scholarly journals Severely Damaged Reinforced Concrete Circular Columns Repaired by Turned Steel Rebar and High-Performance Concrete Jacketing with Steel or Polymer Fibers

2018 ◽  
Vol 8 (9) ◽  
pp. 1671 ◽  
Author(s):  
Junqing Xue ◽  
Davide Lavorato ◽  
Alessandro V. Bergami ◽  
Camillo Nuti ◽  
Bruno Briseghella ◽  
...  

A new strategy that repairs severely damaged reinforced concrete (RC) columns after an earthquake is proposed as a simpler and quicker solution with respect to the strategies currently available in the literature. The external concrete parts are removed from the column surface along the whole plastic hinge region to uncover the steel reinforcement. The transverse steel is cut away, and each longitudinal rebar is locally substituted by steel rebar segments connected by welding connections to the original undamaged rebar pieces outside the intervention zone. The new rebar segments have a reduced diameter achieved by turning to ensure plastic deformation only in the plastic hinge, protecting the original rebar and the welding connections. The connection is specifically designed to be effective and simple, and is directly realized on column reinforcement. Finally, the removed concrete is restored by a jacket built with high-performance concrete with steel or polymer fibers. The use of concrete with high volume fraction of polymer fibers to repair the column is investigated for the first time in this paper. This concrete was characterized by compression and flexural tests in the laboratory and its mechanical characteristics were compared with those of the concrete with steel fibers, which are being increasingly used in construction. The repair strategy was applied to two RC columns (1:6 scaled bridge piers), tested by asymmetric cyclic tests. The results show that the column strength, stiffness, and ductility were restored, and the energy dissipation capacity improved. The experimental evidence was investigated by fiber models in OpenSees.

2019 ◽  
Vol 8 (3) ◽  
pp. 7171-7175

This research work has experimentally investigated on the effects of low modulus fibers (PP) used in concrete for the various percentages like 0. 0.5% and 1.0% (by volume fraction) along with different percentage of sugar cane bagasse ash from 0 to 15% replaced in Portland cement (by weight of binding material) for different mixes and tested for the various properties of high-performance concrete (HPC). This experimental test results indicated that the usage of SCBA is restricted up to 10% with 0.5% of PP (Polypropylene) along with 1.5% of superplasticizers produces the higher flexural strength was increased up to 78.30% and compressive strength of concrete was increased up to 25.80% when compared to control (plain) concrete at 28 days. Finally, the usage of low modulus fibre reinforced concrete to act as a corrosion inhibitor agent during the chloride attack than compared to high modulus fibers and reduce the plastic shrinkage due to excellent flexibility in concrete and also increases the life span.


Buildings ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 63
Author(s):  
Anna L. Mina ◽  
Michael F. Petrou ◽  
Konstantinos G. Trezos

The scope of this paper is to investigate the performance of ultra-high performance fiber reinforced concrete (UHPFRC) concrete slabs, under projectile impact. Mixture performance under impact loading was examined using bullets with 7.62 mm diameter and initial velocity 800 m/s. The UHPFRC, used in this study, consists of a combination of steel fibers of two lengths: 6 mm and 13 mm with the same diameter of 0.16 mm. Six composition mixtures were tested, four UHPFRC, one ultra-high performance concrete (UHPC), without steel fibers, and high strength concrete (HSC). Slabs with thicknesses of 15, 30, 50, and 70 mm were produced and subjected to real shotgun fire in the field. Penetration depth, material volume loss, and crater diameter were measured and analyzed. The test results show that the mixture with a combination of 3% 6 mm and 3% of 13 mm length of steel fibers exhibited the best resistance to projectile impact and only the slabs with 15 mm thickness had perforation. Empirical models that predict the depth of penetration were compared with the experimental results. This material can be used as an overlay to buildings or to construct small precast structures.


2021 ◽  
Vol 28 (2) ◽  
pp. 54-72
Author(s):  
Abd-al-Salam Al-Hazragi ◽  
Assim Lateef

This article investigates the behaviour of strengthened concrete columns using jacketing ultra-high-performance fiber reinforced concrete (UHPFRC) and carbon fiber-reinforced polymer (CFRP) under uniaxial loaded. The jacket was connected to the column core using shear connectors and (CFRP) fixed as a strip on the tension zone between the column cores and the jacketing. Seven column samples of square cross-section (120 x120) mm at the midsection with overall length of 1250 mm were cast using normal strength concrete (NSC) and having similar longitudinal and transverse reinforcement. The samples were made and tested under axial load at eccentricity equal to 120 mm up to failure. Test parameters were the thickness of jackets (25 and 35) mm and the width of CFRP (0,8, and 12) cm. Column specimens were tested, one of them was reference without any strengthening, and the other specimens divided into two groups (A, and B), and each group included three specimens based on the parameters. Group (A) has UHPFRC jacket thickness 25 mm and CFRP width (0,8, and 12) cm respectively, and group (B) has UHPFRC jacket thickness 35 mm and CFRP width (0,8, and 12) cm respectively. The outcomes of the article show that increasing the thickness of jacket, and width of CFRP lead to increase in the load carrying capacity about (110.5%,168.4%, and 184.2%) for group A, and (157.9%,226.3%, and 263.2%) for group B compared with the reference column due to delay in the appearance of cracks and their distribution. The mid-height lateral displacement of columns was decreased about (66.6%,42.3%, and 35.9%) for group A, and (46.15%,38.46%, and 32.3%) for group B, also the axial deformation of specimens decreased about (71.7%,60.86%, and 55.86%) for group A, and (65.5%,60.5%, and 53.4) for group B compared with the reference column. The ductility of columns that were strengthened with UHPFRC jacket only was increased about (13.67%,19.66%) for thickness(25,35) mm respectively, because of that UHPFRC jacket was contented on steel fibers, and the percentage decrease of ductility was about (5.1%,and 12%) for group (A), (1%,and 9.4%) for group (B) when bonded CFRP in the tension zone with width (8 ,and 12) cm respectively. The results show improvement in the initial and secant stiffness when, increased the thickness of jacket, and width of CFRP because of increase in the size of columns and improvement in the modulus of elasticity. The toughness increase was about (273.97%,301.55%, and 304.5%) for group A, and (453.69%,511.93%, and 524.28%) for group B compared with the reference column because of increase in the size of specimens and delay the appearance of cracks.


Materials ◽  
2018 ◽  
Vol 12 (1) ◽  
pp. 11 ◽  
Author(s):  
Kaizhi Liu ◽  
Rui Yu ◽  
Zhonghe Shui ◽  
Xiaosheng Li ◽  
Xuan Ling ◽  
...  

In this paper, two kinds of pumice particles with different diameters and water absorption rates are employed to substitute the corresponding size of river sands by volume fraction, and their effects on the hydration characteristics and persistent shrinkage of Ultra-High Performance Concrete (UHPC) are investigated. The obtained experimental results show that adopting a low dosage of 0.6–1.25 mm saturated pumice as the internal curing agent in UHPC can effectively retract the persistent shrinkage deformation of concrete without a decrease of strength. Heat flow calorimetry results demonstrate that the additional water has a retarding effect and promotes the hydration process. X-ray Diffraction (XRD) and Differential Thermal Gravimetry (DTG) are utilized to quantify the Ca(OH)2 content in the hardened paste, which can confirm that the external moisture could accelerate the early cement hydration and secondary hydration of active mineral admixtures. The Ca/Si ratio of C–S–H calculated by the Energy Dispersive Spectrometer (EDS) reveals that the incorporation of wet pumice can transform the composition and structure of hydration products in its effective area.


Fibers ◽  
2019 ◽  
Vol 7 (7) ◽  
pp. 67 ◽  
Author(s):  
Manish Roy ◽  
Corey Hollmann ◽  
Kay Wille

This paper studied the influence of fiber volume fraction ( V f ), fiber orientation, and type of reinforcement bar (rebar) on the uniaxial tensile behavior of rebar-reinforced strain-hardening ultra-high performance concrete (UHPC). It was observed that the tensile strength increased with the increase in V f . When V f was kept constant at 1%, rebar-reinforced UHPC with fibers aligned with the load direction registered the highest strength and that with fibers oriented perpendicular to the load direction recorded the lowest strength. The strength of the composite with random fibers laid in between. Moreover, the strength, as well as the ductility, increased when the normal strength grade 60 rebars embedded in UHPC were replaced with high strength grade 100 rebars with all other conditions remaining unchanged. In addition, this paper discusses the potential of sudden failure of rebar-reinforced strain hardening UHPC and it is suggested that the composite attains a minimum strain of 1% at the peak stress to enable the members to have sufficient ductility.


Author(s):  
Antoine N. Gergess ◽  
Mahfoud Shaikh Al Shabab ◽  
Razane Massouh

High-strength cementitious materials such as high-performance concrete are extensively used for retrofit of reinforced concrete (RC) structures. The effectiveness of these materials is increased when mixed with steel fibers. A commonly used technique for strengthening and repair of RC beams consists of applying high-performance fiber-reinforced concrete jackets around the beam perimeter. This paper investigates the jacketing method for repairing severely damaged RC beams. Four 2 m (6 ft 63/4 in.) long rectangular RC beams, 200 × 300 mm (8 ×12 in.) were initially cast and loaded until failure based on three-point bending tests. The four beams were then repaired by thickening the sides of the damaged RC beams using a commercially available high-strength shrinkage grout with and without steel fibers. Strain and deformation were recorded in the damaged and repaired beams to compare structural performance. It is shown that the flexural strength of the repaired beams is increased and the crack pattern under loading is improved, proving that the proposed repair method can restore the resistance capacity of RC beams despite the degree of damage. A method for repair is proposed and an analytical investigation is also performed to understand the structural behavior of the repaired beams based on different thickening configurations.


Sign in / Sign up

Export Citation Format

Share Document