scholarly journals MRI Radiomics in Prostate Cancer: A Reliability Study

2021 ◽  
Vol 11 ◽  
Author(s):  
Fabrizio Urraro ◽  
Valerio Nardone ◽  
Alfonso Reginelli ◽  
Carlo Varelli ◽  
Antonio Angrisani ◽  
...  

BackgroundRadiomics can provide quantitative features from medical imaging that can be correlated to clinical endpoints. The challenges relevant to robustness of radiomics features have been analyzed by many researchers, as it seems to be influenced by acquisition and reconstruction protocols, as well as by the segmentation of the region of interest (ROI). Prostate cancer (PCa) represents a difficult playground for this technique, due to discrepancies in the identification of the cancer lesion and the heterogeneity of the acquisition protocols. The aim of this study was to investigate the reliability of radiomics in PCa magnetic resonance imaging (MRI).MethodsA homogeneous cohort of patients with a PSA rise that underwent multiparametric MRI imaging of the prostate before biopsy was tested in this study. All the patients were acquired with the same MRI scanner, with a standardized protocol. The identification and the contouring of the region of interest (ROI) of an MRI suspicious cancer lesion were done by two radiologists with great experience in prostate cancer (>10 years). After the segmentation, the texture features were extracted with LIFEx. Texture features were then tested with intraclass coefficient correlation (ICC) analysis to analyze the reliability of the segmentation.ResultsForty-four consecutive patients were included in the present analysis. In 26 patients (59.1%), the prostate biopsy confirmed the presence of prostate cancer, which was scored as Gleason 6 in 6 patients (13.6%), Gleason 3 + 4 in 8 patients (18.2%), and Gleason 4 + 3 in 12 patients (27.3%). The reliability analysis conversely showed poor reliability in the majority of the MRI acquisition (61% in T2, 89% in DWI50, 44% in DWI400, and 83% in DWI1,500), with ADC acquisition only showing better reliability (poor reliability in only 33% of the texture features).ConclusionsThe low ratio of reliability in a monoinstitutional homogeneous cohort represents a significant alarm bell for the application of MRI radiomics in the field of prostate cancer. More work is needed in a clinical setting to further study the potential of MRI radiomics in prostate cancer.

2019 ◽  
Vol 40 (9) ◽  
pp. 1869-1878 ◽  
Author(s):  
Doeschka A Ferro ◽  
Henri JJM Mutsaerts ◽  
Saima Hilal ◽  
Hugo J Kuijf ◽  
Esben T Petersen ◽  
...  

Cerebral cortical microinfarcts (CMIs) are small ischemic lesions associated with cognitive impairment and dementia. CMIs are frequently observed in cortical watershed areas suggesting that hypoperfusion contributes to their development. We investigated if presence of CMIs was related to a decrease in cerebral perfusion, globally or specifically in cortex surrounding CMIs. In 181 memory clinic patients (mean age 72 ± 9 years, 51% male), CMI presence was rated on 3-T magnetic resonance imaging (MRI). Cerebral perfusion was assessed from cortical gray matter of the anterior circulation using pseudo-continuous arterial spin labeling parameters cerebral blood flow (CBF) (perfusion in mL blood/100 g tissue/min) and spatial coefficient of variation (CoV) (reflecting arterial transit time (ATT)). Patients with CMIs had a 12% lower CBF (beta = −.20) and 22% higher spatial CoV (beta = .20) (both p < .05) without a specific regional pattern on voxel-based CBF analysis. CBF in a 2 cm region-of-interest around the CMIs did not differ from CBF in a reference zone in the contralateral hemisphere. These findings show that CMIs in memory clinic patients are primarily related to global reductions in cerebral perfusion, thus shedding new light on the etiology of vascular brain injury in dementia.


2021 ◽  
pp. 1-32
Author(s):  
Katja D Repp ◽  
Dörte Radke ◽  
Till Ittermann ◽  
Martin Albers ◽  
Marcello R P Markus ◽  
...  

Abstract Currently various protocols regarding the site of waist circumference (WC) measurement are in place. This study aimed to analyze the effect of the site of WC measurement on visceral fat (VAT) estimation. WC was obtained at seven anatomical sites in 211 German volunteers (103 males) aged 23-81 using 3-dimensional photonic body scanning (PBS). At one site WC was additionally measured by tape. The quantity of VAT was assessed by magnetic resonance imaging (MRI). Models to estimate VAT based on WC were developed; the precision of the estimation is represented by R2. The influence of the applied method of WC assessment (tape vs. PBS) on the estimations is reported. Results show that the amount of estimated VAT and the precision of VAT estimation were dependent on the site of measurement. VAT was estimated most precisely by WC taken at the level of the lowest rib (WCrib: R²=0.75 females; 0.79 males), the minimum circumference (WCmin: R²=0.75 females; 0.77 males) and at the narrowest part of the torso (WCnar: R²=0.76 females; 0.77 males), and least precisely by WC assessed at the top of iliac crest (WCiliac: R²=0.61 females; 0.60 males). VAT estimates based on WC obtained by PBS were smaller and estimations were slightly less precise compared to estimates based on tape measures. Our results indicate that the method and the site of waist measurement should be considered when estimating VAT based on WC. The implementation of a standardized protocol using either WCrib, WCmin or WCnar could improve the precision of VAT estimation.


2021 ◽  
Vol 14 (3) ◽  
pp. 86-93
Author(s):  
R.A. Romanov ◽  
◽  
A.V. Koryakin ◽  
A.V. Sivkov ◽  
B.Ya. Alekseev ◽  
...  

Introduction. Significant improvement in the quality of visualization of the prostate using magnetic resonance imaging (MRI), as well as the development of technologies for virtual combination of MRI and ultrasound images opens new horizons in the diagnosis of prostate cancer. The introduction of the PI-RADS system has allowed the standardization of MRI findings, and the development of fusion biopsy systems seeks to make diagnostics more accurate and less operator-dependent. Materials and methods. In this literature review, we evaluate the effectiveness of various biopsy approaches and discuss the prospects for targeted biopsies. The search for publications was carried out in the databases PubMed, e-library, Web of Scince et al. For citation, 55 literature sources were selected that met the search criteria for the keywords, «prostate cancer», «biopsy», «MRI», «TRUS», «fusion». Results. Diagnosis of prostate cancer using MRI. Modern technologies for radiological diagnosis of prostate cancer using magnetic resonance imaging (MRI) are based on the standardized PI-RADS protocol, using different modes (T2, diffusion-weighted images and contrast enhancement), which provides the best visualization of tumor-suspicious nodes in the prostate gland, allowing determination of lesion localization and size for subsequent targeted biopsy. Options for performing a prostate biopsy to diagnose prostate cancer. A description of the methods and effectiveness of transrectal and transperineal biopsy under ultrasound guidance is carried out - due to the fact that ultrasound diagnostics of prostate cancer has a rather low sensitivity due to small differences in the ultrasound structure of normal and tumor tissue of the prostate, an extended template biopsy technique was proposed, which involves puncture of the prostate through a special lattice. It also describes the technology of fusion biopsy and also provides literature data comparing the diagnostic accuracy of standard TRUS and fusion prostate biopsy, as well as the importance of transrectal / transperineal access. Questions for further study. Given the desire to reduce the number of biopsies while maintaining or even increasing the accuracy of diagnosing prostate cancer, data from studies investigating the feasibility of combining polyfocal (non-targeted) and targeted (targeted) biopsies are presented. Conclusion. The existing methods of non-targeted biopsy (polyfocal, saturation, template) and targeted (fusion biopsy) have their advantages and disadvantages, which currently do not allow making certain recommendations for their use, but a significant number of authors prefer MRI-as sisted, fusion -biopsy.


Cancers ◽  
2020 ◽  
Vol 12 (12) ◽  
pp. 3523
Author(s):  
Jing Zhao ◽  
Dilyana B. Mangarova ◽  
Julia Brangsch ◽  
Avan Kader ◽  
Bernd Hamm ◽  
...  

Purpose: We aimed to evaluate the correlation between PSMA uptake and magnetic resonance imaging (MRI) PI-RADS of simultaneous [68Ga]Ga-PSMA-11 PET/MRI regarding PI-RADS version 2.0 and 2.1 respectively and compared the difference between these two versions. Materials and Methods: We retrospectively analyzed a total of forty-six patients with biopsy-proven prostate cancer who underwent simultaneous [68Ga]Ga-PSMA-11 PET/MRI. We classified the lesions regarding PI-RADS version 2.0 and 2.1, peripheral zone (PZ), and transitional zone (TZ), respectively. Based on regions of interest (ROI), standardized uptake values maximum (SUVmax), and corresponding lesion-to-background ratios (LBR) of SUVmax of each category, PI-RADS score 1 to 5, were measured. A comparison between PI-RADS version 2.0 and PI-RADS version 2.1 was performed. Results: A total of 215 focal prostate lesions were analyzed, including two subgroups, 125 TZ and 90 PZ. Data are reported as median and interquartile range (IQR). Regarding PI-RADS version 2.1, TZ SUVmax of each category were 1.5 (0.5, 1.9), 1.9 (0.8, 2.3), 3.3 (2.1, 4.6), 4.2 (3.1, 5.7), 7.3 (5.2, 9.7). PZ SUVmax of each category were 1.0 (0.8, 1.6), 2.5 (1.5, 3.2), 3.3 (1.9, 4.5), 4.3 (3.0, 5.4), 7.4 (5.0, 9.3). Regarding the inter-reader agreement of the overall PI-RADS assessment category, the kappa value was 0.723 for version 2.0 and 0.853 for version 2.1. Conclusion: Revisions of PI-RADS version 2.1 results in variations in lesions classification. Lesions with the PI-RADS category of 3, 4, and 5 present relatively higher intraprostatic PSMA uptake, while lesions with the PI-RADS category of 1 and 2 present relatively lower and similar uptake. Version 2.1 has higher inter-reader reproducibility than version 2.0.


Sign in / Sign up

Export Citation Format

Share Document