Assessment of therapeutic platelet inhibition in cardiac patients: Comparative study between VerifyNow-P2Y12 and Anysis-P2Y12 assay

Author(s):  
Jinxiang Piao ◽  
Chaeyoung Yoo ◽  
SunYoung Kim ◽  
Youn-Wha Whang ◽  
Sehyun Shin ◽  
...  

BACKGROUND: Analyzing responsiveness to P2Y12 therapy is vital to preventing thrombotic and hemorrhagic complications in patients with cardiovascular diseases. OBJECTIVE: This study evaluates a new Anysis-P2Y12 assay system against VerifyNow-P2Y12 in cardiac patients and analyzes the P2Y12 low-response rates of the two devices with various cutoff values. METHODS: In total, 125 citrated blood samples were collected from cardiac patients referred for a P2Y12 antiplatelet response test. In the Anysis assay, the test result was the migration distance (MD) until the blood flow stops, which is comparable to both P2Y12 reaction units and percent inhibition obtained using VerifyNow. RESULTS: The MDs without and with P2Y12 were 182±30 and 264±12 mm, respectively (p <  0.0001). Compared to VerifyNow-P2Y12, the sensitivity and specificity of Anysis-200 were 96.8%and 88.7%, respectively. Cohen’s kappa coefficient between the two devices was 0.761, indicating a high agreement. However, there was an apparent difference in the low-response rate to P2Y12, which was 36.5%for VerifyNow and 5.9%for Anysis. CONCLUSIONS: The performance of the newly developed platelet function assay, Anysis-P2Y12 was equivalent to that of VerifyNow-P2Y12 in terms of sensitivity and specificity. The Anysis-P2Y12 assay may help screen patients with abnormal P2Y12 non-responsiveness.

1994 ◽  
Vol 33 (02) ◽  
pp. 180-186 ◽  
Author(s):  
H. Brenner ◽  
O. Gefeller

Abstract:The traditional concept of describing the validity of a diagnostic test neglects the presence of chance agreement between test result and true (disease) status. Sensitivity and specificity, as the fundamental measures of validity, can thus only be considered in conjunction with each other to provide an appropriate basis for the evaluation of the capacity of the test to discriminate truly diseased from truly undiseased subjects. In this paper, chance-corrected analogues of sensitivity and specificity are presented as supplemental measures of validity, which pay attention to the problem of chance agreement and offer the opportunity to be interpreted separately. While recent proposals of chance-correction techniques, suggested by several authors in this context, lead to measures which are dependent on disease prevalence, our method does not share this major disadvantage. We discuss the extension of the conventional ROC-curve approach to chance-corrected measures of sensitivity and specificity. Furthermore, point and asymptotic interval estimates of the parameters of interest are derived under different sampling frameworks for validation studies. The small sample behavior of the estimates is investigated in a simulation study, leading to a logarithmic modification of the interval estimate in order to hold the nominal confidence level for small samples.


2017 ◽  
Vol 20 (2) ◽  
pp. 122-127 ◽  
Author(s):  
Saverio Paltrinieri ◽  
Marco Fossati ◽  
Valentina Menaballi

Objectives The objective of this study was to evaluate the diagnostic performances of manual and instrumental measurement of reticulocyte percentage (Ret%), reticulocyte number (Ret#) and reticulocyte production index (RPI) to differentiate regenerative anaemia (RA) from non-regenerative anaemia (NRA) in cats. Methods Data from 106 blood samples from anaemic cats with manual counts (n = 74; 68 NRA, six RA) or instrumental counts of reticulocytes (n = 32; 25 NRA, seven RA) collected between 1995 and 2013 were retrospectively analysed. Sensitivity, specificity and positive likelihood ratio (LR+) were calculated using either cut-offs reported in the literature or cut-offs determined from receiver operating characteristic (ROC) curves. Results All the reticulocyte parameters were significantly higher in cats with RA than in cats with NRA. All the ROC curves were significantly different ( P <0.001) from the line of no discrimination, without significant differences between the three parameters. Using the cut-offs published in literature, the Ret% (cut-off: 0.5%) was sensitive (100%) but not specific (<75%), the RPI (cut-off: 1.0) was specific (>92%) but not sensitive (<15%), and the Ret# (cut-off: 50 × 10³/µl) had a sensitivity and specificity >80% and the highest LR+ (manual count: 14; instrumental count: 6). For all the parameters, sensitivity and specificity approached 100% using the cut-offs determined by the ROC curves. These cut-offs were higher than those reported in the literature for Ret% (manual: 1.70%; instrumental: 3.06%), lower for RPI (manual: 0.39; instrumental: 0.59) and variably different, depending on the method (manual: 41 × 10³/µl; instrumental: 57 × 10³/µl), for Ret#. Using these cut-offs, the RPI had the highest LR+ (manual: 22.7; instrumental: 12.5). Conclusions and relevance This study indicated that all the reticulocyte parameters may confirm regeneration when the pretest probability is high, while when this probability is moderate, RA should be identified using the RPI providing that cut-offs <1.0 are used.


2021 ◽  
pp. 15-17
Author(s):  
Stuti Kansra Arora ◽  
Mala Chhabra ◽  
Anuradha Anuradha ◽  
Arvind Achra ◽  
Nandini Duggal

Introduction:Hepatitis C virus (HCV) infection has emerged as one of the major global health challenge affecting about 2 - 3% of the world population. Epidemiological studies have shown that HCV infection is a major risk factor for development of Acute hepatitis,chronic liver disease,cirrhosis and Hepatocellular carcinoma (HCC).Early diagnosis of HCV is important to link hepatitis testing to care and treatment initiation. Aim:To compare sensitivity and specificity of rapid diagnostic test (RDT) with fourth generation ELISA Material and Method: This study was conducted in the Department of Microbiology at Atal Bihari Vajpayee Institute of Medical Sciences (formerly Post Graduate Institute of Medical Education and Research) and Dr Ram Manohar Lohia Hospital from January 2018 to December 2018.Blood samples of patients suspected with hepatitis were tested using ELISA and rapid diagnostic test Results: In our study 26378 blood samples were tested for HCV,using fourth generation ELISA.Of these,581(2.20%) samples were found to be positive by ELISA.These HCV positive samples along with equal number of ELISA negative samples were tested by rapid diagnostic test. Sensitivity and specificity of the rapid diagnostic test was found to be 72.98 % and 100% respectively. Discussion:Rapid diagnostic test can be used during emergency hours but their results must be followed by ELISA test results in a tertiary care hospital.Reporting of false negative results should be minimized for rapid linkage to treatment initiation and to avoid silent transmission of infection.


2020 ◽  
Vol 26 (3) ◽  
pp. 312-314
Author(s):  
Yoshifumi Uwamino ◽  
Akiko Sakai ◽  
Tomoyasu Nishimura ◽  
Masayo Noguchi ◽  
Shunsuke Uno ◽  
...  
Keyword(s):  

2015 ◽  
Vol 31 (3) ◽  
pp. 181-187 ◽  
Author(s):  
Helena Kopp Kallner ◽  
Maria Persson ◽  
Marcus Thuresson ◽  
Daniel Altman ◽  
Isaac Shemer ◽  
...  

Objectives: The aim of this study was to evaluate the diagnostic accuracy of sensitivity and specificity of cervical lesions by the low-cost, portable Gynocular colposcope and a stationary colposcope, in women referred for colposcopy with abnormal cervical cytology.Methods: A randomized cross-over clinical trial for evaluating the diagnostic accuracy in detecting cervical lesions by the Gynocular and a stationary colposcope. The Swede score systematic colposcopy system was used for evaluation of colposcopic abnormalities. Directed punch biopsy and excisional cone biopsy were used as the “gold-standard” by histologically confirmed high grade cervical lesions CIN2+ (CIN2, CIN3, CIN3+). In total, 123 women referred for colposcopy due to abnormal cervical cytology were recruited at the Department of Obstetrics and Gynecology, Danderyd Hospital, Stockholm, Sweden. The percentage agreement and the kappa statistic were calculated for Swede score by the Gynocular and a stationary colposcope. Swede scores were compared with the results from directed punch biopsy and excisional cone biopsy.Results: The Gynocular and the stationary colposcope had a high agreement of Swede scores with a Kappa statistic of 0.947, p < .0001. Punch biopsy diagnosed CIN2+ (CIN2, CIN3, and invasive cancer) in 44 (35.7 percent) women while cytology detected CIN2+ in 34 (27.6 percent) women. There were no significant differences of the sensitivity and specificity for different Swede scores by the Gynocular or a stationary colposcope in detecting CIN 2+.Conclusions: There were no significant differences in sensitivity or specificity in detecting cervical lesions by the Gynocular or stationary colposcope. The Gynocular is as accurate in diagnosing cervical lesions as a stationary colposcope.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
M Ishizawa ◽  
T Noma ◽  
S Ishikawa ◽  
K Matsunaga ◽  
R Kawakami ◽  
...  

Abstract Background Atrial fibrillation (AF) is often asymptomatic and contributes to an increased risk of strokes. The development of proper screening device of AF is unmet medical needs worldwide. Recently, we had reported that multiple measurements using Omron automated blood pressure (BP) monitor with irregular heartbeat detection showed high sensitivity and specificity for AF detection in general cardiac patients, however, this method had limitations in discriminating between AF and other arrhythmias. Purpose The aim of this study is to develop a novel program that can accurately diagnose AF by discriminating it from other arrhythmias using the pressure pulse waveform data outputted from Omron automated BP monitor. Methods In our previous clinical research, BP measurements were performed 3 times each for 303 general cardiac patients (mean age: 72.2 years, 69.8% male) with recording the real-time single lead ECG, and a total of 909 pressure pulse waveforms were obtained. Among them, 840 pressure pulse waveforms from 280 patients (include 40 AF patients) used for further analysis. We developed a program to analyze and visualize uniquely the characteristics of AF waveform through the autocorrelation-based waveform processing system produced by Melody International Ltd, Kagawa, Japan. All visualized results were judged and classified into Sinus, Non-AF and AF by two individuals blinded to the results. For each patient who obtained 3 results, a two by two contingency table was created and sensitivity, specificity, and accuracy for diagnosing AF were calculated. Results Among 840 pressure pulse waveforms, only 21 (2 Sinus and 19 Non-AF) out of 720 Sinus and Non-AF waveforms were judged as AF, and 7 out of 120 AF waveforms were judged as Non-AF. None of AF waveforms was absolutely misjudged as Sinus. In analysis for each patient, when one or more AF judgements were found in 3 waveforms, the diagnosis of AF has sensitivity and specificity of 100% and 95.8%, respectively. When two or more AF judgements were found in 3 waveforms, the diagnosis of AF has sensitivity and specificity of 100% and 97.9%, respectively. In this rule, the diagnostic accuracy of AF reached up to 98.8%, and no sinus patients were misjudged as AF. Conclusion The novel program, which applied autocorrelation methods uniquely to analysis of the pressure pulse waveforms recorded by automated BP monitor, showed high sensitivity and high specificity for AF diagnosis in general cardiac patients. This program is expected to be useful for early diagnosis for asymptomatic AF patients. Acknowledgement/Funding The present research is supported by a grant through the SCOPE from the Ministry of Internal Affairs and Communications, Japan.


2004 ◽  
Vol 21 (3) ◽  
pp. 449-453 ◽  
Author(s):  
JEFFERY K. HOVIS ◽  
SHANKARAN RAMASWAMY ◽  
MATTHEW ANDERSON

The repeatability of the D-15 color-vision test is considered to be excellent. However, this conclusion is based on a subject pool which contained a large percentage of color-normals. This type of sampling could bias the repeatability results because color-normals rarely fail the test. Furthermore, color-normals usually do not perform the D-15 in the clinical setting. To establish the repeatability of the D-15 for a relevant clinical population, we examined the D-15 results from two different sessions for 116 subjects who had a congenital red–green color-vision defect. The kappa coefficient for intersession agreement indicated that approximately 84% of the subjects obtained the same pass/fail results at both sessions. The type of defect was repeatable on approximately 80% of the subjects. Although the repeatability of the D-15 for color-defective subjects was good, it was lower than the near-perfect agreement reported previously. The coefficients of repeatability for the crossings show that if a person makes less than five crossings then the test should be administered again in order to ensure that the test result is repeatable.


Blood ◽  
2012 ◽  
Vol 120 (21) ◽  
pp. 1868-1868 ◽  
Author(s):  
Brian Tunquist ◽  
Karin Brown ◽  
Gary Hingorani ◽  
Sagar Lonial ◽  
Jonathan L. Kaufman ◽  
...  

Abstract Abstract 1868 Background ARRY-520 is a kinesin spindle protein (KSP) inhibitor that has demonstrated clinical activity in patients with relapsed and refractory multiple myeloma (MM). Although ARRY-520 is administered IV, it displays variable pharmacokinetics (PK) among patients. The degree of binding of certain drugs to serum proteins can alter their free fraction (fu) and PK, with a possible impact on clinical activity. Alpha 1-acid glycoprotein (AAG) is an acute-phase reactant protein that is often elevated in the blood of patients with cancer, including multiple myeloma. We investigated the significance of the interaction of ARRY-520 with AAG, and other relevant blood proteins, using both in vitro models and clinical data. Methods Compound-protein binding was assessed using several in vitro assays. In addition, the effect of increasing concentrations of AAG on MM cell line viability was measured. Patient data were obtained from 3 clinical studies of ARRY-520: a Phase 1 solid tumor study, a Phase 1/2 AML study, and a Phase 1/2 study in MM. The MM Phase 2 portion consists of 2 separate, 2-stage cohorts. Cohort 1 evaluated ARRY-520 administered as a single agent, and cohort 2 investigated ARRY-520 in combination with low-dose dexamethasone (LoDex). The concentrations of multiple proteins, including AAG, and the degree of ARRY-520 total protein binding, were measured in pre- and post-dose blood samples for patients in the analysis. AAG levels in MM patients were further correlated with time-on-study and clinical response rate. Results ARRY-520 exhibits low micromolar affinity for AAG in in vitro assays, but not for other common serum proteins, such as albumin. To investigate whether AAG binding impacts biological activity, we found that increasing AAG concentrations within a clinically relevant range resulted in increasing IC50 values for ARRY-520 on MM cell line viability. Of other MM agents tested, none exhibited high affinity binding to AAG in vitro, and a range of AAG concentrations did not alter the cellular activity of these compounds. Pre-dose concentrations of AAG were measured using blood samples collected from patients on all 3 ARRY-520 studies (0.4 – 4.1 g/L AAG in solid tumor study; 0.5 – 2.4 g/L in AML study; 0.2 – 2.8 g/L in MM study). Post-dose blood samples from the MM study also indicated that AAG levels do not significantly change with time. The fu of ARRY-520 in blood was meaningfully reduced among patients with the highest AAG concentrations. Furthermore, AAG and fu were correlated with changes in clinical PK: CL and Vd decreased with increasing AAG, trends consistent with a lower fu. Among the MM patients, 72 patients were evaluable for AAG determination (27 from the dose-escalation portion, 27 from Cohort 1, and 18 from Stage 1 of Cohort 2). Across all of these cohorts, the group of patients with AAG above an empirically-determined cutoff of 1.1 g/L showed a decreased median time on study (1.5 months vs 4.7 months) and no clinical responses (0/19 vs 12/53) as compared to patients below this cutoff. For example, as reported separately, ARRY-520 in combination with LoDex showed a promising 22% overall response rate (≥PR) in the 1st-stage of Cohort 2. In this cohort, 6 patients were determined to have AAG concentrations above the empirical cutoff. None of these patients had clinical benefit. Excluding these 6 patients would significantly improve the overall response rate (≥PR) from 22% (4/18) to 33% (4/12). Summary AAG has been proposed as a prognostic marker for MM disease severitya. Our preliminary data suggest that AAG levels can affect the free fraction of ARRY-520 in blood over a clinically relevant range both preclinically and in clinical studies. In retrospective analysis, patients with higher AAG levels show a lower fu and therefore may not achieve sufficient exposure to gain therapeutic benefit from ARRY-520. In preclinical analyses, this effect is specific to ARRY-520, suggesting that AAG levels may be predictive for ARRY-520 activity relative to other MM drugs. We hypothesize that prospective screening for AAG may enable exclusion of patients who may not achieve therapeutic exposure to ARRY-520, increasing the overall activity of ARRY-520 and preventing exposure of non-responders to an ineffective therapeutic dose. Further, experiments are currently underway to investigate the relevance of other acute-phase proteins in blood. Disclosures: Tunquist: Array BioPharma: Employment. Off Label Use: ARRY-520 alone and with dexamethasone for the treatment of relapsed/refractory multiple myeloma. ARRY-520 is not currently approved for any indication. Brown:Array BioPharma: Employment. Hingorani:Array BioPharma: Employment. Lonial:Millennium Pharmaceuticals, Inc.: Consultancy, Membership on an entity's Board of Directors or advisory committees; Celgene: Consultancy, Membership on an entity's Board of Directors or advisory committees; Bristol-Meyers Squibb: Consultancy, Membership on an entity's Board of Directors or advisory committees; Novartis: Consultancy, Membership on an entity's Board of Directors or advisory committees; Onyx: Consultancy, Membership on an entity's Board of Directors or advisory committees; Merck: Consultancy, Membership on an entity's Board of Directors or advisory committees. Kaufman:Millenium: Consultancy; Celgene: Consultancy; Novartis: Consultancy; Onyx: Consultancy. Zonder:Celgene: Honoraria, Research Funding; Millenium: Honoraria, Research Funding. Orlowski:Array BioPharma: Honoraria, Membership on an entity's Board of Directors or advisory committees. Shah:Array BioPharma: Honoraria, Membership on an entity's Board of Directors or advisory committees, Research Funding; Celgene: Honoraria, Membership on an entity's Board of Directors or advisory committees, Research Funding; Onyx: Honoraria, Research Funding, Speakers Bureau; Novartis: Honoraria, Research Funding, Speakers Bureau. Hilder:Array BioPharma: Employment. Ptaszynski:Array BioPharma: Consultancy. Koch:Array BioPharma: Employment. Litwiler:Array BioPharma: Employment. Walker:Array BioPharma: Employment.


2015 ◽  
Vol 51 (5) ◽  
pp. 306-310 ◽  
Author(s):  
Lauren Cunningham ◽  
Audrey Cook ◽  
Andrew Hanzlicek ◽  
Kenneth Harkin ◽  
Joseph Wheat ◽  
...  

The objective of this study was to evaluate the sensitivity and specificity of an antigen enzyme immunoassay (EIA) on urine samples for the diagnosis of histoplasmosis in dogs. This retrospective medical records review included canine cases with urine samples submitted for Histoplasma EIA antigen assay between 2007 and 2011 from three veterinary institutions. Cases for which urine samples were submitted for Histoplasma antigen testing were reviewed and compared to the gold standard of finding Histoplasma organisms or an alternative diagnosis on cytology or histopathology. Sensitivity, specificity, negative predictive value, positive predictive value, and the kappa coefficient and associated confidence interval were calculated for the EIA-based Histoplasma antigen assay. Sixty cases met the inclusion criteria. Seventeen cases were considered true positives based on identification of the organism, and 41 cases were considered true negatives with an alternative definitive diagnosis. Two cases were considered false negatives, and there were no false positives. Sensitivity was 89.47% and the negative predictive value was 95.35%. Specificity and the positive predictive value were both 100%. The kappa coefficient was 0.9207 (95% confidence interval, 0.8131–1). The Histoplasma antigen EIA test demonstrated high specificity and sensitivity for the diagnosis of histoplasmosis in dogs.