scholarly journals Comparison of the accuracy of fixture-level impression making after splinting prosthetic components

2020 ◽  
Vol 10 (2) ◽  
pp. 5252-5258

Considering the effects of different impression-taking techniques on the dimensional accuracy of the final cast and controversies over the best technique in implant dentistry, the present study was undertaken to evaluate the effects of three different open-tray impression techniques on the dimensional accuracy of final casts for implants. A two-piece metallic index was prepared and a patient’s jaw was simulated by placing self-cured acrylic resin in the lower part of the index. Then 2 holes were produced in the acrylic resin at a specific distance from each other, and the analogs were placed in these holes. Three different open-tray impression techniques were evaluated using the upper segment of the index, which mimicked the specific tray. The dimensional accuracy of the casts was evaluated by comparing the distances between the predetermined points on the implant analogs and the positions of the points with similar distances on the master model. A digital caliper (accurate to 0.01 mm) was used to measure the distances. The differences in the measurements on the final casts were analyzed with SPSS 16, using Kruskal-Wallis test. Post hoc Mann-Whitney U test was used for two-by-two comparisons. There was a significant difference between the group in which the analogs and impression copings were not splinted and the group with impression coping splinting without analog splinting and the group with simultaneous splinting of the impression copings and implant analogs, in relation to distances between similar points on the master model. In this context, the second and third techniques better reconstructed the positions of the points. Splinting of impression copings with Duralay acrylic resin prevented the movement of impression copings during the impression-taking procedure and despite an increase in the accuracy of impression taking during splinting of analogs by Duralay acrylic resin, the increase in accuracy was not significant statistically; therefore, splinting of the impression copings without splinting of the analogs is recommended due to an increase in impression-taking accuracy and facilitation of laboratory procedures.

2015 ◽  
Vol 1 (1) ◽  
pp. 102
Author(s):  
Pramudya Aditama ◽  
Siti Sunarintyas ◽  
Widjijono Widjijono

Resin akrilik merupakan bahan yang sering digunakan dalam pembuatan basis gigi tiruan. Kelemahan resin akrilik adalah mudah patah. Salah satu cara untuk mengatasi masalah tersebut adalah dengan menambahkan polyethylene (PE) atau glass fiber. Tujuan dari penelitian ini untuk mengetahui pengaruh jenis dan volumetrik fiber terhadap kekuatan transversal reparasi plat resin akrilik. Penelitian ini menggunakan dua puluh lima plat resin akrilik kuring panas berukuran 65 x 10 x 2,5 mm. Subjek dipreparasi untuk membuat jarak 3 mm dan sudut bevel 45o. Subjek dibagi menjadi 5 kelompok, masingmasing kelompok terdiri dari 5 subjek. Kelompok 1 (kontrol) tanpa penambahan fiber, kelompok II dengan penambahan 3,7% v/v PE fiber, kelompok III dengan penambahan 7,4% v/v PE fiber, kelompok IV dengan penambahan 3,7% v/v E-glass fiber, dan kelompok V dengan penambahan 7,4% v/v E-glass fiber. Seluruh plat direndam dalam air destilasi selama satu hari pada suhu 37oC. Pengujian kekuatan transversal plat resin akrilik dengan menggunakan Universal Testing Machine dan data yang didapat dianalisis menggunakan ANAVA dua jalur dengan tingkat kepercayaan 95%. Rerata kekuatan transversal (MPa) reparasi plat resin akrilik yang diperkuat fiber: 3,7% v/v PE fiber (67,77±3,34); 7,4% v/v PE fiber (80,37±8,42); 3,7% v/v E-glass fiber (96,72±5,43); 7,4% v/v E-glass fiber (109,44±4,98); sedangkan reparasi plat resin yang tidak diperkuat fiber menghasilkan kekuatan transversal 56,27±4,7 MPa. Hasil analisis menggunakanANAVA dua jalur menunjukkan variabel jenis dan volumetrik fiber memberikan pengaruh signifikan (p<0,05), sedangkan interaksi antara jenis dan volumetrik fiber tidak berpengaruh signifikan (p>0,05). Uji post hoc Tukey menunjukkan perbedaan signifikan (p<0,05) untuk seluruh kelompok perlakuan. Penambahan E-glass fiber dalam reparasi plat resinakrilik mampu meningkatkan kekuatan transversal lebih tinggi dibandingkan dengan menggunakan PE fiber. Peningkatan volumetrik fiber dapat meningkatkan kekuatan transversal reparasi plat resin akrilik. Effect Of Type And Volumetric Fiber On Transverse Strength Of Acrylic Resin Plate Repair. Acrylic resin is the most common denture base material. A disadvantage of acrylic resin is that it is easily fractured. One way to resolve this problem is by adding polyethylene (PE) or glass fibers. The purpose of this research is to find out about the effect of type and volumetric fiber on transverse strength of acrylic resin plate repaired. The experiment involved twenty five plates of heat cured acrylic with the dimensions of 65 x 10 x 2.5 mm. The speciments were prepared to create a 3 mm gap and 45° bevel. The subjects were divided into 5 groups; each group consisted of 5. Group I (control) was without fiber reinforcement, group II reinforced with 3.7% v/v PE fiber, group III reinforced with 7.4% v/v PE fiber, group IV reinforced with 3.7% v/v E-glass fiber, and group V reinforced with 7.4% v/v E-glass fiber. All plates were soaked in distilled water for one day at 37° C temperature. The plates were tested for transverse strength with Universal Testing Machine and all data obtained were analyzed with two way ANOVA at 95% confidence level. The mean of transverse strength (MPa) of the acrylic resin plate repair reinforced with fiber: 3.7% v/v PE fiber was (67.77±3.34); 7.4% v/v PE fiber (80.37±8.42); 3.7% v/v E-glass fiber (96.72±5.43); 7.4% v/v E-glass fiber (109.44±4.98); while the transverse strength of the acrylic resin plate with no fiber reinforced was 56.27±4.7 MPa. Two way ANOVA analysis shows that type and volumetric fiber had significant effect (p<0.05), while the interaction between type and volumetric fiber had no significant effect (p>0.05). Tukey post hoc test shows significant difference (p<0.05) for all groups. The addition of E-glass fibers in the acrylic resin plate repaired increased the transverse strength higher than that with PE fibers. The increase in volumetric fibers might improve the transverse strength of the acrylic resin plate repaired.


2021 ◽  
Vol 6 (2) ◽  
pp. 71
Author(s):  
Rudy S ◽  
Titik Ismiyati ◽  
Endang Wahyuningtyas

Heat cured acrylic resin is the most commonly used denture base materials.  Zirconium dioxide (ZrO2) nanoparticles can be applied as additional filler to increase mechanical strength and to reduce the amount of residual monomer. The aim of this research is to analyze the effect of ZrO2 nanoparticles concentrations as filler on heat cured acrylic resin denture base toward viability of fibroblast cells. Twenty four disc-shaped heat cured acrylic resin plate (diameter 5 mm; width 2 mm), were divided into 4 groups (n=6), they were consisted of group I control (acrylic resin), group II acrylic resin with 2.5% ZrO2, group III acrylic resin with 5% ZrO2, and group IV acrylic resin with 7.5% ZrO2. Cell viability was obtained using MTT assay and ELISA plate reader. The result is examined with one way ANOVA followed by LSD post hoc assessment. The result showed highest cell viability percentage on experimental group of 2.5% ZrO2 with value as high as 97.49%. One way ANOVA test and LSD post hoc test showed a significant difference between groups (p<0.05). The conclusion of this research is ZrO2 nanoparticles concentration utilized as filler on heat cured acrylic resin denture base is effect to viability of fibroblast cells, and ZrO2 nanoparticles 2.5% shows the highest viability of fibroblast cell compared to 5% and 7.5% ZrO2 nanoparticles concentrations  


2008 ◽  
Vol 9 (6) ◽  
pp. 49-56 ◽  
Author(s):  
Ramin Mosharraf ◽  
Sina Shafa ◽  
Zeinab Zaree

Aim In addition to the impression material, the type of impression tray influences the accurate dimensional transfer of the size and position of the teeth to the master cast. The aim of this study was to determine the accuracy of master casts produced from an alginate impression material using a visible-light-curing resin and autopolymerizing polymethyl methacrylate resin custom tray materials. Methods and Materials Two types of custom trays were fabricated from a stainless steel master model with three index studs. Twenty-two irreversible hydrocolloid impressions were made of the master model and then poured with a Type III dental stone. The distances between the reproduced index studs were measured to +/- 0.01 mm with a digital caliper. A one-way analysis of variance (ANOVA) and T-test were used for data analysis. Results There were no significant differences between the two tray materials for any of the three distances. There were no statistical differences between the master model and the casts made from the two tray materials in the length dimension, but there were significant differences in the vertical dimension. In terms of the width dimension there was a significant difference only between the cold curing group and the master model. Conclusion Within the limitations of this study, the dimensions of stone casts poured from an impression made using a light-cured tray did not differ significantly from those created from impressions made using autopolymerizing acrylic trays. However, working dies from the light-curing tray impressions were more accurate buccolingually than those from the autopolymerizing acrylic trays. Clinical Significance The accuracy of master cast reproduction using visible-light-curing resin or an autopolymerizing polymethyl methacrylate resin custom tray material is acceptable. Although autopolymerizing resin materials require less equipment and are relatively more inexpensive, light-cure tray materials may be the material of choice for custom tray fabrication due to greater accuracy in the buccolingual dimension. Citation Shafa S, Zaree Z, Mosharraf R. The Effects of Custom Tray Material on the Accuracy of Master Casts. J Contemp Dent Pract 2008 September; (9)6:049-056.


2017 ◽  
Vol 16 ◽  
pp. 1-7
Author(s):  
Bruna Lorena dos Santos Oliveira ◽  
Ana Rosa Costa ◽  
Américo Bortolazzo Correr ◽  
Marcus Vinicius Crepaldi ◽  
Lourenço Correr-Sobrinho ◽  
...  

Aim: To evaluate, in vitro, the effect of adhesive and bonding materials on the shear bond strength (SBS) of metallic brackets bonded to bovine teeth. Methods: Bovine teeth were embedded with acrylic resin, etched with 35% phosphoric acid for 20 s, rinsed, dried for 20 s and divided into 8 groups (n=20), according to the bonding materials and adhesive: Groups 1 and 5 – Transbond XT; Groups 2 and 6 – Fill Magic; Groups 3 and 7 – Biofix; and, Groups 4 and 8 – Orthocem. One layer of adhesive 3 M Unitek (Group 1), and one layer of Single Bond Universal Adhesive (Groups 2, 3 and 4) were applied and light-cured with LED for 10 s. Brackets were bonded to the buccal surface with four bonding materials and light-cured with LED for 40 s. SBS was carried out after 24 h and thermocycling (7,000 cycles - 5°/55 °C). Data were submitted to two way ANOVA and Tukey’s post hoc test (α=0.05). The Adhesive Remaining Index (ARI) was evaluated at 8×. Results: The adhesive was effective in increasing the SBS for all bonding materials (p<0.05). Significant difference (p<0.05) on the SBS was observed between bonding materials with or without adhesive. The ARI showed a predominance of scores 0 for all groups. Conclusions: The adhesive improved significantly the SBS of the brackets to teeth. Different SBS values occurred among the bonding materials. ARI index showed predominance of score 0 for all groups.


2016 ◽  
Vol 2016 ◽  
pp. 1-6 ◽  
Author(s):  
Mohammed Gad ◽  
Aws S. ArRejaie ◽  
Mohamed Saber Abdel-Halim ◽  
Ahmed Rahoma

Objective.The aim of this study was to evaluate the effect of incorporation of glass fiber, zirconia, and nano-zirconia on the transverse strength of repaired denture base.Materials and Methods.Eighty specimens of heat polymerized acrylic resin were prepared and randomly divided into eight groups (n=10): one intact group (control) and seven repaired groups. One group was repaired with autopolymerized resin while the other six groups were repaired using autopolymerized resin reinforced with 2 wt% or 5 wt% glass fiber, zirconia, or nano-zirconia particles. A three-point bending test was used to measure the transverse strength. The results were analyzed using SPSS and repeated measure ANOVA and post hoc least significance (LSD) test (P≤0.05).Results.Among repaired groups it was found that autopolymerized resin reinforced with 2 or 5 wt% nano-zirconia showed the highest transverse strength (P≤0.05). Repairs with autopolymerized acrylic resin reinforced with 5 wt% zirconia showed the lowest transverse strength value. There was no significant difference between the groups repaired with repair resin without reinforcement, 2 wt% zirconia, and glass fiber reinforced resin.Conclusion.Reinforcing of repair material with nano-zirconia may significantly improve the transverse strength of some fractured denture base polymers.


2016 ◽  
Vol 17 (9) ◽  
pp. 734-739
Author(s):  
Mohammed E Sayed ◽  
Bandar MA Al-Makramani ◽  
Fuad A Al-Sanabani ◽  
Mohamed S Mohamed

ABSTRACT Aim The aim of this study was to evaluate the effect of intermixing brands of addition silicone impression materials on the dimensional accuracy of stone models using two-step putty-wash technique. Materials and methods Two common brands of addition silicone impression material (Express and Aquasil) were used in this study. A total of 40 impressions of a stainless steel model simulating a three-unit bridge were made, 10 impressions for each group. Accuracy was assessed by measuring two dimensions (inter-abutment and intra-abutment) on stone models obtained from impressions of the stainless steel model. Each sample was measured thrice and the mean value was calculated. The data were analyzed using analysis of variance (ANOVA) and Scheffe's post hoc test. Results The results indicated that each of the inter-abutment and intra-abutment dimensions of the stone models was significantly higher than those for the stainless steel model (p < 0.001). However, there was no statistically significant difference in each of the inter-abutment and intra-abutment dimensions of the stone models among the four tested groups (p < 0.05). Conclusion The results obtained were statistically analyzed and the values of the inter-abutment and intra-abutment dimensions were all within the clinically acceptable range. Clinical significance Intermixing brands of additional silicone impression materials evaluated in this study did not affect the dimensional accuracy of obtained stone casts. This will help to minimize the wastage of materials due to lack of either light or putty consistency of the same brand of additional silicone impression material. How to cite this article Sayed ME, Al-Makramani BMA, Al-Sanabani FA, Mohamed MS. Effect of Intermixing Brands on the Dimensional Accuracy of Master Cast using Putty-wash Impression Technique. J Contemp Dent Pract 2016;17(9):734-739.


2020 ◽  
Vol 2020 ◽  
pp. 1-9 ◽  
Author(s):  
Pokpong Amornvit ◽  
Sasiwimol Sanohkan ◽  
Chaimongkon Peampring

There are various scanners available in dental practice with various accuracies. The aim of this study was to compare the 3D capturing accuracy of scans obtained from Trios 3 and Dental Wings scanner. A reference mandibular model was printed from FormLab with reference points in three axes (X, Y, and XY and Z). The printed model was scanned 5 times with 3 scans: normal scan by Trios 3 (Trios 3A), high-resolution scan by Trios 3 (Trios 3B), and normal scan by Dental Wings. After scan, the stereolithography (stl) files were generated. Then, the measurements were made from the computer software using Rhinoceros 3D (Rhino, Robert McNeel & Associates for Windows, Washington DC, USA). The measurements made with digital caliper were taken as control. Statistical analysis was done using one-way ANOVA with post hoc using Sheffe (P<0.01). Trios 3 presented higher accuracy than Dental Wings and high resolution showed better results. The Dental Wings showed less accuracy at the measurements >50 mm of length and >30 mm in width. There was no significant difference (P>0.05) of control with the Trios 3A and Trios 3B. Similarly, for the measurements in Z-axis, there was no significant difference of control with each scan (Trios 3A, Trios 3B, and Dental Wings). Accuracy of the scan is affected by the length of the scanning area and scanning pattern. It is less recommended to Dental Wings scan >3-unit prosthesis and that crosses the midline.


2004 ◽  
Vol 15 (1) ◽  
pp. 63-67 ◽  
Author(s):  
Rafael Leonardo Xediek Consani ◽  
Saide Sarckis Domitti ◽  
Marcelo Ferraz Mesquita ◽  
Simonides Consani

This study investigated the dimensional stability of denture bases influenced by packing methods, in relation to post-pressing times, in the Clássico acrylic resin which was prepared according to manufacturer recommendations. Forty maxillary wax bases were made and randomly assigned into 2 groups of 20 specimens each according to the conventional and RS system packing methods. In each method, the specimens were subdivided into immediate, 6, 12 and 24 h post-pressing times. The dough of the acrylic resin was packed in metallic flasks and processed in a water bath curing cycle at 74ºC for 9 h. After cooling at room temperature, the bases were removed from the flasks, finished and fixed on stone casts with instantaneous adhesive. The resin base-stone cast sets were transversally sectioned into 3 sections and the base-stone gap measured at 5 points in each section. The data were submitted to ANOVA and Tukey's test, which showed that the RS system had a smaller base distortion compared to conventional packing, with the exception of the 24-h post-pressing time. There was a statistically significant difference between the packing methods only in section C (posterior palatal zone). In the conventional packing method, the immediate and 6 h times demonstrated values with no statistically significant difference between them, as well as between the 12 and 24 h post-pressing times.


2016 ◽  
Vol 3 (2) ◽  
pp. 128
Author(s):  
Aprilia Dian Fatimina ◽  
Benni Benyamin ◽  
Helmi Fathurrahman

Background: One of factor that increases the flexural strenght of fiberreinforced acrylic resin is a fiberglass position . Fiberglass is one of type that can be used in dentistry. The aim of this was to determine the influence of position of fiberglass to the flexural strenght of fiber reinforced acrylic resin.Method: This study was in vitro laboratory experimental. Samples was 16plate spesimens (65x10x2.5mm). The study group was divided into 4 group : 3 groups of fiber reinforced acrylic resin were given fiberglass at the upper, middle, and bottom side and 1 control group of resin acrylic without fiberglass. All of groups would be in the flexural strenght test with a three-point bending test using a universal testing machine.Result: Based on One Way ANOVA test showed that there were significantvalue 0.000 (p<0.05), it concluded that there were significant influencebetween all the groups. Based on the LSD Post Hoc test showed that therewere significant value between all of groups with fiberglass reinforced andcontrol group without fiberglass reinforced. Comparisson between the group that given fiberglass in a upper and middle side with the group that given in bottom side showed value of significant difference (p < 0.05).Conclusion: The result of study was concluded that there was an influenceon the position of fiberglass to flexural strenght of fiber reinforced acrylic resin


RSBO ◽  
2019 ◽  
Vol 15 (2) ◽  
pp. 77
Author(s):  
Lidia Olga Bach Pinheiro ◽  
Alfonso Sanchez Ayala ◽  
Marcos Cezar Pomini ◽  
Vanessa Taborda da Cruz ◽  
Ingrid Viel del Farias ◽  
...  

Irreversible hydrocolloids have been used in dental practice for decades and their pouring time has been suggested to be as short as possible; however the latest generation of alginates exhibit better properties, which could influence the fidelity of the casts. Objective: To evaluate the linear dimensional stability of stone casts obtained using two irreversible hydrocolloid brands (Cavex ColorChange and Jeltrate) after disinfection. Material and methods: Samples were divided into 16 groups (n = 10) according to brand, storage time and disinfection. Impressions were taken of a metallic master model made of stainless steel with two abutments. Cast models were obtained using type IV gypsum, after disinfection with sodium hypochlorite at 1% or without any disinfection followed by storage for four different times (immediate pouring, and after 24, 72 or 120 hours storage after obtaining the impressions) and the models were measured with a digital caliper. Data were submitted to ANOVA 3-way followed by Tukey’s test (α < 0.05). Results: A statistically significant difference was detected with Jeltrate Plus after 72 and 120 hours in storage (with and without disinfection), as well as Cavex without disinfection. Differences were found for Cavex with disinfection/24 hours storage, when compared to immediate pouring (P < 0.05). The alginates presented similar behavior regarding disinfection for the same time (P > 0.05). Conclusion: Storage longer than 24 hours affects the fidelity of casts. Disinfection does not promote significant alteration at any of the experimental times with either material.


Sign in / Sign up

Export Citation Format

Share Document