crystal. However, superlattices in Pd-Ce alloys can be analyzed by electron microscopy, thanks to the high detectability of electron diffraction. In this work, we investigated modulated superstructures in alloys with 12.5 and 15.0 at.%Ce.Ingots of Pd-Ce alloys were prepared in an arc furnace under atmosphere of ultra high purity argon. The disc specimens cut out from the ingots were heat-treated in vacuum and electrothinned to electron transparency by a jet method.


1987 ◽  
Vol 26 (06) ◽  
pp. 253-257
Author(s):  
M. Mäntylä ◽  
J. Perkkiö ◽  
J. Heikkonen

The relative partition coefficients of krypton and xenon, and the regional blood flow in 27 superficial malignant tumour nodules in 22 patients with diagnosed tumours were measured using the 85mKr- and 133Xe-clearance method. In order to minimize the effect of biological variables on the measurements the radionuclides were injected simultaneously into the tumour. The distribution of the radiotracers was assumed to be in equilibrium at the beginning of the experiment. The blood perfusion was calculated by fitting a two-exponential function to the measuring points. The mean value of the perfusion rate calculated from the xenon results was 13 ± 10 ml/(100 g-min) [range 3 to 38 ml/(100 g-min)] and from the krypton results 19 ± 11 ml/(100 g-min) [range 5 to 45 ml/(100 g-min)]. These values were obtained, if the partition coefficients are equal to one. The equations obtained by using compartmental analysis were used for the calculation of the relative partition coefficient of krypton and xenon. The partition coefficient of krypton was found to be slightly smaller than that of xenon, which may be due to its smaller molecular weight.


1968 ◽  
Vol 20 (01/02) ◽  
pp. 044-049 ◽  
Author(s):  
B Lipiński ◽  
K Worowski

SummaryIn the present paper described is a simple test for detecting soluble fibrin monomer complexes (SFMC) in blood. The test consists in mixing 1% protamine sulphate with diluted oxalated plasma or serum and reading the optical density at 6190 Å. In experiments with dog plasma, enriched with soluble fibrin complexes, it was shown that OD read in PS test is proportional to the amount of fibrin recovered from the precipitate. It was found that SFMC level in plasma increases in rabbits infused intravenously with thrombin and decreases after injection of plasmin with streptokinase. In both cases PS precipitable protein in serum is elevated indicating enhanced fibrinolysis. In healthy human subjects the mean value of OD readings in plasma and sera were found to be 0.30 and 0.11, while in patients with coronary thrombosis they are 0.64 and 0.05 respectively. The origin of SFMC in circulation under physiological and pathological conditions is discussed.


1996 ◽  
Vol 75 (05) ◽  
pp. 772-777 ◽  
Author(s):  
Sybille Albrecht ◽  
Matthias Kotzsch ◽  
Gabriele Siegert ◽  
Thomas Luther ◽  
Heinz Großmann ◽  
...  

SummaryThe plasma tissue factor (TF) concentration was correlated to factor VII concentration (FVIIag) and factor VII activity (FVIIc) in 498 healthy volunteers ranging in age from 17 to 64 years. Immunoassays using monoclonal antibodies (mAbs) were developed for the determination of TF and FVIIag in plasma. The mAbs and the test systems were characterized. The mean value of the TF concentration was 172 ± 135 pg/ml. TF showed no age- and gender-related differences. For the total population, FVIIc, determined by a clotting test, was 110 ± 15% and the factor VIlag was 0.77 ± 0.19 μg/ml. FVII activity was significantly increased with age, whereas the concentration demonstrated no correlation to age in this population. FVII concentration is highly correlated with the activity as measured by clotting assay using rabbit thromboplastin. The ratio between FVIIc and FVIIag was not age-dependent, but demonstrated a significant difference between men and women. Between TF and FVII we could not detect a correlation.


1966 ◽  
Vol 16 (01/02) ◽  
pp. 038-050 ◽  
Author(s):  
Ulla Hedner ◽  
Inga Marie Nilsson ◽  
B Robertson

SummaryThe plasminogen content was determined by a casein method in plasma and serum from 20 normal volunteers. The mean plasminogen content was found to be 10.1 ACU (the arbitrary caseinolytic unit defined in such a way that using a 3% casein solution and a digestion time of 20 min. at 37°C, 10 ACU gave an extinction of 0.300). No difference between serum and plasma regarding the plasminogen content was found.Plasminogen was determined in drained and drained plus washed clots prepared from 2 ml plasma. The highest values found in the drained clots were 0.9 ACU/clot and 0.2 ACU/clot in the drained plus washed clots.Plasminogen was also determined in drained and drained plus washed clots prepared from plasma with added purified plasminogen. The plasminogen was recovered in the washing fluid. According to these tests, then, purified added plasminogen is washed out of the clots.The plasminogen content of 20 thrombi obtained post mortem was also determined. The mean value was found to be 0.7 ACU/cm thrombus. Judging from our results, the “intrinsic clot lysis theory” is not the main mechanism of clot dissolution.