scholarly journals Optoelectronic Instrumentation and Measurement Strategies for Optical Chemical (Bio)Sensing

2021 ◽  
Vol 11 (17) ◽  
pp. 7849
Author(s):  
Francisco Ferrero Martín ◽  
Marta Valledor Llopis ◽  
Juan C. Campo Rodríguez ◽  
Alberto López Martínez ◽  
Ana Soldado Cabezuelo ◽  
...  

There is a growing interest in the development of sensitive, portable, and low-cost instrumentation for optical chemical (bio)sensing. Such instrumentation can allow real-time decision-making for industry, farmers, and researchers. The combination of optical fiber schemes, luminescence spectroscopy techniques, and new materials for sensor immobilization has allowed the growth of optical sensors. This article focuses on the development of low-cost optoelectronic instrumentation and measurement strategies for optical chemical (bio)sensing. Most of the articles in this field have focused on the chemical sensors themselves, although few have covered the design process for optoelectronic instrumentation. This article tries to fill this gap by presenting designs for real applications, as carried out by the authors. We also offer an introduction to the optical devices and optical measurement techniques used in this field to allow a full understanding of the applications.

Polymers ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 730 ◽  
Author(s):  
Benjamin O. Asamoah ◽  
Emilia Uurasjärvi ◽  
Jukka Räty ◽  
Arto Koistinen ◽  
Matthieu Roussey ◽  
...  

The prevalent nature of micro and nanoplastics (MP/NPs) on environmental pollution and health-related issues has led to the development of various methods, usually based on Fourier-transform infrared (FTIR) and Raman spectroscopies, for their detection. Unfortunately, most of the developed techniques are laboratory-based with little focus on in situ detection of MPs. In this review, we aim to give an up-to-date report on the different optical measurement methods that have been exploited in the screening of MPs isolated from their natural environments, such as water. The progress and the potential of portable optical sensors for field studies of MPs are described, including remote sensing methods. We also propose other optical methods to be considered for the development of potential in situ integrated optical devices for continuous detection of MPs and NPs. Integrated optical solutions are especially necessary for the development of robust portable and in situ optical sensors for the quantitative detection and classification of water-based MPs.


2021 ◽  
Vol 11 (10) ◽  
pp. 4360
Author(s):  
Laura Borgese ◽  
Maria Chiesa ◽  
Ahmad Assi ◽  
Claudio Marchesi ◽  
Anne Wambui Mutahi ◽  
...  

This paper highlights advantages and drawbacks due to the use of portable and low-cost devices for aerosol sampling, showing their performances during an aerosol monitoring campaign with the parallel use of the gravimetric sampling reference method and a cascade impactor. A specific monitoring campaign was held running all instruments in parallel in indoor, confined, and outdoor environments characterized by local emission sources or particulate matter background concentrations. PM2.5 concentrations were used to compare data emerging from the different instruments adopted. Significant underestimation of PM2.5 emerged when comparing data coming from optical sensors with those estimated by the cascade impactor, whose data resulted in being coherent with gravimetric determination, integrated over the same sampling time. A cause–effect relationship between PM2.5 concentrations and specific emission sources was found when observing the daily patterns of all the real-time sampling devices. It emerged that optical devices are useful for detecting concentration trends, the presence of peak values, or changes in the background value, even if with limited accuracy and precision. The comparison with particle size distributions obtained by the cascade impactor data allowed us to define which particle sizes are not detected by different optical devices, evidencing a low representativeness of optical low-cost sensors for health exposure measurements. The correlations among the specific particle size fractions detected by the cascade impactor and their specific emission sources were particularly high for car emissions in a semi-confined garage area.


VASA ◽  
2015 ◽  
Vol 44 (5) ◽  
pp. 355-362 ◽  
Author(s):  
Marie Urban ◽  
Alban Fouasson-Chailloux ◽  
Isabelle Signolet ◽  
Christophe Colas Ribas ◽  
Mathieu Feuilloy ◽  
...  

Abstract. Summary: Background: We aimed at estimating the agreement between the Medicap® (photo-optical) and Radiometer® (electro-chemical) sensors during exercise transcutaneous oxygen pressure (tcpO2) tests. Our hypothesis was that although absolute starting values (tcpO2rest: mean over 2 minutes) might be different, tcpO2-changes over time and the minimal value of the decrease from rest of oxygen pressure (DROPmin) results at exercise shall be concordant between the two systems. Patients and methods: Forty seven patients with arterial claudication (65 + / - 7 years) performed a treadmill test with 5 probes each of the electro-chemical and photo-optical devices simultaneously, one of each system on the chest, on each buttock and on each calf. Results: Seventeen Medicap® probes disconnected during the tests. tcpO2rest and DROPmin values were higher with Medicap® than with Radiometer®, by 13.7 + / - 17.1 mm Hg and 3.4 + / - 11.7 mm Hg, respectively. Despite the differences in absolute starting values, changes over time were similar between the two systems. The concordance between the two systems was approximately 70 % for classification of test results from DROPmin. Conclusions: Photo-optical sensors are promising alternatives to electro-chemical sensors for exercise oximetry, provided that miniaturisation and weight reduction of the new sensors are possible.


2021 ◽  
Vol 1805 (1) ◽  
pp. 012043
Author(s):  
Asnawi ◽  
N A Siddiq ◽  
M S Muntini ◽  
Y H Pramono

2016 ◽  
Vol 30 (09) ◽  
pp. 1650046 ◽  
Author(s):  
S. Zhang ◽  
J. Yin ◽  
H. W. Zhang ◽  
B. S. Chen

Phoxonic crystal (PXC) is a promising artificial periodic material for optomechanical systems and acousto-optical devices. The multi-objective topology optimization of dual phononic and photonic max relative bandgaps in a kind of two-dimensional (2D) PXC is investigated to find the regular pattern of topological configurations. In order to improve the efficiency, a multi-level substructure scheme is proposed to analyze phononic and photonic band structures, which is stable, efficient and less memory-consuming. The efficient and reliable numerical algorithm provides a powerful tool to optimize and design crystal devices. The results show that with the reduction of the relative phononic bandgap (PTBG), the central dielectric scatterer becomes smaller and the dielectric veins of cross-connections between different dielectric scatterers turn into the horizontal and vertical shape gradually. These characteristics can be of great value to the design and synthesis of new materials with different topological configurations for applications of the PXC.


2021 ◽  
pp. 54-59
Author(s):  
Md. Mahidy Hossain ◽  
Nadim Khandaker

In every aspect of Engineering more advanced, efficient and progressive solutions are required. The modern age of science requires innovative minds. The field of environmental engineering is also advancing with modern science and technology innovations. Measuring of methane concentration and flow rate is nothing new, yet a complicated process. The need for more accurate measurement is a necessity in proper operation of bio digesters for methane generation. The traditional process of the measuring methane content in biogas is time consuming yet complicated. The need for development and application of methane measurement techniques is not only limited to biogas but has other monitoring value as well in other health and safety applications in built environments. Winsen Electronics and Hanwei Electronics are two of the leading sensor-manufactures of China who are providing a wide range of gas detecting sensors that are locally available in Bangladesh and yet has not been applied to methane content measurement in biogas operations. In This paper we are reporting on the application of a purpose-built propane, butane detector for methane gas detection within the range of accuracy for it to be applied in methane detection in a biogas stream. This paper, reports on application and calibration of the methane detecting sensor MQ-4 with promising result. Based on the study we postulate that the sensor can be used to detect methane for an on-line monitoring of many environmental, industrial purposes such as bio digesters, integrated waste management facility. The cost of fabrication of the sensor system is only $18 making it a viable sensor with respect to cost for application in Bangladesh.


Nukleonika ◽  
2016 ◽  
Vol 61 (2) ◽  
pp. 207-212 ◽  
Author(s):  
Irina V. Litovko ◽  
Alexy A. Goncharov ◽  
Andrew N. Dobrovolskiy ◽  
Lily V. Naiko ◽  
Irina V. Naiko

Abstract The paper presents new generation plasma optical devices based on the electrostatic plasma lens configuration that opens a novel attractive possibility for effective high-tech practical applications. Original approaches to use of plasma accelerators with closed electron drift and open walls for the creation of a cost-effective low-maintenance plasma lens with positive space charge and possible application for low-cost, low-energy rocket engine are described. The preliminary experimental, theoretical and simulation results are presented. It is noted that the presented plasma devices are attractive for many different applications in the state-of-the-art vacuum-plasma processing.