scholarly journals Review of Intelligent Control Systems for Natural Ventilation as Passive Cooling Strategy for UK Buildings and Similar Climatic Conditions

Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4388
Author(s):  
Esmail Mahmoudi Saber ◽  
Issa Chaer ◽  
Aaron Gillich ◽  
Bukola Grace Ekpeti

Natural ventilation is gaining more attention from architects and engineers as an alternative way of cooling and ventilating indoor spaces. Based on building types, it could save between 13 and 40% of the building cooling energy use. However, this needs to be implemented and operated with a well-designed and integrated control system to avoid triggering discomfort for occupants. This paper seeks to review, discuss, and contribute to existing knowledge on the application of control systems and optimisation theories of naturally ventilated buildings to produce the best performance. The study finally presents an outstanding theoretical context and practical implementation for researchers seeking to explore the use of intelligent controls for optimal output in the pursuit to help solve intricate control problems in the building industry and suggests advanced control systems such as fuzzy logic control as an effective control strategy for an integrated control of ventilation, heating and cooling systems.

Author(s):  
Frank Butera ◽  
Keith Hewett

Maximising cross ventilation is a low energy method of naturally ventilating and providing heating and cooling to deep plan spaces. Significant reduction in the emission of greenhouse gases can be achieved through minimising the use of mechanical systems in regions with climatic conditions that support the use of natural ventilation. Arup has provided input into the design of a louvered facade for the control of external noise for Brisbane Domestic Airport. A full scale prototype facade was constructed and noise transmission loss measurements were undertaken. The results indicate that significant noise reduction can be achieved to enable compliance with the internal noise limits for airport terminals, whilst using natural ventilation. The findings from this research will directly benefit building designers and innovators in the pursuit of achieving sustainable building design.


2019 ◽  
Vol 111 ◽  
pp. 04011
Author(s):  
Catalin Lungu ◽  
Florin Baltaretu

In this paper the authors describe a HVAC innovative system using an integrated greenhouse for heating and cooling an office building. The ventilation system allows natural (night) or mechanical ventilation and the passive cooling during the summer, including cold storage in the building structure and the PCM plywood and the refrigeration energy use during the day. Natural ventilation occurs when the wind or the Venturi effect, created by the « hat » that supports the photovoltaic panels, is strong enough; otherwise, a variable speed exhaust fan mounted on top of the building is used. The plants inside the greenhouse can produce O2 under certain conditions necessary for refreshing the ventilation air. The environment of the greenhouse allows air humidification naturally, without the use of humidifiers. If the greenhouse is sufficiently insulated in winter, it can be used in the ventilation process: the air intake from offices through the greenhouse, humidified and enriched in O2 (premixed, if necessary, with fresh air) reaches the general air treatment unit, and then sent back. The process is similar in the summer, but without recirculation, due to the humidity of the air extracted from offices. Stale air humidification enhances the thermal transfer process from the desiccant collector.


2017 ◽  
Vol 12 (2) ◽  
pp. 28-37
Author(s):  
Friedrich Sick ◽  
Lioba Ross

INTRODUCTION On the basis of dynamic building simulations within a maximal realistic framework, it may be useful with respect to the overall energy balance to dispense with pursuing a minimal surface/volume ratio of buildings—thus minimizing heat losses across the building shell—in favor of solar energy use. The specific use of the building (here: office or residential) plays a crucial role. Balancing the energy demand for heating and cooling and a possible photovoltaic yield, a surplus is possible in all cases under investigation. Long, low unobstructed buildings perform best due to large portions of roof area suitable for solar energy use. For tall buildings with less roof area, parts of the facades may be used for solar applications which makes them also perform better than compact designs. If the total energy demand including auxiliary energy for HVAC and especially electricity for the office and residential usages, respectively, is considered, compact cubatures of the size considered here (about 3500 m2) are not capable of providing positive energy balances. Residential usage performs worse than office use. Investigations are performed for the climatic conditions of Berlin, Germany.


1978 ◽  
Author(s):  
J. H. Pejsa ◽  
W. W. Bassett ◽  
S. A. Wenzler ◽  
K. H. Nguyen ◽  
T. J. Olson

2020 ◽  
Vol 12 (5) ◽  
pp. 1829 ◽  
Author(s):  
Tiantian Du ◽  
Sabine Jansen ◽  
Michela Turrin ◽  
Andy van den Dobbelsteen

As one of the most important design tasks of building design, space layout design affects the building energy performance (BEP). In order to investigate the effect, a literature review of relevant papers was performed. Ten relevant articles were found and reviewed in detail. First, a methodology for studying the effects of space layouts on BEP were proposed regarding design variables, energy indicators and BEP calculation methods, and the methodologies used in the 10 articles were reviewed. Then, the effects of space layouts on energy use and occupant comfort were analysed separately. The results show that the energy use for heating, cooling, lighting and ventilation is highly affected by space layouts, as well as thermal and visual comfort. The effects of space layouts on energy use are higher than on occupant comfort. By changing space layouts, the resulting reductions in the annual final energy for heating and cooling demands were up to 14% and 57%, respectively, in an office building in Sweden. The resulting reductions in the lighting demand of peak summer and winter were up to 67% and 43%, respectively, for the case of an office building in the UK, and the resulting reduction in the air volume supplied by natural ventilation was 65%. The influence of other design parameters, i.e., occupancy and window to wall ratio, on the effects of space layouts on BEP was also identified.


2018 ◽  
Vol 44 ◽  
pp. 00016
Author(s):  
Wojciech Cepiński ◽  
Bartosz Szmigiero

Ecological, natural ways of obtaining energy for building cooling are becoming more and more popular around the world. Reducing energy demand and increasing the renewable energy use can be achieved for example by using radiative cooling. Depending on climatic conditions and the type of cooling system, radiative cooling is able to cover a part of refrigeration needs. The document presents the possible energy yield from using radiative cooling in systems operating at respective parameters in polish climatic conditions.


2019 ◽  
Vol 111 ◽  
pp. 05008 ◽  
Author(s):  
Taha Arghand ◽  
Jan-Olof Dalenbäck ◽  
Anders Trüschel ◽  
Saqib Javed

Designing appropriate control systems for radiant heating and cooling terminals entails an understanding of their dynamic behaviour. This study experimentally investigates the dynamic response of a room with convective and radiant cooling systems. The experiments were performed in a 12.6 m2 large test room outfitted as a single-office room. The main cooling system was radiant ceiling panels which covered 70% of the ceiling area. The thermal performance of the radiant system was compared to that of a fan-coil unit (FCU). The results from the step response test showed that the time constant of the room for the radiant system was shorter than for the convective one, indicating faster changes in room temperature by the radiant system. Furthermore, controlling the FCU with similar control system tuned for ceiling panels increased the hysteresis gap in the room air temperature from 0.4 K to 0.8 K. This indicates that control systems for low-mass radiant systems and convective systems might be applied to each other, but on-site tuning is required to omit the offset (persistent error). In this study, controlling room temperature with ceiling panels did not benefit from using an operative temperature sensor to provide feedback signal to the control system. However, the pump energy use was moderately decreased by 14%.


2020 ◽  
Vol 14 (3) ◽  
pp. 7109-7124
Author(s):  
Nasreddine Sakhri ◽  
Younes Menni ◽  
Houari Ameur ◽  
Ali J. Chamkha ◽  
Noureddine Kaid ◽  
...  

The wind catcher or wind tower is a natural ventilation technique that has been employed in the Middle East region and still until nowadays. The present paper aims to study the effect of the one-sided position of a wind catcher device against the ventilated space or building geometry and its natural ventilation performance. Four models based on the traditional design of a one-sided wind catcher are studied and compared. The study is achieved under the climatic conditions of the South-west of Algeria (arid region). The obtained results showed that the front and Takhtabush’s models were able to create the maximum pressure difference (ΔP) between the windward and leeward of the tower-house system. Internal airflow velocities increased with the increase of wind speed in all studied models. For example, at Vwind = 2 m/s, the internal flow velocities were 1.7, 1.8, 1.3, and 2.5 m/s for model 1, 2, 3, and 4, respectively. However, at Vwind = 6 m/s, the internal flow velocities were 5.6, 5.5, 2.5, and 7 m/s for model 1, 2, 3, and 4, respectively. The higher internal airflow velocities are given by Takhtabush, traditional, front and middle tower models, respectively, with a reduction rate between the tower outlet and occupied space by 72, 42, 36, and 33% for the middle tower, Takhtabush, traditional tower, and the front model tower, respectively. This reduction is due to the due to internal flow resistance. The third part of the study investigates the effect of window (exist opening) position on the opposite wall. The upper, middle and lower window positions are studied and compared. The air stagnation or recirculation zone inside the ventilated space reduced from 55% with the lower window to 46% for the middle window and reached 35% for the upper window position. The Front and Takhtabush models for the one-sided wind catcher with an upper window position are highly recommended for the wind-driven natural ventilation in residential houses that are located in arid regions.


Author(s):  
Peter Rez

Most of the energy used by buildings goes into heating and cooling. For small buildings, such as houses, heat transfer by conduction through the sides is as much as, if not greater than, the heat transfer from air exchanges with the outside. For large buildings, such as offices and factories, the greater volume-to-surface ratio means that air exchanges are more significant. Lights, people and equipment can make significant contributions. Since the energy used depends on the difference in temperature between the inside and the outside, local climate is the most important factor that determines energy use. If heating is required, it is usually more efficient to use a heat pump than to directly burn a fossil fuel. Using diffuse daylight is always more energy efficient than lighting up a room with artificial lights, although this will set a limit on the size of buildings.