scholarly journals Significance of Fast in Blunt Abdominal Trauma

2020 ◽  
Vol 19 (2) ◽  
pp. 140-146
Author(s):  
Amir Hinbis Masawod ◽  
◽  
Hazim Jabbar Kashtal ◽  
Ahmed Modher Khalaf

Background: Blunt abdominal trauma is a common problem in our country.Some of the cases had been explored on no bases which were negative by FAST(focused assessment with sonography of trauma)FAST is a tool to detect intra-abdominal collection. Objective: To appreciate the value of (FAST) in blunt abdominal trauma. Patients and Methods: This study performed by a collection of 100 cases of blunt abdominal trauma admitted to the emergency department at Baquba Teaching Hospital from the period 1st January, 2013 to 31st December 2013 fast performed on all cases to detect any intra-abdominal collection, then correlation with this result and laparotomy or conservative results. Results: Out of 100 patients, Twenty seven cases had intra-abdominal collection and seventy three cases had no intra-abdominal collection by fast, 27 cases were positive and one case false positive and 73 cases were negative and 2 false-negative results and 71 true negative. The sensitivity was 92.8 % and specificity 98.6%. The positive predictive value was 96.2 % and negative predictive value 97.2 % and the accuracy 97 %. Conclusion: Focused assessment sonography of trauma can detect intra-abdominal fluid accurately and rapidly, FAST potentially valuable tool for better assessment of trauma in the emergency department. Keywords: Focus assessment with sonography of trauma (FAST), blunt abdominal trauma, abdominal emergency

2013 ◽  
Vol 57 (9) ◽  
pp. 4578-4580 ◽  
Author(s):  
Nathalie Tijet ◽  
David Boyd ◽  
Samir N. Patel ◽  
Michael R. Mulvey ◽  
Roberto G. Melano

ABSTRACTThe Carba NP test was evaluated against a panel of 244 carbapenemase- and non-carbapenemase-producingEnterobacteriaceaeandPseudomonas aeruginosaisolates. We confirmed the 100% specificity and positive predictive value of the test, but the sensitivity and negative predictive value were 72.5% and 69.2%, respectively, and increased to 80% and 77.3%, respectively, using a more concentrated bacterial extract. False-negative results were associated with mucoid strains or linked to enzymes with low carbapenemase activity, particularly OXA-48-like, which has emerged globally in enterobacteria.


2019 ◽  
Vol 57 (02) ◽  
pp. 133-138
Author(s):  
Eva-Marie Warnken ◽  
Michael Uder ◽  
Hubert Stein ◽  
Michael Wucherer ◽  
Michael Lell ◽  
...  

Abstract Purpose The goal of this study was to evaluate the experience of 11 years of wire-guided forceps biopsy via PTCD in patients with obstructive jaundice. Materials and methods In a retrospective approach, 56 biopsies in 51 patients were analyzed (22 female, 29 male). Data was collected from 2006 to 2016. Mean age was 71 years (range: 34 – 86 years). Data was extracted from dig. Patients’ records (KIS, PACS, RIS) to be analyzed in Microsoft Excel. Results All 56 procedures were technically successful. Stenosis in anastomoses were benign due to scarring in 7 patients and in 9 due to papillitis or others. In 4 patients, results in anastomosis were malignant. In 19 patients without anastomosis, CCC was the diagnosis, thereof 10 klatskin, 9 stenosis in other locations, followed by gastric, pancreatic, and colon carcinoma in 5, 3, and 2 patients. Three patients had a CUP (multimetering in case of more than 1 related category). Overall results were 35 mal. and 16 benign, 76.8 % of all proc. had a correct histopathologic result, and 23.2 % were false negative. Sensitivity was 65.8 %, which results in negative predictive value of 58.1 %. There was no false positive and so specificity was 100 %, as was the positive predictive value. False negative results (no malignancy but clinically and imaging suspect) were corrected by rerunning the procedure, by CT-guided biopsy or by 1 PET-CT. In 1 case the surg. sample brought the result. Minor complications occurred in 8 patients: shivering in 1 case, distinct but hemodynamically not relevant hemobilia in 5 cases, 2 portovenal bleedings. All bleedings were short-term and self-limiting. Conclusion Despite good feasibility, low peri- and post-interv. risk and high validity the forceps biopsy via PTCD is not widely used. For experienced interventionalists, it is an effective method for obtaining histology.


2017 ◽  
Vol 68 (3) ◽  
pp. 276-285 ◽  
Author(s):  
Francesco Cinquantini ◽  
Gregorio Tugnoli ◽  
Alice Piccinini ◽  
Carlo Coniglio ◽  
Sergio Mannone ◽  
...  

Background and Aims Laparotomy can detect bowel and mesenteric injuries in 1.2%–5% of patients following blunt abdominal trauma. Delayed diagnosis in such cases is strongly related to increased risk of ongoing sepsis, with subsequent higher morbidity and mortality. Computed tomography (CT) scanning is the gold standard in the evaluation of blunt abdominal trauma, being accurate in the diagnosis of bowel and mesenteric injuries in case of hemodynamically stable trauma patients. Aims of the present study are to 1) review the correlation between CT signs and intraoperative findings in case of bowel and mesenteric injuries following blunt abdominal trauma, analysing the correlation between radiological features and intraoperative findings from our experience on 25 trauma patients with small bowel and mesenteric injuries (SBMI); 2) identify the diagnostic specificity of those signs found at CT with practical considerations on the following clinical management; and 3) distinguish the bowel and mesenteric injuries requiring immediate surgical intervention from those amenable to initial nonoperative management. Materials and Methods Between January 1, 2008, and May 31, 2010, 163 patients required laparotomy following blunt abdominal trauma. Among them, 25 patients presented bowel or mesenteric injuries. Data were analysed retrospectively, correlating operative surgical reports with the preoperative CT findings. Results We are presenting a pictorial review of significant and frequent findings of bowel and mesenteric lesions at CT scan, confirmed intraoperatively at laparotomy. Moreover, the predictive value of CT scan for SBMI is assessed. Conclusions Multidetector CT scan is the gold standard in the assessment of intra-abdominal blunt abdominal trauma for not only parenchymal organs injuries but also detecting SBMI; in the presence of specific signs it provides an accurate assessment of hollow viscus injuries, helping the trauma surgeons to choose the correct initial clinical management.


2018 ◽  
Vol 10 (3) ◽  
pp. 217-21
Author(s):  
Emy Noerwidayati ◽  
Andaru Dahesihdewi ◽  
Osman Sianipar

BACKGROUND: Klepsiella pneumoniae, one of clinical isolates, is frequently found causative agent of hospital acquired infection. Currently, K. pneumoniae is found as extended-Spectrum β-lactamases (ESBL) producer, allowing it to become multidrugresistant. A clinical laboratory with limited facility needs a valid, reliable, inexpensive and simple laboratory test to control its infection and antimicrobial-resistancy. The aim of this study is to evaluate the diagnostic performance of a ESBL media to detect ESBL-producing K. pneumoniae.METHODS: An independent and blind comparative study of ChromID ESBL media and Double Disc Synergy Test (DDST) was conducted for detecting the clinical isolate of ESBL-producing K. pneumoniae. Clinical isolates of K. pneumoniae collected from the Clinical Laboratory of Dr. Sardjito Hospital were isolated.RESULTS: There were 103 clinical isolates of K. pneumoniae, which were isolated from urine, pus, blood, stool, cerebrospinal fluid, sputum, drain liquid, nasal sinus liquid, gastric wash, bronchi liquid, injury liquid and nasal swab. The number of true positive, true negative, false positive and false negative results were 74, 18, 9 and 2, respectively. Meanwhile, the sensitivity, specificity, positive predictive value, negative predictive value, likelihood ratio for positive result and likelihood ratio for negative result of the new ESBL media were 97.4%, 66.7%, 89.2%, 90%, 2.9 and 0.03, respectively.CONCLUSION: Since the new ESBL media and DDST results were similar, so the new ESBL media could be used for screening patients with clinical presentation that indicating a high suspicious of ESBL-producing bacteria.KEYWORDS: K. pneumoniae, ChromID ESBL, DDST, ESBL, sensitivity


2018 ◽  
Vol 5 (11) ◽  
pp. 3713
Author(s):  
Arshid Iqbal Qadri ◽  
Younis Ahmad ◽  
Gowhar Aziz Bhat ◽  
Aamir A. Khan ◽  
Khalid Bashir

Background: Blunt abdominal trauma is a frequent cause for presentation of children to the Emergency Department. Children are prone to sustain injuries to intra-abdominal organs after blunt abdominal trauma because of their peculiar body habitus and relatively immature musculoskeletal system. Objectives of this study is to assess the various epidemiological parameters that influences the causation of trauma as well as injury pattern in blunt trauma abdomen in pediatric population.Methods: The present observational hospital based prospective study was carried out in 96 blunt abdominal trauma patients of both sexes aged up to 12 years, over a period of 2 years. The parameters such as age group, sex, mode of trauma, type of injury, and the overall mortality as well as mortality were assessed.Results: The most common mode of injury was road traffic accidents (54.2%) followed by fall from height (41.70%). Splenic injury was the most common in 58.30%, followed by hepatic injuries 34.40% and renal injuries 12.50 %. The accuracy of ultrasonography (USG) was 83.33% while accuracy of computed tomography (CECT) as a diagnostic test was 93.33%. When comparing USG findings with operative findings sensitivity of USG was 88% with positive predictive value (PPV) of 91.66% while as specificity was 60% with negative predictive value (NPV) of 50%. Sensitivity of CT scan was 96.00% with PPV of 96.00% and specificity of CECT scan was 80.00% with NPV of 80.00%.Conclusions: The majority of pediatric injuries are preventable by knowing the epidemiology and pattern of pediatric trauma.


2022 ◽  
Author(s):  
Elsayed Ghannam ◽  
Salah Rozaik ◽  
Ramy Hasan Agwa ◽  
Ahmed Marwan ◽  
Mervat El-Sayed Mashaly ◽  
...  

Abstract Background: Liver is the largest endocrine organ in the body. It is a key organ in insulin mediated metabolism, growth hormone and insulin like growth factors (IGF) pathway. Liver cirrhosis is the end result of many chronic diseases including hepatitis C virus infection. Child-Turcotte-Pugh (CTP) score is the standard used in assessment of hepatic reserve but it has its drawbacks in the form of subjective variables, hepatic encephalopathy and ascites. The aim of this work is to assess IGF-1 in patients with liver cirrhosis, correlate it with CTP score and assess value of modified combined CTP-IGF-1 score. Patients and Methods: 170 patients with CLD (liver cirrhosis) and 72 healthy controls in the study groups were enrolled in the study. All patients were subjected to thorough history, clinical examination and laboratory assessment. IGF-1 was measured and all patients were evaluated using CTP and CTP-IGF-1 scores. Results: IGF1 showed highly significant low values in the study group in comparison to controls (42.15 ± 27.976 and 66.31 ± 33.084 ng/ml respectively, p <0.001). It showed also highly significant negative correlation to CTP score in the study group (p < 0.001) with progressive decrements with CTP score stage progression where IGF1 levels were 48.32 ± 28.611, 40.28 ± 25.869 and 18.80 ± 15.953 ng/ml (mean ± standard deviation) in relation to CTP score groups A, B and C respectively (p value < 0.001). The combined CTP-IGF-1 score in comparison to the classic CTP score showed improved area under curve (0.848 and 0.854), sensitivity (71.2% and 88%), negative predictive value (41.7% and 53.7%), false negative results (49 and 19) and accuracy (75.73% and 83.98%) but decreased specificity (97.22% and 61.1%), positive predictive value (99.2% and 91.5%) and higher false positive results (1 and 14) respectively. Conclusion: IGF-1 show progressive decrements with progression of liver cirrhosis and is negatively correlated with CTP score. Addition of IGF-1 to CTP score to formulate combined score improves the AUC, sensitivity, negative predictive value and the accuracy of CTP score and decreases the false negative results.


2017 ◽  
Vol 35 (15_suppl) ◽  
pp. 11570-11570
Author(s):  
Shashank Reddy Cingam ◽  
Sean Connor ◽  
Abhishek Harshad Patel ◽  
Samip R. Master ◽  
Amol Takalkar

11570 Background: The increasing use of CT and now low-dose screening CT scans for at-risk patients have led to increasing detection of lung cancer at early stages. FDG PET/CT is used as an adjunct to conventional imaging to assess loco-regional lymph node spread. However, there is a potential for false-negative results, especially in smaller lesions or early nodal involvement. The main objective of this study was to study the value of PET/CT scan to evaluate for true negative mediastinal nodes in patients with early stage NSCLC. Accurate determination of N0 status can have a significant impact on the cost-effectiveness and timely management of early stage NSCLC. Methods: Of a total of 404 patients with NSCLC managed at our facility between 2008 to 2015, 29 adult patients whose PET scan showed no or equivocal mediastinal nodal involvement and subsequently underwent surgical exploration of mediastinal lymph nodes were included in the study. Data variables that were collected included the cancer site, date of PET, node status on PET, type and date of surgery, cancer histology, and the tissue diagnosis of the sampled nodes. SAS software was used for the analysis of the data. Results: Of the 29 patients with N0 or equivocal nodes on FDG PET/CT, 7 (24.13%) had evidence of malignancy on biopsy of the surgically resected lymph nodes. No statistically significant differences were noted between the site of the neoplastic lesion, cancer histology, duration between the date of PET and the date of surgery in the true negative (TN) and false negative (FN) groups. The recurrence rate was higher in the FN group 60 % (3/5) compared to 21 % (4/19) in the TN group who had follow up for atleast 2 years. Conclusions: Our findings suggest incidence of false negative results of FDG PET/CT for evaluation of N0 nodes in early stage NSCLC is 24.13%. This is comparatively higher than false negatives rates with mediastinoscopy (5-10%) reported in other studies. Although our sample size is small, if confirmed, such a relatively high incidence of false negative results on FDG PET/CT for N0 disease supports the current recommendations for exploratory mediastinoscopy and/or surgery for definitive staging in early stage NSCLC.


Diagnostics ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 100
Author(s):  
Victor Mihai Sacerdotianu ◽  
Bogdan Silviu Ungureanu ◽  
Sevastita Iordache ◽  
Adina Turcu-Stiolica ◽  
Antonio Facciorusso ◽  
...  

This study aimed to evaluate the diagnostic value of endoscopic ultrasound (EUS) after neoadjuvant therapy (NT) for gastric cancer restaging by meta-analysis. We conducted a systematic search of studies published on PubMed and Web of Science up to 30th August 2021. Assessing the risk of bias in the included studies was done with the QUADAS-2 tool. We used R and Review Manager 5.4.1 for calculations and statistical analysis. To evaluate the diagnostic value of EUS after NT for gastric cancer restaging, we performed a meta-analysis on six studies, with a total of 283 patients, including true-positive, true-negative, false-positive, and false-negative results for T1-T4, N0. EUS as a diagnostic test for GC patients after chemotherapy has a relatively low DOR for the T2 (3.96) and T4 stages (4.79) and a relatively high partial AUC for the T2 (0.85) and T4 (0.71) stages. Our results reveal that the pooled sensitivity for T stages after chemotherapy is rather low (29–56%), except for the T3 stage (71%). A potential limitation of our study was the small number of included studies, but no significant heterogeneity was found between them. Our meta-analysis concludes that EUS is not recommended or is still under debate for GC restaging after NT.


Author(s):  
Chandralekha Janagam ◽  
Bhagyalakshmi Atla

Background: The objectives of this study were to examine the validity of ascitic fluid cytology in the detection of pathological findings, to examine the percentage of false positive and false negative results in the cytology of ascitic fluid and to determine the validity of peritoneal cytology in relation to the histopathological type of the ovarian tumour.Methods: This retrospective study, over a period of 6 months, included 106 peritoneal cytology findings. The experimental group included 106 cytology findings obtained from patients who presented with an abdominal lump/mass with ascites and diagnosed with ovarian tumors clinically. They included 88 benign ovarian tumours (83%) and 18 malignant ovarian tumors (17%). Patients with other causes of ascites were excluded from the study.Results: The sensitivity of peritoneal cytology is 90%, specificity is 96.5%, positive predictive value is 85.7%, and negative predictive value is 97.6%. In 1.8% of patients, the peritoneal cytology showed false negative results, while in 2.8%, the results were false positive. False negative results were found in one case of teratoma with squamous cell carcinoma and one case of yolk sac tumor. False positive results were found in 2 cases of tuberculous-salpingo- oophoritis and one case of chronic salpingo-oophoritis due to reactive mesothelial proliferation, mistaken for adenocarcinoma.Conclusions: Peritoneal cytology of ascitic fluid is highly specific and sensitive for detection of ovarian malignancies, particularly in grade 3 and grade 4 disease, since most of the patients with ovarian malignancies present to us at advanced stage of the disease.


1998 ◽  
Vol 36 (4) ◽  
pp. 986-989 ◽  
Author(s):  
Nuria Mir ◽  
Miguel Sánchez ◽  
Fernando Baquero ◽  
Blanca López ◽  
Celia Calderón ◽  
...  

The early detection of colonization with methicillin-resistantStaphylococcus aureus (MRSA) of patients in intensive-care units is an essential step in the strategy for preventing MRSA epidemics. In this study, tubes containing soft salt-mannitol agar with cloxacillin (6 μg/ml) (SSMAC) were prepared for inoculation of clinical samples at patients’ bedsides by personnel of an intensive-care unit. A total of 1,914 swabs from different sample sites of 81 patients were dipped into SSMAC tubes, and after 24 h of incubation (in an incubator located near the intensive-care unit), an evident color change was considered by the intensive-care-unit personnel to be an MRSA alarm. Sixty-three (3.3%) SSMAC tubes were considered positive for MRSA, 1,827 (95.4%) were considered negative, and 24 (1.2%) were considered intermediate. Compared with values for parallel conventional surveillance cultures for MRSA, excluding tubes with intermediate results, the SSMAC test had a sensitivity of 72.7%, a specificity of 99.2%, a positive predictive value of 76.2%, and a negative predictive value of 99.0%. When intermediate tubes were considered positive, the corresponding values were 75.3, 98.2, 63.2, and 99.0%, respectively. The sensitivity and specificity values of the test to identify MRSA-colonized patients were 89.4 and 100%, respectively. Oropharyngeal and naris specimens were the most reliable samples for MRSA detection. False-negative results were frequent in bronchial aspirates with low (<103 to 106CFU/ml) MRSA counts. False-positive results were mainly due to methicillin-resistant Staphylococcus haemolyticus. The SSMAC tube is a useful, rapid, and inexpensive tool for the early identification of MRSA-colonized patients and, consequently, for the implementation of measures to prevent the spread of MRSA.


Sign in / Sign up

Export Citation Format

Share Document