scholarly journals An IoT-Based Non-Invasive Glucose Level Monitoring System Using Raspberry Pi

2019 ◽  
Vol 9 (15) ◽  
pp. 3046 ◽  
Author(s):  
Antonio Alarcón-Paredes ◽  
Victor Francisco-García ◽  
Iris P. Guzmán-Guzmán ◽  
Jessica Cantillo-Negrete ◽  
René E. Cuevas-Valencia ◽  
...  

Patients diagnosed with diabetes mellitus must monitor their blood glucose levels in order to control the glycaemia. Consequently, they must perform a capillary test at least three times per day and, besides that, a laboratory test once or twice per month. These standard methods pose difficulty for patients since they need to prick their finger in order to determine the glucose concentration, yielding discomfort and distress. In this paper, an Internet of Things (IoT)-based framework for non-invasive blood glucose monitoring is described. The system is based on Raspberry Pi Zero (RPi) energised with a power bank, using a visible laser beam and a Raspberry Pi Camera, all implemented in a glove. Data for the non-invasive monitoring is acquired by the RPi Zero taking a set of pictures of the user fingertip and computing their histograms. Generated data is processed by an artificial neural network (ANN) implemented on a Flask microservice using the Tensorflow libraries. In this paper, all measurements were performed in vivo and the obtained data was validated against laboratory blood tests by means of the mean absolute error (10.37%) and Clarke grid error (90.32% in zone A). Estimated glucose values can be harvested by an end device such as a smartphone for monitoring purposes.

Sensors ◽  
2021 ◽  
Vol 21 (20) ◽  
pp. 6820
Author(s):  
Bushra Alsunaidi ◽  
Murad Althobaiti ◽  
Mahbubunnabi Tamal ◽  
Waleed Albaker ◽  
Ibraheem Al-Naib

The prevalence of diabetes is increasing globally. More than 690 million cases of diabetes are expected worldwide by 2045. Continuous blood glucose monitoring is essential to control the disease and avoid long-term complications. Diabetics suffer on a daily basis with the traditional glucose monitors currently in use, which are invasive, painful, and cost-intensive. Therefore, the demand for non-invasive, painless, economical, and reliable approaches to monitor glucose levels is increasing. Since the last decades, many glucose sensing technologies have been developed. Researchers and scientists have been working on the enhancement of these technologies to achieve better results. This paper provides an updated review of some of the pioneering non-invasive optical techniques for monitoring blood glucose levels that have been proposed in the last six years, including a summary of state-of-the-art error analysis and validation techniques.


Electronics ◽  
2019 ◽  
Vol 8 (6) ◽  
pp. 662 ◽  
Author(s):  
Louis WY Liu ◽  
Abhishek Kandwal ◽  
Qingsha Cheng ◽  
Hongjian Shi ◽  
Igbe Tobore ◽  
...  

Non-invasive blood glucose monitoring at microwave frequencies is generally thought to be unreliable in terms of reproducibility of measurements. The failure to reproduce a blood glucose measurement from one experiment to another is in major part due to the unwanted interaction of leaky waves between the ambient environment and the blood glucose measuring device. In this work, we have overcome this problem by simply eliminating the leaky modes through the use of surface electromagnetic waves from a curved Goubau line. In the proposed methodology, a fixed volume of blood-filled skin tissue was first formed by vacuum suction and partially wound with a curved Goubau line which was coated with a 3 mm thick layer of gelatin/glycerin composite. Blood glucose levels were non-invasively determined using a network analyzer. At 4.5 GHz, a near-linear correlation exists between the measured S12 parameters and the blood glucose levels. The measured correlation was highly reproducible and consistent with the measurements obtained using the conventional invasive lancing approach. The findings of this work suggest the feasibility of non-invasive detection of left and right imbalances in the body.


2016 ◽  
Vol 19 (5) ◽  
pp. 397-405 ◽  
Author(s):  
Alina Yur'evna Babenko ◽  
Yulia Alexeevna Kononova ◽  
Alexandr Ivanovich Tsiberkin ◽  
Michail Konstantinovich Khodzitsky ◽  
Elena Nilkolaevna Grineva

Improved prognoses of patients with type 2 diabetes are primarily determined by the extent of blood glucose control (correction of both hyper- and hypoglycemia and normalization of blood glucose levels). The proper identification and timely correction of abnormal blood glucose levels require frequent blood glucose monitoring by the patient. Currently used methods for the self-monitoring of blood glucose have significant drawbacks that limit their use. The most significant problems with these methods include insufficient accuracy, invasiveness and high cost, leading to noncompliance and difficult assessment of disease status. Such factors underscore the need for a noninvasive, cost-effective and highly accurate method to measure blood glucose levels. There are several different approaches for the noninvasive measurement of blood glucose levels, including optical analysis, ultrasound and bioimpedance. The concept of a noninvasive glucometer was launched more than 30 years ago. Nevertheless, most noninvasive technologies are still in early stages of development and are not used in clinical practice. This review describers the most promising developments in this area.


Author(s):  
Aymen Owais Ghauri ◽  
Saeed Ahmad ◽  
Tayyeba Rehman

AbstractBackgroundDiabetes is the one of the leading cause of morbidity and mortality. Traditionally phytotherapy is widely being used for diabetes treatment and highly valued. Citrus colocynthis has known anti-diabetic potential. However, anti-diabetic potential of hydro-ethanolic extract of C. colocynthis pulpy flesh with seeds is not reported yet.MethodsThe extract of C. colocynthis pulpy flesh with seeds was done by maceration method using 70% ethanol. To evaluate anti-diabetic and antioxidant potential of the seeded fruit in vitro, α-glucosidase and DPPH inhibition assays was done, respectively. In vivo study used streptozotocin (STZ) induced diabetes model of rats. Rats were randomized in five groups i. e. normal control, negative control, standard control, C. colocynthis 150 and 300 mg/kg. STZ was administered to all groups except normal control. After wards, plant extract and glibenclamide is continued for 14 days. Blood samples were collected from rat tail vein daily and from Cardiac puncture at the end of study. The blood glucose levels were monitored daily by using one-touch blood glucose monitoring system. The blood glucose level was monitored on 0, 1st, 5th, 8th, 11th, and 14th day of induction.ResultsHydro-ethanolic extract of C. colocynthis pulpy flesh with seeds was able to decolorize DPPH and therefore possess antioxidant potential, continuous administration for 14 days showed a marked decrease in serum glucose levels (p 0.01) it is found to be somewhat less effective as glibenclamide (standard control) (p 0.001). A time-dependent decrease in blood glucose levels was observed (351.3 ± 4 to 258 m/kg).ConclusionHydro-ethanolic extract of C. colocynthis pulpy flesh with seeds lowered the serum triglyceride and cholesterol levels in diabetic rats significantly as compared to negative control. The hypoglycemic effect of hydro-ethanolic extract of C. colocynthis pulpy flesh with seeds is may be due to α-glucosidase inhibition potential.


2021 ◽  
Author(s):  
Matthes Kenning ◽  
Anselm Puchert ◽  
Eckhard Salzsieder

BACKGROUND Maintaining normal blood glucose levels in diabetes therapy is fundamentally linked to precise and accurate blood glucose measurements. In the light of interfering quantities like various substances or hematocrit, these aspects are of utmost clinical importance within a standardized validation of blood glucose monitors for personal use as well as a continuous quality assessment. OBJECTIVE Continuous and independent quality assurance of aspects affecting a blood glucose monitoring system’s performance. METHODS The influence of the hematocrit on the performance of three blood glucose monitors was assessed in accordance with ISO 15197 and sponsor’s requirements. RESULTS Only one device showed acceptable deviations of ≤ 10 mg/dL / 10 % to the reference device across the entire range. The other devices showed minor to clinically relevant interferences, particularly in response to higher hematocrit values. CONCLUSIONS Suitable BGM systems should be selected carefully by health care professionals and patients, especially with medical conditions known to interfere with blood glucose measurements.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Yizhou Zou ◽  
Wanli Wang ◽  
Dongmei Zheng ◽  
Xu Hou

Abstract Background There are many continuous blood glucose monitoring (CGM) data-based indicators, and most of these focus on a single characteristic of abnormal blood glucose. An ideal index that integrates and evaluates multiple characteristics of blood glucose has not yet been established. Methods In this study, we proposed the glycemic deviation index (GDI) as a novel integrating characteristic, which mainly incorporates the assessment of the glycemic numerical value and variability. To verify its effectiveness, GDI was applied to the simulated 24 h glycemic profiles and the CGM data of type 2 diabetes (T2D) patients (n = 30). Results Evaluation of the GDI of the 24 h simulated glycemic profiles showed that the occurrence of hypoglycemia was numerically the same as hyperglycemia in increasing GDI. Meanwhile, glycemic variability was added as an independent factor. One-way ANOVA results showed that the application of GDI showed statistically significant differences in clinical glycemic parameters, average glycemic parameters, and glycemic variability parameters among the T2D groups with different glycemic levels. Conclusions In conclusion, GDI integrates the characteristics of the numerical value and the variability in blood glucose levels and may be beneficial for the glycemic management of diabetic patients undergoing CGM treatment.


Author(s):  
Nur Hasanah Ahniar

We present a medical records system and reminders to patients of the measurement results of non-invasive blood glucose levels. Measuring blood glucose levels is vital in avoiding potential adverse health effects like diabetes. Diabetes is a chronic metabolic disorder caused by a decrease in the pancreas to produce insulin. Generally, measuring blood glucose levels using the conventional method is injure the patient's finger. Currently, the non-invasive method was famous as one of the detections of blood glucose by applying the physical properties of laser absorption. In this paper, we use the photodiode as a detector, the LED as a sensor, and a signal conditioning circuit. The results showed that non-invasive glucose monitoring has the potential to measure glucose levels with sensitivity and linearity of 3.21 mg/dL and 98%, respectively. As a result of measuring the blood glucose levels of the subject was displayed on the LCD module was designed. We designed a simple application and medical record using Blynk applications and GUI MATLAB for recording the measurement results of blood glucose level. In the future, applications that have been developed can be used by doctors for monitoring the measurement of the blood glucose level and provide information to patients by mobile applications, sending an email or message the measurement results, the decision of a disease or not, and reminds the re-measurement time.


2006 ◽  
Vol 15 (4) ◽  
pp. 370-377 ◽  
Author(s):  
Daleen Aragon

• Background Tight glycemic control is important in critically ill patients and involves insulin infusions and monitoring of blood glucose levels. Hourly measurements of blood glucose levels and adjustments of intravenous insulin doses require additional work by nurses. • Objectives To evaluate the nursing work incurred with and nursing perceptions about tight glycemic control and blood glucose monitoring. • Methods A variety of intensive care units were studied. Surveys were used to gain information about nurses’ perceptions. Time-in-motion observations were used to determine the time taken to measure blood glucose levels and adjust insulin doses. • Results Nurses thought that tight glycemic control was important and that the work associated with it was substantial. Nurses thought that easier and automated forms of blood glucose monitoring are needed. They preferred using an arterial catheter to obtain blood samples to avoid excessive finger sticks. The total number of blood glucose measurements was 77 954. The mean time taken for hourly blood glucose monitoring and adjustment of insulin doses was 4.72 minutes. The estimated costs of time spent on glycemic control during a 1-year period were $182 488 for nurses’ salaries and $58 500 for supplies. • Conclusions Although most nurses endorse tight glycemic control, the work associated with it is burdensome and costly. Because up to 2 hours might be required for tight glycemic control for a single patient in a 24-hour period, the costs in time and money are high. Easier clinical methods for monitoring blood glucose levels are needed.


2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Jan Vrba ◽  
Jakub Karch ◽  
David Vrba

A suitability of two different liquid phantoms of blood-glucose solutions as phantoms for development of microwave sensors for noninvasive blood glucose monitoring is compared. The two phantoms are physiological saline-glucose and pig blood-glucose solutions. For this purpose a simple microwave sensor is developed for in vitro monitoring of blood glucose levels. The sensor consists of a microstrip antenna and of a small rectangular container on the top of the antenna. The container is filled with one of the liquid phantoms. Both phantoms with different glucose concentrations ranging from 0 to 500 mg/dL are considered. Dependence of sensor’s resonant frequency on glucose concentration of LUTs is both estimated by aid of numerical simulations and measured. The results are discussed and compared with some results reported in the literature.


The fluid and glucose chapter focuses primarily on unwell newborns who need early blood glucose monitoring for hypoglycemia and immediate stabilization with intravenous dextrose solution. But infants can be at risk for low blood glucose for many reasons, and they too need specific attention and care, even when they are not symptomatic. Oral doses of dextrose gel may help to raise blood glucose levels, which also depend on whether an infant cannot feed or should not be fed (for any reason) and response to supplementation or managed oral feeding. Guidance includes glucose thresholds to aim for, determined by postnatal age, and testing intervals to expedite the normalization of blood glucose values. How to assess, measure, and anticipate fluid requirements in at-risk infants is explained in detail, and risks for hypoglycaemia, dehydration, and overhydration are considered. Two case scenarios examine different hypoglycaemia risks.