scholarly journals Correlation between Commercial Anti-RBD IgG Titer and Neutralization Titer against SARS-CoV-2 Beta Variant

Diagnostics ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 2216
Author(s):  
Rosana Wing-Shan Poon ◽  
Lu Lu ◽  
Carol Ho-Yan Fong ◽  
Tak-Chuen Ip ◽  
Lin-Lei Chen ◽  
...  

Objectives: The emergence of SARS-CoV-2 variants of concern (VOCs) have diminished the effectiveness of vaccines and are associated with a rebound in the number of COVID-19 cases globally. These variants contain mutations at the spike (S) protein receptor binding site (RBD), which affect antibody binding. Current commercially available antibody assays were developed before the VOCs emerged. It is unclear whether the levels of these commercially available antibody assays can predict the neutralizing antibody titers against the VOCs. In this study, we sought to determine the correlation between the binding antibody concentration and microneutralization antibody titer against the beta variant. Methods: This study included 58 COVID-19 patients. The concentrations of IgG against the SARS-CoV-2 spike protein RBD and nucleocapsid (N) protein were measured using the Abbott SARS-CoV-2 IgG II Quant assay and the SARS-CoV-2 IgG assay, respectively. The neutralization antibody titer against the wild type lineage A SARS-CoV-2 and against the beta variant (B.1.351) was determined using a conventional live virus neutralization test. Results: The geometric mean MN titer (GMT) against the beta variant was significantly lower than that against the wild type lineage A virus (5.6 vs. 47.3, P<0.0001). The anti-RBD IgG had a better correlation with the neutralizing antibody titer than that of the anti-N IgG assay against the wild type lineage A virus (Spearman rho, 0.5901 vs. 0.3827). However, the correlation between the anti-RBD or the anti-N IgG and the MN titer against the beta variant was poor. Conclusions: Currently available commercial antibody assays may not predict the level of neutralizing antibodies against the variants. A new generation of antibody tests specific for variants are required.

2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Nanda Kishore Routhu ◽  
Narayanaiah Cheedarla ◽  
Venkata Satish Bollimpelli ◽  
Sailaja Gangadhara ◽  
Venkata Viswanadh Edara ◽  
...  

AbstractThere is a great need for the development of vaccines that induce potent and long-lasting protective immunity against SARS-CoV-2. Multimeric display of the antigen combined with potent adjuvant can enhance the potency and longevity of the antibody response. The receptor binding domain (RBD) of the spike protein is a primary target of neutralizing antibodies. Here, we developed a trimeric form of the RBD and show that it induces a potent neutralizing antibody response against live virus with diverse effector functions and provides protection against SARS-CoV-2 challenge in mice and rhesus macaques. The trimeric form induces higher neutralizing antibody titer compared to monomer with as low as 1μg antigen dose. In mice, adjuvanting the protein with a TLR7/8 agonist formulation alum-3M-052 induces 100-fold higher neutralizing antibody titer and superior protection from infection compared to alum. SARS-CoV-2 infection causes significant loss of innate cells and pathology in the lung, and vaccination protects from changes in innate cells and lung pathology. These results demonstrate RBD trimer protein as a suitable candidate for vaccine against SARS-CoV-2.


2021 ◽  
Author(s):  
Lu Lu ◽  
Bobo Mok ◽  
Linlei Chen ◽  
Jacky Chan ◽  
Owen Tsang ◽  
...  

Background The SARS-CoV-2 Omicron variant, designated as a Variant of Concern(VOC) by the World Health Organization, carries numerous spike protein mutations which have been found to evade neutralizing antibodies elicited by COVID-19 vaccines. The susceptibility of Omicron variant by vaccine-induced neutralizing antibodies are urgently needed for risk assessment. Methods Omicron variant strains HKU691 and HKU344-R346K were isolated from patients using TMPRSS2-overexpressing VeroE6 cells. Whole genome sequence was determined using nanopore sequencing. Neutralization susceptibility of ancestral lineage A virus and the Omicron, Delta and Beta variants to sera from 25 BNT162b2 and 25 Coronavac vaccine recipients was determined using a live virus microneutralization assay. Results The Omicron variant strain HKU344-R346K has an additional spike R346K mutation, which is present in 8.5% of strains in GISAID database. Only 20% and 24% of BNT162b2 recipients had detectable neutralizing antibody against the Omicron variant HKU691 and HKU344-R346K, respectively, while none of the Coronavac recipients had detectable neutralizing antibody titer against either Omicron isolates. For BNT162b2 recipients, the geometric mean neutralization antibody titers(GMT) of the Omicron variant isolates(5.43 and 6.42) were 35.7-39.9-fold lower than that of the ancestral virus(229.4), and the GMT of both omicron isolates were significantly lower than those of the beta and delta variants. There was no significant difference in the GMT between HKU691 and HKU344-R346K. Conclusions Omicron variant escapes neutralizing antibodies elicited by BNT162b2 or CoronaVac. The additional R346K mutation did not affect the neutralization susceptibility. Our data suggest that the Omicron variant may be associated with lower COVID-19 vaccine effectiveness.


Viruses ◽  
2021 ◽  
Vol 13 (11) ◽  
pp. 2270
Author(s):  
Gloria Griffante ◽  
Shikha Chandel ◽  
Daniela Ferrante ◽  
Valeria Caneparo ◽  
Daniela Capello ◽  
...  

Longitudinal mapping of antibody-based SARS-CoV-2 immunity is critical for public health control of the pandemic and vaccine development. We performed a longitudinal analysis of the antibody-based immune response in a cohort of 100 COVID-19 individuals who were infected during the first wave of infection in northern Italy. The SARS-CoV-2 humoral response was tested using the COVID-SeroIndex, Kantaro Quantitative SARS-CoV-2 IgG Antibody RUO Kit (R&D Systems, Bio-Techne, Minneapolis, USA) and pseudotype-based neutralizing antibody assay. Using sequential serum samples collected from 100 COVID-19 recovered individuals from northern Italy—mostly with mild disease—at 2 and 10 months after their first positive PCR test, we show that 93% of them seroconverted at 2 months, with a geometric mean (GeoMean) half-maximal neutralization titer (NT50) of 387.9. Among the 35 unvaccinated subjects retested at 10 months, 7 resulted seronegative, with an 80% drop in seropositivity, while 28 showed decreased anti-receptor binding domain (RBD) and anti-spike (S) IgG titers, with a GeoMean NT50 neutralization titer dropping to 163.5. As an NT50 > 100 is known to confer protection from SARS-CoV-2 re-infection, our data show that the neutralizing activity elicited by the natural infection has lasted for at least 10 months in a large fraction of subjects.


2021 ◽  
Author(s):  
Simon Jochum ◽  
Imke Kirste ◽  
Sayuri Hortsch ◽  
Veit Peter Grunert ◽  
Holly Legault ◽  
...  

Background The ability to quantify an immune response after vaccination against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential. This study assessed the clinical utility of the quantitative Roche Elecsys® Anti-SARS-CoV-2 S assay (ACOV2S) using samples from the 2019-nCoV vaccine (mRNA-1273) phase 1 trial (NCT04283461). Methods Samples from 30 healthy participants, aged 18-55 years, who received two injections with mRNA-1273 at a dose of 25 μg (n=15) or 100 μg (n=15), were collected at Days 1 (first vaccination), 15, 29 (second vaccination), 43 and 57. ACOV2S results (shown in U/mL - equivalent to BAU/mL per the first WHO international standard) were compared with results from ELISAs specific to antibodies against the Spike protein (S-2P) and the receptor binding domain (RBD) as well as neutralization tests including nanoluciferase (nLUC80), live-virus (PRNT80), and a pseudovirus neutralizing antibody assay (PsVNA50). Results RBD-specific antibodies were already detectable by ACOV2S at the first time point of assessment (d15 after first vaccination), with seroconversion before in all but 2 participants (25 μg dose group); all had seroconverted by Day 29. Across all post-baseline visits, geometric mean concentration of antibody levels were 3.27-7.48-fold higher in the 100 μg compared with the 25 μg dose group. ACOV2S measurements were highly correlated with those from RBD ELISA (Pearson's r=0.938; p<0.0001) and S-2P ELISA (r=0.918; p<0.0001). For both ELISAs, heterogeneous baseline results and smaller increases in antibody levels following the second vs first vaccination compared with ACOV2S were observed. ACOV2S showed absence of any baseline noise indicating high specificity detecting vaccine-induced antibody response. Moderate-strong correlations were observed between ACOV2S and neutralization tests (nLUC80 r=0.933; PsVNA50, r=0.771; PRNT80, r=0.672; all p≤0.0001). Conclusion The Elecsys Anti-SARS-CoV-2 S assay (ACOV2S) can be regarded as a highly valuable method to assess and quantify the presence of RBD-directed antibodies against SARS-CoV-2 following vaccination, and may indicate the presence of neutralizing antibodies. As a fully automated and standardized method, ACOV2S could qualify as the method of choice for consistent quantification of vaccine-induced humoral response.


PEDIATRICS ◽  
1964 ◽  
Vol 34 (6) ◽  
pp. 761-770
Author(s):  
Marc Beem ◽  
Rosalie Egerer ◽  
Julia Anderson

The R.S. virus neutralization test was examined in terms of several factors bearing on the consistency and specificity of antibody response to a single strain (Randall) of this virus. It was found that this virus detected significant rises in antibody titer in 90% of 30 patients over 6 months of age who were infected with wild strains of R.S. virus between the years 1958 and 1962. Heterologous neutralizing antibodies to R.S. virus did not occur following human infections with various myxoviruses, adenoviruses, enteroviruses and herpesvirus. Indirect evidence was presented indicating that tile neutralizing activity of human serums is due to specific antibody and not due to non-specific, heat stable neutralizing substance. The titer of R.S. neutralizing antibodies was determined in the serums of 26 parturient mothers, and their 27 newborn babies, and 186 other individuals between the ages of 6 months and 69 years. Longitudinal observations of antibody titer were also conducted on 12 other infants. Neutralizing antibodies to R.S. virus were found to reach the term fetus at undiminished titer. In the longitudinal observations, serum neutralizing antibody titers were found to fall during the first months of life, decreasing by half in an average time of 43 days. Neutralizing antibodies, actively formed in response to R.S. virus infection, were observed to occur with rapidly increasing frequency in relation to age in subjects older than 6 months. These serologic findings indicated that among individuals residing in the metropolitan Chicago area, R.S. virus infection has been experienced by many during the first 2 years of life, most by school age, and all by 7 years of age. Geometric mean antibody titers were found to show a small, but probably significant, increase with age. The restriction of low titer reactors to pre-school children was noted. These serologic findings were interpreted as evidence that re-infections with R.S. virus occur, perhaps quite commonly.


Vaccines ◽  
2021 ◽  
Vol 9 (12) ◽  
pp. 1442
Author(s):  
Ruiqi Zhang ◽  
Ka-Wa Khong ◽  
Ka-Yi Leung ◽  
Danlei Liu ◽  
Yujing Fan ◽  
...  

Vaccinating recovered patients previously infected by COVID-19 with mRNA vaccines to boost their immune response against wild-type viruses (WT), we aimed to investigate whether vaccine platform and time of vaccination affect immunogenicity against the SARS-CoV-2 WT and Delta variant (DV). Convalescent patients infected by COVID-19 were recruited and received one booster dose of the BNT162b2 (PC-B) or CoronaVac (PC-C) vaccines, while SARS-CoV-2 naïve subjects received two doses of the BNT162b2 (CN-B) or CoronaVac (CN-C) vaccines. The neutralizing antibody in sera against the WT and DV was determined with live virus neutralization assay (vMN). The vMN geometric mean titre (GMT) against WT in recovered individuals previously infected by COVID-19 reduced significantly from 60.0 (95% confidence interval (CI), 46.5–77.4) to 33.9 (95% CI, 26.3–43.7) at 6 months post recovery. In the PC-B group, the BNT162b2 vaccine enhanced antibody response against WT and DV, with 22.3-fold and 20.4-fold increases, respectively. The PC-C group also showed 1.8-fold and 2.2-fold increases for WT and DV, respectively, after receiving the CoronaVac vaccine. There was a 10.6-fold increase in GMT in the CN-B group and a 1.3-fold increase in the CN-C group against DV after full vaccination. In both the PC-B and PC-C groups, there was no difference between GMT against WT and DV after vaccination. Subjects in the CN-B and CN-C groups showed inferior GMT against DV compared with GMT against WT after vaccination. In this study, one booster shot effectively enhanced the pre-existing neutralizing activity against WT and DV in recovered subjects.


Author(s):  
Kevin O. Saunders ◽  
Esther Lee ◽  
Robert Parks ◽  
David R. Martinez ◽  
Dapeng Li ◽  
...  

SUMMARYBetacoronaviruses (betaCoVs) caused the severe acute respiratory syndrome (SARS) and Middle East Respiratory Syndrome (MERS) outbreaks, and now the SARS-CoV-2 pandemic. Vaccines that elicit protective immune responses against SARS-CoV-2 and betaCoVs circulating in animals have the potential to prevent future betaCoV pandemics. Here, we show that immunization of macaques with a multimeric SARS-CoV-2 receptor binding domain (RBD) nanoparticle adjuvanted with 3M-052-Alum elicited cross-neutralizing antibody responses against SARS-CoV-1, SARS-CoV-2, batCoVs and the UK B.1.1.7 SARS-CoV-2 mutant virus. Nanoparticle vaccination resulted in a SARS-CoV-2 reciprocal geometric mean neutralization titer of 47,216, and robust protection against SARS-CoV-2 in macaque upper and lower respiratory tracts. Importantly, nucleoside-modified mRNA encoding a stabilized transmembrane spike or monomeric RBD protein also induced SARS-CoV-1 and batCoV cross-neutralizing antibodies, albeit at lower titers. These results demonstrate current mRNA vaccines may provide some protection from future zoonotic betaCoV outbreaks, and provide a platform for further development of pan-betaCoV nanoparticle vaccines.


2019 ◽  
Vol 12 (9) ◽  
pp. 1422-1427
Author(s):  
Jayalakshmi Vasu ◽  
Mouttou Vivek Srinivas ◽  
Prabhakar Xavier Antony ◽  
Jacob Thanislass ◽  
Vijayalakshmi Padmanaban ◽  
...  

Background and Aim: Canine parvovirus (CPV) is the most important viral cause of enteritis and mortality in pups. Evaluation and monitoring of pre- and post-vaccine immune responses may help to determine the efficacy of the current vaccination schedule being followed in pups in India. This study aimed to evaluate and monitor the pre- and post-vaccine immune responses of CPV vaccinated pups using hemagglutination inhibition (HI) assay. The neutralizing antibody titer levels were also detected using serum neutralization test (SNT). Materials and Methods: The pups were categorized into two groups, the double booster and the single booster groups. In this study, serum samples were subjected to HI and SNT for measuring the CPV antibody titer at frequent intervals for up to 6 months from 27 healthy pups following primary and booster CPV vaccinations. Results: The antibody titers in double booster pups reached their peaks at the 21st day after the second booster vaccination with a geometric mean (GM) of 3.57. The antibody titers in single booster pups reached their peaks at the 21st day after the first booster vaccination with a lower GM of 3.18. Conclusion: The double booster pups maintained a higher immune response throughout the period of the study compared to single booster pups though the difference in titers was not statistically significant. SNT results indicated that the raised antibody titer was also able to yield virus-neutralizing antibodies. No interfering maternally derived antibodies were found in the pups at the age of primary vaccination (45th day) in our study. Therefore, the second booster vaccination may be useful in maintaining the protective titer for a prolonged period.


2022 ◽  
Vol 12 (1) ◽  
pp. 68
Author(s):  
Chun-Yu Chen ◽  
Kuan-Ting Liu ◽  
Shin-Ru Shih ◽  
Jung-Jr Ye ◽  
Yih-Ting Chen ◽  
...  

Background: Data are lacking regarding predictors of quantification of neutralizing antibodies (nAbs) based on severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) 50% neutralization titer (NT50) after a single dose of COVID-19 vaccine in hemodialysis (HD) patients. Methods: This prospective single-center study enrolled 200 HD patients and 82 healthy subjects to estimate antibodies against the SARS-CoV-2 viral spike protein 1 and receptor-binding domain after a first dose of a COVID-19 vaccine (ChAdOx1 or mRNA-1273), measured by enzyme-linked immunosorbent assay and applied spline-based generalized additive model regression analysis to predict NT50 converted to international units. Results: After the first dose of ChAdOx1, multiple linear regression showed that age (p = 0.011) and cardiothoracic ratio (p = 0.002) were negatively associated with NT50. Older age (OR = 0.958, p = 0.052) and higher cardiothoracic ratio (OR < 0.001, p = 0.037) could predict negative humoral response (NT50 < 35.13 IU/mL). NT50 was lower in HD patients compared with healthy controls receiving ChAdOx1 (10.68 vs. 43.01 IU/m, p < 0.001) or mRNA-1273 (36.39 vs. 262.2 IU/mL, p < 0.001). ChAdOx1 elicited lower GMTs than mRNA-1273 in the HD cohort (10.68 vs. 36.39 IU/mL, p < 0.001) and in healthy controls (43.01 vs. 262.22 IU/mL, p < 0.001). Conclusion: High cardiothoracic ratio and old age could independently predict a decline in nAb titers in an HD cohort vaccinated with a single dose of ChAdOx1.


2021 ◽  
Author(s):  
Yu-An Kung ◽  
Chung-Guei Huang ◽  
Sheng-Yu Huang ◽  
Kuan-Ting Liu ◽  
Peng-Nien Huang ◽  
...  

The World Health Organization (WHO) has highlighted the importance of an international standard (IS) for SARS-CoV-2 neutralizing antibody titer detection, with the aim of calibrating different diagnostic techniques. In this study, IS was applied to calibrate neutralizing antibody titers (IU/mL) and binding antibody titers (BAU/mL) in response to SARS-CoV-2 vaccines. Serum samples were collected from participants receiving the Moderna (n = 20) and Pfizer (n = 20) vaccines at three time points: pre-vaccination, after one dose, and after two doses. We obtained geometric mean titers of 1404.16 and 928.75 IU/mL for neutralizing antibodies after two doses of the Moderna and Pfizer vaccines, respectively. These values provide an important baseline for vaccine development and the implementation of non-inferiority trials. We also compared three commercially available kits from Roche, Abbott, and MeDiPro for the detection of COVID-19 antibodies based on binding affinity to S1 and/or RBD. Our results demonstrated that antibody titers measured by commercial assays are highly correlated with neutralizing antibody titers calibrated by IS.


Sign in / Sign up

Export Citation Format

Share Document