scholarly journals Numerical Study of a Customized Transtibial Prosthesis Based on an Analytical Design under a Flex-Foot® Variflex® Architecture

2020 ◽  
Vol 10 (12) ◽  
pp. 4275
Author(s):  
Marco Antonio Hernández-Acosta ◽  
Christopher René Torres-San Miguel ◽  
Armando Josue Piña-Díaz ◽  
Juan Carlos Paredes-Rojas ◽  
Luis Antonio Aguilar-Peréz ◽  
...  

This work addresses the design, analysis, and validation of a transtibial custom prosthesis. The methodology consists of the usage of videometry to analyze angular relationships between joints, moments, and reaction forces in the human gait cycle. The customized geometric model of the proposed prosthesis was defined by considering healthy feet for the initial design. The prosthesis model was developed by considering the Flex-Foot® Variflex® architecture on a design basis. By means of the analytical method, the size and material of the final model were calculated. The behavior of the prosthesis was evaluated analytically by a curved elements analysis and the Castigliano theorem, and numerically by the Finite Element Method (FEM). The outcome shows the differences between the analytical and numerical methods for the final prosthesis design, with an error rate no greater than 6.5%.

1998 ◽  
Vol 80 (4) ◽  
pp. 1868-1885 ◽  
Author(s):  
R. Grasso ◽  
L. Bianchi ◽  
F. Lacquaniti

Grasso, R., L. Bianchi, and F. Lacquaniti. Motor patterns for human gait: backward versus forward locomotion. J. Neurophysiol. 80: 1868–1885, 1998. Seven healthy subjects walked forward (FW) and backward (BW) at different freely chosen speeds, while their motion, ground reaction forces, and electromyographic (EMG) activity from lower limb muscles were recorded. We considered the time course of the elevation angles of the thigh, shank, and foot segments in the sagittal plane, the anatomic angles of the hip, knee, and ankle joints, the vertical and longitudinal ground reaction forces, and the rectified EMGs. The elevation angles were the most reproducible variables across trials in each walking direction. After normalizing the time course of each variable over the gait cycle duration, the waveforms of all elevation angles in BW gait were essentially time reversed relative to the corresponding waveforms in FW gait. Moreover, the changes of the thigh, shank, and foot elevation covaried along a plane during the whole gait cycle in both FW and BW directions. Cross-correlation analysis revealed that the phase coupling among these elevation angles is maintained with a simple reversal of the delay on the reversal of walking direction. The extent of FW–BW correspondence also was good for the hip angle, but it was smaller for the knee and ankle angles and for the ground reaction forces. The EMG patterns were drastically different in the two movement directions as was the organization of the muscular synergies measured by cross-correlation analysis. Moreover, at any given speed, the mean EMG activity over the gait cycle was generally higher in BW than in FW gait, suggesting a greater level of energy expenditure in the former task. We argue that conservation of kinematic templates across gait reversal at the expense of a complete reorganization of muscle synergies does not arise from biomechanical constraints but may reflect a behavioral goal achieved by the central networks involved in the control of locomotion.


2016 ◽  
Vol 35 (3) ◽  
pp. 21-28
Author(s):  
Anatoly S. Bobe ◽  
◽  
Dmitry V. Konyshev ◽  
Sergey A. Vorotnikov ◽  
◽  
...  
Keyword(s):  

2011 ◽  
Vol 264-265 ◽  
pp. 24-29 ◽  
Author(s):  
Seyed Mohammad Ebrahimi ◽  
Seyed Ali Asghar Akbari Mousavi ◽  
Mostafa Soltan Bayazidi ◽  
Mohammad Mastoori

Flow forming is one of the cold forming process which is used for hollow symmetrical shapes. In this paper, the forward flow forming process is simulated using the finite element method and its results are compared with the experimental process. The variation of thickness of the sample is examined by the ultrasonic tests for the five locations of the tubes. To simulate the process, the ABAQUS explicit is used. The effects of flow forming variables such as the angle of rollers and rate of feeding of rollers, on the external variables such as internal diameter, thickness of tube and roller forces are considered. The study showed that the roller force and surface defects were reduced with low feeding rate and low rollers attack angles. Moreover, the sample internal diameter increased at low feeding rate and low rollers attack angles. The optimum variables for flow forming process were also obtained.


2017 ◽  
Vol 2017 ◽  
pp. 1-19 ◽  
Author(s):  
Roman Kvasov ◽  
Lev Steinberg

This paper presents the numerical study of Cosserat elastic plate deformation based on the parametric theory of Cosserat plates, recently developed by the authors. The numerical results are obtained using the Finite Element Method used to solve the parametric system of 9 kinematic equations. We discuss the existence and uniqueness of the weak solution and the convergence of the proposed FEM. The Finite Element analysis of clamped Cosserat plates of different shapes under different loads is provided. We present the numerical validation of the proposed FEM by estimating the order of convergence, when comparing the main kinematic variables with an analytical solution. We also consider the numerical analysis of plates with circular holes. We show that the stress concentration factor around the hole is less than the classical value, and smaller holes exhibit less stress concentration as would be expected on the basis of the classical elasticity.


2012 ◽  
Vol 629 ◽  
pp. 44-48
Author(s):  
Young Wook Hwang ◽  
Kwang Sik Kim ◽  
Tae Young Won

In this paper, we report our numerical study on the electrical-optical properties of the organic light emitting diodes (OLEDs) devices with n-doped layer, which is inserted in an effort to reduce the interface barrier between the cathode and the ETL(electron transport layer). In order to anlayze the electrical and optical characteristics such as the transport behavior of carriers, recombination kinetics, and emission property, we undertake the finite element method (FEM) in OLEDs. Our model includes Poisson’s equation, continuity equation to account for behavior of electrons and holes and the exciton continuity/transfer equation to account for recombination of carriers. We employ the multilayer structure that consists of indium tin oxide (ITO); 2, 2’, 7, 7’ –tetrakis (N, N-diphenylamine) - 9, 9’- spirobi-fluorene (S-TAD); 4, 4’- bis (2,2’- diphenylvinyl) - 1,1’- spirobiphenyl (S-DPVBi); tris (8-quinolinolato) aluminium (Alq3); calsium(Ca).


Sensors ◽  
2021 ◽  
Vol 21 (22) ◽  
pp. 7497
Author(s):  
Roy T. Shahar ◽  
Maayan Agmon

Spatio-temporal parameters of human gait, currently measured using different methods, provide valuable information on health. Inertial Measurement Units (IMUs) are one such method of gait analysis, with smartphone IMUs serving as a good substitute for current gold-standard techniques. Here we investigate the concurrent validity of a smartphone placed in a front-facing pocket to perform gait analysis. Sixty community-dwelling healthy adults equipped with a smartphone and an application for gait analysis completed a 2-min walk on a marked path. Concurrent validity was assessed against an APDM mobility lab (APDM Inc.; Portland, OR, USA). Bland–Altman plots and intraclass correlation coefficients (agreement and consistency) for gait speed, cadence, and step length indicate good to excellent agreement (ICC2,1 > 0.8). For right leg stance and swing % of gait cycle and double support % of gait cycle, results were moderate (0.52 < ICC2,1 < 0.62). For left leg stance and swing % of gait cycle left results show poor agreement (ICC2,1 < 0.5). Consistency of results was good to excellent for all tested parameters (ICC3,1 > 0.8). Thus we have a valid and reliable instrument for measuring healthy adults’ spatio-temporal gait parameters in a controlled walking environment.


2020 ◽  
Vol 15 (3) ◽  
pp. 3-14
Author(s):  
Péter Müller ◽  
Ádám Schiffer

Examining a human movement can provide a wealth of information about a patient’s medical condition. The examination process can be used to diagnose abnormal changes (lesions), ability development and monitor the rehabilitation process of people with reduced mobility. There are several approaches to monitor people, among other things with sensors and various imaging and processing devices. In this case a Kinect V2 sensor and a self-developed LabView based application was used, to examine the movement of the lower limbs. The ideal gait pattern was recorded in the RoboGait training machine and the measured data was used to identify the phases of the human gait. During the evaluation, the position of the skeleton model, the associated body joints and angles can be calculated. The pre-recorded ideal and natural gait cycle can be compared.With the self-developed method the pre-recorded ideal and natural gait cycle can be compared and processed for further evaluation. The evaluated measurement data confirm that a reliable and mobile solution for gait analysis has been created.


2013 ◽  
Vol 7 (1) ◽  
pp. 77-83
Author(s):  
J.W. Kim ◽  
J. H. Doh ◽  
S. Fragomeni

This paper discusses the behaviour characteristics of the shaping formation of Single-Chorded Space Truss (SCST) structures by means of cable-tensioning of bottom chords. The innovative technique is fast and economical and issued in many types of space structures. The small-scale test models presented herein consist of uniform pyramids with multi-directional ball type joints which are erected into their final shape by cable-tensioning. Since the joint behaviour is very significant in studying the shaping of SCST structures, basic tests for beam and pyramidal units were performed. The feasibility of the proposed cable-tensioning technique and the reliability of the established geometric model were confirmed by finite element analysis. The proposed cable-tensioning technique indicates that the behaviour characteristic of joints is very important in the shaping formation of SCST structures. More specifically in situations where heavy cranes are inaccessible, the cable-tensioning construction technique has proven to be an easy and reasonable method compared to conventional construction methods that typically include heavy cranes and scaffolding.


Sign in / Sign up

Export Citation Format

Share Document