scholarly journals Analysis on Mechanical Properties of Recycled Aggregate Concrete Members after Exposure to High Temperatures

2019 ◽  
Vol 9 (10) ◽  
pp. 2057 ◽  
Author(s):  
Zongping Chen ◽  
Ji Zhou ◽  
Peihuan Ye ◽  
Ying Liang

In order to study the mechanical properties of recycled aggregate concrete (RAC) specimens after exposure to high temperatures, 120 RAC prism specimens, 57 reinforced recycled aggregate concrete (RRAC) specimens, and 56 steel reinforced recycled aggregate concrete (SRRAC) specimens were designed, involving two varying parameters such as recycled coarse aggregate (RCA) replacement percentage and temperature. The performance degradation of RCA materials, RRAC members, and SRRAC members after exposure to high temperatures was analyzed in depth. The research results show that after exposure to high temperatures the surface color of members may change from cinereous to gray-white. Some cracks may appear on surface of members and the mass of members may be lighter. With the increase of the experiencing temperatures, the bearing capacity (compressive, bending, and shearing) of RAC and its members are reduced, but their ductility and energy dissipation capacity have little effect on the change of high temperature. With the increase of the RCA replacement percentage, the mass loss ratio, ultimate bearing capacity, and peak deformation of each RAC and its members increase slightly, and the displacement ductility and energy dissipation capacity of the RRAC members decrease slightly. With the increase in replacement percentage of RCA, mechanical properties of RAC and their members have little effect after exposure to elevated temperatures, and the fluctuation range is within 20%.

2018 ◽  
Vol 8 (12) ◽  
pp. 2377 ◽  
Author(s):  
Zongping Chen ◽  
Rusheng Yao ◽  
Chenggui Jing ◽  
Fan Ning

The application of recycled aggregate concrete (RAC) has developed rapidly in recent years. But how to evaluate the residual properties of RAC after the fires is more beneficial to the further popularization and application of RAC. This paper presents the residual properties of RAC and steel reinforced recycled aggregate concrete (SRRAC) components after exposure to elevated temperature. A total of 176 specimens (120 rectangular prisms specimens, 24 SRRAC short columns and 32 SRRAC beams) were designed and tested after exposure to elevated temperature. The parameters were considered in the test, including replacement percentage of recycled coarse aggregate (0%, 30%, 50%, 70% and 100%) and exposure to different temperatures (20, 200, 400, 600 and 800 degrees centigrade). According to the test results, heat damage and residual properties of specimens were analyzed in detail, such as surface change, mass loss, bearing capacity degradation, stiffness degradation, ductility and energy dissipation of specimens under the elevated temperature. The results showed that a series of significant physical phenomena occurred on the surface of RAC and SRRAC components after exposure to elevated temperature, such as the color changed from green-grey to gray-white, chapped on the concrete surface after 400 degrees centigrade and the mass loss of concrete is less than 10%. The degradation of mechanical properties degenerated significantly with the increase of temperature, such as the strength of RAC, and compressive capacity, bending capacity, shear capacity and stiffness of SRRAC components, among that, the degradation of the strength of RAC was most obvious, up to 26%. The ductility and energy dissipation of SRRAC components were insignificant affected by the elevated temperature. Mass loss ratio, peak deformation and bearing capacity showed a slight increase trend with the increase of replacement percentage. But the stiffness showed significant fluctuation when replacement percentage was 70% to 100%. And the ductility and energy dissipation showed significant fluctuation when replacement percentage was 30% to 70%.


Author(s):  
Muhammad Rizwan Riaz ◽  
Rashid Hameed ◽  
Usman Akmal ◽  
Asad Ali Gillani ◽  
Muhammad Ilyas

The energy dissipation capacity of concrete is an important aspect for a Reinforced Concrete (RC) structure to be seismically resistant. Various types of concrete incorporating sustainable materials are being developed these days such as recycled aggregate concrete. Determination of energy dissipation capacity of such new types of concrete is of great importance for their application in RC structures which are to be constructed in seismically active areas. In this regard, the experimental study presented in this contribution investigated the energy dissipation capacity of RC beams constructed using recycled aggregate concrete and subjected to three different deflection amplitude levels of reverse cyclic flexural loading. For this purpose, a total of 20 RC beams of cross section 75 x 150 mm and length of 1350 mm were cast using five different concrete compositions and tested. Among five different concrete compositions, one was control concrete containing 100% natural aggregates while the remaining four compositions were of recycled aggregate concrete containing natural and recycled aggregates. Four replacement levels (25%, 50%, 75%, and 100%) of natural aggregates with recycled aggregates were examined. Results indicated that the amplitude level of imposed deflection is an important factor which influenced the value of energy dissipated by RC beams. Further, results showed that RC beam constructed using recycled aggregate concrete containing 25% recycled aggregates exhibited energy dissipation capacity similar to or even better than that of control RC beam containing 100% natural aggregates.


2021 ◽  
Vol 8 ◽  
Author(s):  
Yunchao Tang ◽  
Wanhui Feng ◽  
Zheng Chen ◽  
Yumei Nong ◽  
Minhui Yao ◽  
...  

The utilization of recycled aggregates made from construction wastes and recycled rubber made from waste tires is an effective method to realize the sustainable development. Thus, this study aims to determine the feasibility of using recycled aggregate concrete containing rubber, named rubberized recycled aggregate concrete (RRAC) as a new type of green-building material. The experimental carbon emissions test verified RRAC as a low-carbon material. In addition, the residual mechanical properties of RRAC were investigated under elevated temperatures. After exposure at 200, 400, and 600 C for 60 min, the stress−strain curve, compressive strength, energy absorption capacity, and spalling resistance of RRAC with recycled aggregate replacement ratios of 50 and 100%, rubber contents of 0, 5, 10, and 15% were explored with microstructural analysis. Moreover, empirical models were proposed to describe the effects of heated temperatures and rubber contents on the stress–strain relationship of RRAC. The results indicated that the rubber particles could reduce the spalling of specimens based on the vapor pressure theory. Therefore, this study provided scientific guidance for the design of structures made with RRAC for resisting high temperatures.


2019 ◽  
Vol 9 (21) ◽  
pp. 4723 ◽  
Author(s):  
Sun ◽  
Guo ◽  
Liu

Experiments were performed on four specimens of steel frames with infilled recycled aggregate concrete shear walls (SFIRACSWs), one specimen of infilled ordinary concrete wall, and one pure-steel frame were conducted under horizontal low cyclic loading. The influence of the composite forms of steel frames and RACSWs (namely, infilled cast-in-place and infilled prefabricated) on the failure modes, transfer mechanisms of lateral force, bearing capacity, and ductility of SFIRACSWs is discussed, and the concrete type and connecting stiffness of beam–column joints (BCJs) are also considered. Test results showed that infilled RACSWs can increase the bearing capacity and lateral stiffness of SFIRACSWs. The connecting stiffness of BCJs slightly influences the seismic behavior of SFIRACSWs. In the infilled cast-in-place RACSWs, the wall cracks mainly extended along the diagonal direction. The bearing capacity was 2.4 times higher than in the pure steel frame, the initial stiffness was 4.3 times higher, and the displacement ductility factors were 2.44–2.69 times higher. In the infilled prefabricated RACSWs, the wall cracks mainly extended along the connection between the embedded T-shape connectors and walls before finally connecting along the horizontal direction. Moreover, shear failure occurred in the specimens. The bearing capacity was 1.44 times higher than that of the pure steel frame, the initial stiffness was 2.8 times higher, and the displacement ductility factors were 3.32–3.40 times higher. The degradation coefficients of the bearing capacity were more than 0.85, indicating that the specimens demonstrated a high safety reserve.


Materials ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2323
Author(s):  
Yubing Du ◽  
Zhiqing Zhao ◽  
Qiang Xiao ◽  
Feiting Shi ◽  
Jianming Yang ◽  
...  

To explore the basic mechanical properties and size effects of recycled aggregate concrete (RAC) with different substitution ratios of coarse recycled concrete aggregates (CRCAs) to replace natural coarse aggregates (NCA), the failure modes and mechanical parameters of RAC under different loading conditions including compression, splitting tensile resistance and direct shear were compared and analyzed. The conclusions drawn are as follows: the failure mechanisms of concrete with different substitution ratios of CRCAs are similar; with the increase in substitution ratio, the peak compressive stress and peak tensile stress of RAC decrease gradually, the splitting limit displacement decreases, and the splitting tensile modulus slightly increases; with the increase in the concrete cube’s side length, the peak compressive stress of RAC declines gradually, but the integrity after compression is gradually improved; and the increase in the substitution ratio of the recycled aggregate reduces the impact of the size effect on the peak compressive stress of RAC. Furthermore, an influence equation of the coupling effect of the substitution ratio and size effect on the peak compressive stress of RAC was quantitatively established. The research results are of great significance for the engineering application of RAC and the strength selection of RAC structure design.


2021 ◽  
pp. 136943322110179
Author(s):  
DongTao Xia ◽  
ShaoJun Xie ◽  
Min Fu ◽  
Feng Zhu

Fiber reinforced recycled aggregate concrete has become a new type of green concrete material. The maximum particle size of coarse aggregates and steel fiber contents affect the mechanical properties and impact resistance of recycled aggregate concrete. However, such studies are rare in literature. The present paper shortens the gap through experimental study. A total of 144 specimens of 12 kinds of concrete mixtures were tested, which adopted different steel fiber volume admixtures (0%, 0.8%, 1.0%, 1.2%) and recycled coarse aggregates in different maximum particle sizes (9.5, 19, 31.5 mm) replacing 30% natural coarse aggregate. The compressive strength, splitting tensile strength, and impact resistance of the 12 concrete mixtures were tested. The results showed that the compressive strength, splitting tensile strength, and impact resistance of recycled aggregate concrete increased first and then decreased with the increase of the maximum particle size. The recycled aggregate concrete with the maximum particle size of 19 mm had the highest mechanical properties and impact resistance. Besides, with the increase of steel fiber content, the compressive strength, splitting tensile strength, and impact resistance of recycled aggregate concrete showed an increasing trend. Considering a large amount of experimental data and the coupling effect of steel fiber contents and the maximum particle size of coarse aggregates, the Weibull distribution function was introduced to analyze the impact test results and predict the number of resistance to impact under different failure probabilities. The results showed that the number of blows of the recycled aggregate concrete followed a two-parameter Weibull distribution, and the estimated value of the number of resistance to impact for failure increased with the increase of the failure probability.


2013 ◽  
Vol 438-439 ◽  
pp. 749-755 ◽  
Author(s):  
Tong Hao ◽  
Dong Li

By the experimental studying on the basic mechanical properties of recycled concrete hollow block masonry, the compressive and shear behavior of recycled aggregate concrete hollow block masonry under different mortar strength were analyzed. Research indicated that the compressive and shear behavior of recycled aggregate concrete hollow block masonry was similar to that of ordinary concrete hollow block masonry. The normal formula was recommended to calculate the compressive strength of the masonry. The shear strength of the masonry was affected by the mortar strength. The shear strength calculation formula of recycled concrete hollow block masonry was proposed according to the formula of masonry design code. The calculating results were in good agreement with the test results.


Sign in / Sign up

Export Citation Format

Share Document