scholarly journals Rapid detection of health-care-associated bloodstream infection in critical care using multipathogen real-time polymerase chain reaction technology: a diagnostic accuracy study and systematic review

2015 ◽  
Vol 19 (35) ◽  
pp. 1-142 ◽  
Author(s):  
Geoffrey Warhurst ◽  
Graham Dunn ◽  
Paul Chadwick ◽  
Bronagh Blackwood ◽  
Daniel McAuley ◽  
...  

BackgroundThere is growing interest in the potential utility of real-time polymerase chain reaction (PCR) in diagnosing bloodstream infection by detecting pathogen deoxyribonucleic acid (DNA) in blood samples within a few hours. SeptiFast (Roche Diagnostics GmBH, Mannheim, Germany) is a multipathogen probe-based system targeting ribosomal DNA sequences of bacteria and fungi. It detects and identifies the commonest pathogens causing bloodstream infection. As background to this study, we report a systematic review of Phase III diagnostic accuracy studies of SeptiFast, which reveals uncertainty about its likely clinical utility based on widespread evidence of deficiencies in study design and reporting with a high risk of bias.ObjectiveDetermine the accuracy of SeptiFast real-time PCR for the detection of health-care-associated bloodstream infection, against standard microbiological culture.DesignProspective multicentre Phase III clinical diagnostic accuracy study using the standards for the reporting of diagnostic accuracy studies criteria.SettingCritical care departments within NHS hospitals in the north-west of England.ParticipantsAdult patients requiring blood culture (BC) when developing new signs of systemic inflammation.Main outcome measuresSeptiFast real-time PCR results at species/genus level compared with microbiological culture in association with independent adjudication of infection. Metrics of diagnostic accuracy were derived including sensitivity, specificity, likelihood ratios and predictive values, with their 95% confidence intervals (CIs). Latent class analysis was used to explore the diagnostic performance of culture as a reference standard.ResultsOf 1006 new patient episodes of systemic inflammation in 853 patients, 922 (92%) met the inclusion criteria and provided sufficient information for analysis. Index test assay failure occurred on 69 (7%) occasions. Adult patients had been exposed to a median of 8 days (interquartile range 4–16 days) of hospital care, had high levels of organ support activities and recent antibiotic exposure. SeptiFast real-time PCR, when compared with culture-proven bloodstream infection at species/genus level, had better specificity (85.8%, 95% CI 83.3% to 88.1%) than sensitivity (50%, 95% CI 39.1% to 60.8%). When compared with pooled diagnostic metrics derived from our systematic review, our clinical study revealed lower test accuracy of SeptiFast real-time PCR, mainly as a result of low diagnostic sensitivity. There was a low prevalence of BC-proven pathogens in these patients (9.2%, 95% CI 7.4% to 11.2%) such that the post-test probabilities of both a positive (26.3%, 95% CI 19.8% to 33.7%) and a negative SeptiFast test (5.6%, 95% CI 4.1% to 7.4%) indicate the potential limitations of this technology in the diagnosis of bloodstream infection. However, latent class analysis indicates that BC has a low sensitivity, questioning its relevance as a reference test in this setting. Using this analysis approach, the sensitivity of the SeptiFast test was low but also appeared significantly better than BC. Blood samples identified as positive by either culture or SeptiFast real-time PCR were associated with a high probability (> 95%) of infection, indicating higher diagnostic rule-in utility than was apparent using conventional analyses of diagnostic accuracy.ConclusionSeptiFast real-time PCR on blood samples may have rapid rule-in utility for the diagnosis of health-care-associated bloodstream infection but the lack of sensitivity is a significant limiting factor. Innovations aimed at improved diagnostic sensitivity of real-time PCR in this setting are urgently required. Future work recommendations include technology developments to improve the efficiency of pathogen DNA extraction and the capacity to detect a much broader range of pathogens and drug resistance genes and the application of new statistical approaches able to more reliably assess test performance in situation where the reference standard (e.g. blood culture in the setting of high antimicrobial use) is prone to error.Study registrationThe systematic review is registered as PROSPERO CRD42011001289.FundingThe National Institute for Health Research Health Technology Assessment programme. Professor Daniel McAuley and Professor Gavin D Perkins contributed to the systematic review through their funded roles as codirectors of the Intensive Care Foundation (UK).

Author(s):  
Jade Bokma ◽  
Nick Vereecke ◽  
Mathilde L. Pas ◽  
Laurens Chantillon ◽  
Marianne Vahl ◽  
...  

Rapid identification of Mycoplasma bovis infections in cattle is a key factor to guide antimicrobial therapy and biosecurity measures. Recently, nanopore sequencing became an affordable diagnostic tool for both clinically relevant viruses and bacteria, but the diagnostic accuracy for M. bovis identification is undocumented. Therefore, in this study nanopore sequencing was compared to rapid identification of M. bovis with MALDI-TOF MS (RIMM), and triplex real-time PCR in a Bayesian latent class model (BLCM) for M. bovis in bronchoalveolar lavage fluid (BALf) obtained from calves. In practice, pooling of samples is often used to save money, but the influence on diagnostic accuracy has not been described for M. bovis . Therefore, a convenience sample of 17 pooled samples containing 5 individual BALf samples per farm was analyzed as well. The results of the pooled samples were compared to the individual samples, to determine sensitivity (Se) and specificity (Sp). The BLCM showed a good Se (77.3%; 95% Credible Interval: 57.8%-92.8%) and high Sp (97.4%; 91.5%-99.7%) for nanopore sequencing compared to RIMM (Se: 93.0%; 76.8%-99.5%, Sp: 91.3; 82.5%-97.0%) and real-time PCR (Se: 94.6%; 89.7%-97.7%, Sp: 86.0%; 76.1-93.6%). Se and Sp of pooled analysis for M. bovis were 85.7% (95% confidence interval: 59.8-111.6%) and 90.0% (71.4-108.6%%) for nanopore sequencing and 100% (100%-100%) and 88.9% (68.4-109.4%) for RIMM, respectively. In conclusion, nanopore sequencing is a rapid, reliable tool for the identification of M. bovis . To reduce costs and increase the chance of M. bovis identification, pooling of 5 samples for nanopore sequencing and RIMM is possible.


2014 ◽  
Vol 41 (1) ◽  
pp. 86-93 ◽  
Author(s):  
Geoffrey Warhurst ◽  
Satanayarana Maddi ◽  
Graham Dunn ◽  
Murad Ghrew ◽  
Paul Chadwick ◽  
...  

2019 ◽  
Vol 5 (3) ◽  
pp. 86 ◽  
Author(s):  
Fuchs ◽  
Lass-Flörl ◽  
Posch

Candidemia poses a major threat to ICU patients and is routinely diagnosed by blood culture, which is known for its low sensitivity and long turnaround times. We compared the performance of a novel, Candida-specific multiplex real-time PCR assay (Fungiplex® Candida IVD Real-Time PCR Kit) with blood culture and another established diagnostic real-time PCR assay (LightCycler SeptiFast Test) with respect to Candida detection from whole blood samples. Clinical samples from 58 patients were analyzed by standard blood culture (BC) and simultaneously tested with the Fungiplex Candida PCR (FP) and the SeptiFast test (SF) for molecular detection of Candida spp. Compared to BC, the FP test showed high diagnostic power, with a sensitivity of 100% and a specificity of 94.1%. Overall diagnostic accuracy reached 94.6%. Using SF, we found a sensitivity of 60%, a specificity of 96.1%, and an overall diagnostic accuracy of 92.9%. The Fungiplex Candida PCR has shown good sensitivity and specificity on clinical samples of high-risk patients for direct detection of Candida species in whole blood samples. Together with conventional diagnostics (BC and antigen testing), this new multiplex PCR assay may contribute to a rapid and accurate diagnosis of candidiasis.


Pathogens ◽  
2021 ◽  
Vol 10 (6) ◽  
pp. 656
Author(s):  
Konstantin Tanida ◽  
Andreas Hahn ◽  
Kirsten Alexandra Eberhardt ◽  
Egbert Tannich ◽  
Olfert Landt ◽  
...  

Microsporidiosis is an infection predominantly occurring in immunosuppressed patients and infrequently also in travelers. This study was performed to comparatively evaluate the diagnostic accuracy of real-time PCR assays targeting microsporidia with etiological relevance in the stool of human patients in a latent class analysis-based test comparison without a reference standard with perfect accuracy. Thereby, two one-tube real-time PCR assays and two two-tube real-time PCR assays targeting Enterocytozoon bieneusi and Encephalocytozoon spp. were included in the assessment with reference stool material (20), stool samples from Ghanaian HIV-positive patients (903), and from travelers, migrants and Colombian indigenous people (416). Sensitivity of the assays ranged from 60.4% to 97.4% and specificity from 99.1% to 100% with substantial agreement according to Cohen’s kappa of 79.6%. Microsporidia DNA was detected in the reference material and the stool of the HIV patients but not in the stool of the travelers, migrants, and the Colombian indigenous people. Accuracy-adjusted prevalence was 5.8% (n = 78) for the study population as a whole. In conclusion, reliable detection of enteric disease-associated microsporidia in stool samples by real-time PCR could be demonstrated, but sensitivity between the compared microsporidia-specific real-time PCR assays varied.


2021 ◽  
Vol 11 (5) ◽  
pp. 2313
Author(s):  
Inho Lee ◽  
Nakkyun Park ◽  
Hanbee Lee ◽  
Chuljin Hwang ◽  
Joo Hee Kim ◽  
...  

The rapid advances in human-friendly and wearable photoplethysmography (PPG) sensors have facilitated the continuous and real-time monitoring of physiological conditions, enabling self-health care without being restricted by location. In this paper, we focus on state-of-the-art skin-compatible PPG sensors and strategies to obtain accurate and stable sensing of biological signals adhered to human skin along with light-absorbing semiconducting materials that are classified as silicone, inorganic, and organic absorbers. The challenges of skin-compatible PPG-based monitoring technologies and their further improvements are also discussed. We expect that such technological developments will accelerate accurate diagnostic evaluation with the aid of the biomedical electronic devices.


Sign in / Sign up

Export Citation Format

Share Document