scholarly journals Differences in Dynamics of Lung Computed Tomography Patterns between Survivors and Deceased Adult Patients with COVID-19

Diagnostics ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 1937
Author(s):  
Gevorg B. Akopyan ◽  
Alexander B. Berdalin ◽  
Ilya L. Gubskiy ◽  
and Vladimir G. Lelyuk

This study’s aim was to investigate CT (computed tomography) pattern dynamics differences within surviving and deceased adult patients with COVID-19, revealing new prognostic factors and reproducing already known data with our patients’ cohort: 635 hospitalized patients (55.3% of them were men, 44.7%—women), of which 87.3% had a positive result of RT-PCR (reverse transcription-polymerase chain reaction) at admission. The number of deaths was 53 people (69.8% of them were men and 30.2% were women). In total, more than 1500 CT examinations were performed on patients, using a GE Optima CT 660 computed tomography (General Electric Healthcare, USA). The study was performed at hospital admission, the frequency of repetitive scans further varied based on clinical need. The interpretation of the imaging data was carried out by 11 radiologists with filling in individual registration cards that take into account the scale of the lesion, the location, contours, and shape of the foci, the dominating types of changes, as well as the presence of additional findings and the dynamics of the process—a total of 45 parameters. Statistical analysis was performed using the software packages SPSS Statistics version 23.0 (IBM, Armonk, NY, USA) and R software version 3.3.2. For comparisons in pattern dynamics across hospitalization we used repeated measures general linear model with outcome and disease phase as factors. The crazy paving pattern, which is more common and has a greater contribution to the overall CT picture in different phases of the disease in deceased patients, has isolated prognostic significance and is probably a reflection of faster dynamics of the process with a long phase of progression of pulmonary parenchyma damage with an identical trend of changes in the scale of the lesion (as recovered) in this group of patients. Already known data on typical pulmonological CT manifestations of infection, frequency of occurrence, and the prognostic significance of the scale of the lesion were reproduced, new differences in the dynamics of the process between recovered and deceased adult patients were also found that may have prognostic significance and can be reflected in clinical practice.

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
J Jouan ◽  
I Masari ◽  
V Bliah ◽  
G Soulat ◽  
D Craiem ◽  
...  

Abstract Introduction In order to improve knowledge of the tricuspid valve (TV) function and its coupling with the right atrio-ventricular junction (RAVJ) and right ventricle (RV), new four-dimensional high-definition imagery methods are mandatory (3D+t). Purpose Using an innovative reconstruction method based on multiphase cardiac computed tomography imaging (4D-MCCTI), we finely analyzed the morphological & dynamical features of tricuspid annulus (TA) and RAVJ components in order to assess new functional parameters of TV and RV functions. Methods Volume imaging data sets through time were obtained from 4D-MCCTI of 30 subjects (sex ratio 1, mean age 57±11y.) with no rhythm, valvular or ventricular abnormalities on echocardiography and implemented in a custom software for 3D semi-automated delineation of 18 points around TA perimeter. Coordinates of these points in each of the 10 time-phases within an RR interval were used to calculate specific geometrical features of TA such as 3D/2D areas, perimeters, 360°-diameters and vertical deformation. Subsequently, RV and Right Atrium (RA) inner contours were also delineated (Figure). Results TA shape was elliptical in horizontal projection with a mean eccentricity index (EcI) of 0.58±0.12; and saddle-shapped in vertical projection with a horn nearby the antero-septal commissure. This feature remained throughout the cardiac cycle but TA was more planar (minimal TA-height: 4.47±1.04 mm) and circular (minimal EcI=0.44±0.14) in mid-diastole when TA-3Darea and TA-3Dperimeter reached a maximum of 6.98±1.21 cm2/m2 and 7.41±0.91 cm, respectively. Correlation between TA-3Darea, TA-2Darea and latero-septal diameter (LSD) were R2=0.99 and R2=0.73, respectively. LSD was minimal in early-systole (18.83±3.04 mm/m2) and maximal in mid-diastole (20.04±3.05 mm/m2). Correlation of TA-3Darea with RV and RA cross-sectional areas were R2=0.82 and R2=0.71, respectively. Conversely, there was no significant correlation between TA, RV and RA concentric contractions. Conclusions Our method for 4D-MTCCI analysis has allowed confirming the shape and dynamics function of RAVJ throughout the cardiac cycle in healthy subjects, and giving new reference parameters for TV and RV evaluation. Software multiplanar view of TA Funding Acknowledgement Type of funding source: None


Hepatology ◽  
1996 ◽  
Vol 24 (1) ◽  
pp. 10-13 ◽  
Author(s):  
H Yotsuyanagi ◽  
K Koike ◽  
K Yasuda ◽  
K Moriya ◽  
Y Shintani ◽  
...  

2013 ◽  
Vol 2 (2) ◽  
pp. 50-54
Author(s):  
Ashok Sethi ◽  
Thomas Kaus ◽  
Naresh Sharma ◽  
Peter Sochor

Safe clinical practice in implant dentistry requires an accurate investigation of the availability of bone for implant placement and the avoidance of critical anatomical structures. Modern imaging techniques using computed tomography (CT) and cone beam computed tomography (CBCT) provide the clinician with the required information. The imaging thus obtained provides accurate representation of the height, width and length of the available bone.1 In addition, whenever adequate radiation dose is used, accurate information about the bone density in Hounsfield units can be obtained. Important spatial information regarding the orientation of the ridges and the relationship to the proposed prosthetic reconstruction can be obtained with the aid of radiopaque templates during the acquisition of CT scan data. Modern software also provides the facility to decide interactively upon the positioning of the implants and is able to relate this to a stereolithographic model constructed from the imaging data. A surgical guide for the accurate positioning of the implants can be constructed. The construction of screw retained prostheses is fraught with difficulties regarding the accuracy of the construction. Accurate fit of the prosthesis is difficult to obtain due to the inherent errors in impression taking, component discrepancies, investing and casting inaccuracies.2,3 CAD/CAM technology eliminates the inaccuracies involved with the investing and casting of superstructures. Clinical Case This case describes the management of an 84 year old female patient, who had recently lost her remaining mandibular anterior teeth. This resulted in the patient's inability to wear conventional dentures in the mandible.


PLoS ONE ◽  
2013 ◽  
Vol 8 (8) ◽  
pp. e70812 ◽  
Author(s):  
Era L. Pogosova-Agadjanyan ◽  
Kenneth J. Kopecky ◽  
Fabiana Ostronoff ◽  
Frederick R. Appelbaum ◽  
John Godwin ◽  
...  

2022 ◽  
Author(s):  
M. El Mansouri ◽  
M. Talbi ◽  
A. Choukri ◽  
O. Nhila ◽  
M. Aabid

In Morocco, the radiation doses received by adult patients are increasing due to the number of CT examinations performed and the larger number of computed tomography (CT) scanners installed. The aim of this study was to evaluate the radiation doses received by patients for the most common adult CT examinations in order to establish local diagnostic reference levels (DRLs). Data from 1016 adult patients were collected during 3 months from four Moroccan hospitals. Dose length product (DLP) and volumetric computed tomography dose index (CTDIvol) were evaluated by determining the 75th percentile as diagnostic reference levels for the most common examinations including head, chest and abdomen. The DRL for each examination was compared with other studies. The established DRLs in Morocco in terms of CTDIvol were 57.4, 12.3 and 10.9 for CT examinations of the head, chest, abdomen, respectively. For DLP, they were 1020, 632 and 714, respectively. These established DRLs for CTDIvol were almost similar to the UK DRLs at all examinations, higher than the Egyptian DRLs and lower than the Japanese DRLs at the head CT examination, lower than the DRLs from Egypt and Japan at the CT abdomen examination. In terms of DLP, the DRLs were higher than those of the British studies, lower than those of the Egyptian and Japanese studies at the head CT examination were higher at chest CT and lower at abdominal CT than those of all selected studies. The higher level of established DRLs in our study demonstrates the requirement of an optimization process while keeping a good image quality for a reliable diagnosis.


Sign in / Sign up

Export Citation Format

Share Document