scholarly journals A Multi-Timescale Bilinear Model for Optimization and Control of HVAC Systems with Consistency

Energies ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 400 ◽  
Author(s):  
Zelin Nie ◽  
Feng Gao ◽  
Chao-Bo Yan

Reducing the energy consumption of the heating, ventilation, and air conditioning (HVAC) systems while ensuring users’ comfort is of both academic and practical significance. However, the-state-of-the-art of the optimization model of the HVAC system is that either the thermal dynamic model is simplified as a linear model, or the optimization model of the HVAC system is single-timescale, which leads to heavy computation burden. To balance the practicality and the overhead of computation, in this paper, a multi-timescale bilinear model of HVAC systems is proposed. To guarantee the consistency of models in different timescales, the fast timescale model is built first with a bilinear form, and then the slow timescale model is induced from the fast one, specifically, with a bilinear-like form. After a simplified replacement made for the bilinear-like part, this problem can be solved by a convexification method. Extensive numerical experiments have been conducted to validate the effectiveness of this model.

Author(s):  
Hamed Moradi ◽  
Majid Saffar-Avval

Heating, ventilation and air conditioning (HVAC) systems are equipments used to maintain satisfactory comfort conditions in buildings. Also, energy consumption of ventilated buildings highly depend on the design, performance and control of HVAC systems. In this paper, nonlinear model of a multi-variable HVAC system is considered in which the control inputs are the air and cool water flow rates. Using thermodynamics and heat transfer rules, differential and consequently state space equations of the system are represented. To achieve a good performance, dynamic variables such as output temperature and relative humidity must be controlled. Using input-output feedback linearization, a PI controller is designed. It is shown that by applying the controller, system tracks from one operating point to another with an appropriate specification of time response. In addition, using feedback linearization guarantees robustness of the system against the parametric uncertainties associated with dynamic model.


2021 ◽  
Vol 283 ◽  
pp. 01051
Author(s):  
Xiaolong Ruan ◽  
Yisong Yin

With the continuous growth of my country's economy and the continuous improvement of the people's economic level, the demand for the design of heating, ventilation and air conditioning systems has also increased. The HVAC system is very important in the building environment. When optimizing the relevant design, it is necessary to always consider the design details of the HVAC system and adjust the integrity of the design, especially to take preventive measures in areas where noise and vibration may occur to avoid heating serious problems caused by noise and general vibration when the communication system is running. This article outlines how to avoid and control common noise and vibration problems when designing HVAC projects.


2021 ◽  
Vol 261 ◽  
pp. 01013
Author(s):  
Changbao Guo

With the rapid development of modern society, the measurement and control requirements of key variables of air conditioning test technology are also increasing. When the parameters of HVAC system are measured and controlled, there are a large number of sensors and instruments used. When sensor failure or measurement error distortion occurs, the air conditioning system cannot operate normally and automatically. At the same time, some variables in the test parameters cannot be directly collected by the sensor. In order to solve these problems, researchers have focused on soft measurement technology in recent years, which provides a good breakthrough for the measurement and control of air conditioning system test parameters. This paper expounds the application of soft measurement technology in HVAC system.


1985 ◽  
Vol 107 (4) ◽  
pp. 284-289 ◽  
Author(s):  
P. B. Usoro ◽  
I. C. Schick ◽  
S. Negahdaripour

Although Energy Management and Control Systems (EMCS) have since the early 1970’s contributed significantly to the reduction (20-40 percent) of energy use in buildings without sacrificing occupants’ comfort, their full capabilities have not been completely realized. This is in part due to their inability to quickly detect and compensate for failures in the Heating, Ventilation and Air Conditioning (HVAC) system. In fact, no matter how good the control scheme for the HVAC system might be, the presence of undetected faults can completely offset any expected savings. This paper presents a methodology for detecting faults in an HVAC system using a nonlinear mathematical model and an extended Kalman filter. The technique was implemented in a computer program and successfully used to detect “planted” faults in simulations of the air handler unit of an HVAC system. Test results are presented to demonstrate the effectiveness of the methodology.


2012 ◽  
Vol 452-453 ◽  
pp. 460-468
Author(s):  
Davood Dehestani ◽  
Jafar Madadnia ◽  
Homa Koosha ◽  
Fahimeh Eftekhari

Due to the growing demand on high efficient heat ventilation and air conditioning (HVAC) systems, how to improve the efficiency of HVAC system regarding reduces energy consumption of system has become one of the critical issues. Reports indicate that efficiency and availability are heavily dependent upon high reliability and maintainability. Recently, the concept of e-maintenance has been introduced to reduce the cost of maintenance. In e-maintenance systems, the fault detection and isolation (FDI) system plays a crucial role for identifying failures. Finding healthy HVAC source as the reference for health monitoring is the main aim in this area. To dispel this concern a comprehensive transient model of heat ventilation and air conditioning (HVAC) systems is developed in this study. The transient model equations can be solved efficiently using MATLAB coding and simulation technique. Our proposed model is validated against real HVAC system regarding different parts of HVAC. The developed model in this study can be used for a pre tuning of control system and put to good use for fault detection and isolation in order to accomplish high-quality health monitoring and result in energy saving. Fan supply consider as faulty device of HVAC system with six fault type. A sensitivity analysis based on evaluated model shows us three features are sensitive to all faults type and three auxiliary features are sensitive to some faults. The magnitude and trait of features are a good potential for automatic fault tolerant system based on machine learning systems


2021 ◽  
Author(s):  
◽  
Anthony Gates

<p>Template energy calculation models that have been produced by the Building Energy End-use Study (BEES) team are used to quickly and reliably model commercial buildings and calculate their energy performance. The template models contain standardised equipment, lighting, and occupancy loads; cooling and heating requirements are calculated using an ideal loads air system. Using seven buildings, Cory et al. 2011a have demonstrated that the template models have the potential to closely match the monthly energy performance of detailed (individually purpose built) models and the real buildings. Three of these models were within the ±5% acceptable tolerance to be considered calibrated. The four template models that were not within the acceptable tolerance have been identified to have complex Heating, Ventilation, and Air Conditioning (HVAC) systems that the ideal loads air systems could not replicate. Because HVAC systems consume one of the largest proportions of energy in commercial buildings, this has a significant impact on the reliability of the template models. To address this issue, a set of detailed HVAC systems were needed to replace the ideal loads air systems. Due to HVAC system parameters not being collected by the BEES team and the lack of published modelling input parameters available, it is unknown what values are reasonable to use in the models. This study used a Delphi survey to collect real building information of the commonly installed HVAC systems in New Zealand commercial buildings. The survey formed a consensus between HVAC engineers that determined what the most commonly installed systems are and their associated performance values. The outcome of the survey was a documented set of system types and modelling input parameters that are representative of New Zealand HVAC systems. The responses of the survey were used to produce a set of HVAC system templates that replace the ideal loads air systems. The HVAC template models updated the software default parameter values with values that are representative of commonly installed systems in New Zealand. The importance of the updated input values was illustrated through a comparison of the calculated monthly energy consumption. The resulting difference in energy consumption using the updated parameter values is typically <5% monthly; at worst it is 75% for Variable Air Volume (VAV) system in the Wellington climate during June.</p>


2021 ◽  
Vol 12 (1) ◽  
pp. 7
Author(s):  
Francesco Cigarini ◽  
Tu-Anh Fay ◽  
Nikolay Artemenko ◽  
Dietmar Göhlich

In battery electric buses (e-buses), the substantial energy consumption of the heating, ventilation, and air conditioning (HVAC) system can cause significant reductions of the available travel range. Additionally, HVAC systems are often operated at higher levels than what required for the thermal comfort of the passengers. Therefore, this paper proposes a method to experimentally investigate the influence of the HVAC system on the energy consumption and thermal comfort in a 12m e-bus. An appropriate thermal comfort model is identified and the required climatic input parameters are selected and measured with self-developed sensor stations. The energy consumption of the e-bus, the state of charge (SoC) of the battery and the available travel range are measured by an embedded data logger. Climatic measurements are then performed with heating on and off on a Berlin bus line in winter conditions. The results show that the energy consumption of the e-bus is increased by a factor of 1.9 with heating on, while both the SoC and travel range are reduced accordingly. Comparing the thermal comfort with heating on and off, a decrease from “comfortable” to “slightly uncomfortable but acceptable” is observed.


2016 ◽  
Vol 2016 ◽  
pp. 1-11
Author(s):  
M. C. Basile ◽  
V. Bruni ◽  
F. Buccolini ◽  
D. De Canditiis ◽  
S. Tagliaferri ◽  
...  

This paper presents a methodology for assessing and monitoring the cleaning state of a heating, ventilation, and air conditioning (HVAC) system of a building. It consists of a noninvasive method for measuring the amount of dust in the whole ventilation system, that is, the set of filters and air ducts. Specifically, it defines the minimum amount of measurements, their time table, locations, and acquisition conditions. The proposed method promotes early intervention on the system and it guarantees high indoor air quality and proper HVAC working conditions. The effectiveness of the method is proved by some experimental results on different study cases.