scholarly journals A Study of Optimal Specifications for Light Shelves with Photovoltaic Modules to Improve Indoor Comfort and Save Building Energy

Author(s):  
Heangwoo Lee ◽  
Xiaolong Zhao ◽  
Janghoo Seo

Recent studies on light shelves found that building energy efficiency could be maximized by applying photovoltaic (PV) modules to light shelf reflectors. Although PV modules generate a substantial amount of heat and change the consumption of indoor heating and cooling energy, performance evaluations carried out thus far have not considered these factors. This study validated the effectiveness of PV module light shelves and determined optimal specifications while considering heating and cooling energy savings. A full-scale testbed was built to evaluate performance according to light shelf variables. The uniformity ratio was found to improve according to the light shelf angle value and decreased as the PV module installation area increased. It was determined that PV modules should be considered in the design of light shelves as their daylighting and concentration efficiency change according to their angles. PV modules installed on light shelves were also found to change the indoor cooling and heating environment; the degree of such change increased as the area of the PV module increased. Lastly, light shelf specifications for reducing building energy, including heating and cooling energy, were not found to apply to PV modules since PV modules on light shelf reflectors increase building energy consumption.

Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1080
Author(s):  
Mamdooh Alwetaishi ◽  
Omrane Benjeddou

The concern regarding local responsive building design has gained more attention globally as of late. This is due to the issue of the rapid increase in energy consumption in buildings for the purpose of heating and cooling. This has become a crucial issue in educational buildings and especially in schools. The major issue in school buildings in Saudi Arabia is that they are a form of prototype school building design (PSBD). As a result, if there is any concern in the design stage and in relation to the selection of building materials, this will spread throughout the region. In addition to that, the design is repeated regardless of the climate variation within the kingdom of Saudi Arabia. This research will focus on the influence of the window to wall ratio on the energy load in various orientations and different climatic regions. The research will use the energy computer tool TAS Environmental Design Solution Limited (EDSL) to calculate the energy load as well as solar gain. During the visit to the sample schools, a globe thermometer will be used to monitor the globe temperature in the classrooms. This research introduces a framework to assist architects and engineers in selecting the proper window to wall ratio (WWR) in each direction within the same building based on adequate natural light with a minimum reliance on energy load. For ultimate WWR for energy performance and daylight, the WWR should range from 20% to 30%, depending on orientation, in order to provide the optimal daylight factor combined with building energy efficiency. This ratio can be slightly greater in higher altitude locations.


2011 ◽  
Vol 250-253 ◽  
pp. 3035-3038 ◽  
Author(s):  
Zheng Quan Liu ◽  
Yi Wang Bao

Building-integrated photovoltaics (BIPV) is a relatively recent new application of photovoltaic (PV) energy technologies whose energy output is affected by many design-related factors including PV module technologies, installation orientation, tilt and shadow range of solar panels. The shading analysis of a residential house’s PV roof in Beijing was conducted by using building analysis program Autodesk Ecotect 2010. Analysis result shows that there is no shadow on the PV roof from 9a.m to 4p.m in winter solstice when the solar altitude angle reaches minimum, which ensures almost no shading losses for the PV modules over the year. The differences in monthly energy output were compared in the case of different installation tilt of solar panels and PV module technologies. Finally, the contribution to the building energy of the PV roof was discussed. The results show that appropriate design and selection of PV modules can compensate for the energy requirements for building heating and cooling to some extent.


2018 ◽  
Vol 22 (Suppl. 5) ◽  
pp. 1499-1509
Author(s):  
Miomir Vasov ◽  
Jelena Stevanovic ◽  
Veliborka Bogdanovic ◽  
Marko Ignjatovic ◽  
Dusan Randjelovic

Buildings are one of the biggest energy consumers in urban environments, so its efficient use represents a constant challenge. In public objects and households, a large part of the energy is used for heating and cooling. The orientation of the object, as well as the overall heat transfer coefficient (U-value) of transparent and non-transparent parts of the envelope, can have a significant impact on building energy needs. In this paper, analysis of the influence of different orientations, U-values of envelope elements, and size of windows on annual heating and cooling energy for an office building in city of Nis, Serbia, is presented. Model of the building was made in the Google SketchUp software, while the results of energy performance were obtained using EnergyPlus and jEplus, taking into ac-count the parameters of thermal comfort and climatic data for the area of city of Nis. Obtained results showed that, for varied parameters, the maximum difference in annual heating energy is 15129.4 kWh, i. e per m2 27.75 kWh/m2, while the maximum difference in annual cooling energy is 14356.1 kWh, i. e per m2 26.33 kWh/m2. Considering that differences in energy consumption are significant, analysis of these parameters in the early stage of design process can affect on increase of building energy efficiency.


2016 ◽  
Vol 38 (1) ◽  
pp. 64-88 ◽  
Author(s):  
N Belkacem ◽  
L Loukarfi ◽  
M Missoum ◽  
H Naji ◽  
A Khelil ◽  
...  

Bioclimatic architecture strategies and solar active systems contribute strongly to the reduction of building energy demand and achieving thermal comfort for its occupants over the whole year. This paper deals with the study of the energy performance improvement of a pilot bioclimatic house located in Algiers (Algeria). First, a series of experimental measures are conducted during cold period to show the effect of passive and active solar gains on the improvement of the indoor air temperature of the house. Then, a dynamic model of a solar heating system coupled with a bioclimatic house has been developed using TRNSYS software and validated with experimental data. The validated model has been used to establish the energy balance of the pilot bioclimatic house without solar heating system and to compare them to those of a conventional house. Finally, the improvement of the energy balance of the pilot bioclimatic house has been done by passive and active ways. The passive one includes the increase of south facing windows size and the use of night cooling with the use of shading device in summer. The active one consists of the integration of a solar heating system. Furthermore, an environmental study has been performed. The experimental results show that the energy requirements of a pilot bioclimatic house are very low which is suitable for the use of solar heating system in building. The simulation results show that the application of bioclimatic strategies is a better way to provide thermal comfort in summer and decrease the space heating energy demand of the house with 48.70%. The active solar system will cover 67.74% of the energy demand for heating of the house. These energy savings generate a significant reduction in CO2 emissions. Practical application: This work will enable engineers and designers of modern buildings of buildings in a Mediterranean climate to improve building energy efficiency and reduce CO2 emissions by a conjunction of different passive heating and cooling techniques such as insulation, thermal mass, window shades, night ventilation, and the solar heating system. The paper provides designers an effective strategy in terms of energy savings and indoor thermal comfort while reducing CO2 emissions.


Author(s):  
James P. Miller ◽  
Michael Deru ◽  
Kyle Benne ◽  
Alexander Zhivov ◽  
Dale Herron

Rising energy costs and the desire to reduce energy consumption dictates a need for significantly improved building energy performance. Three technologies that have potential to save energy and improve sustainability of buildings are dedicated outdoor air systems (DOAS), radiant heating and cooling systems and tighter building envelopes. Although individually applying innovative technologies may incrementally improve building energy performance, more significant payoffs are realized when compatible technologies are integrated into an optimized system. Fortunately, DOAS, radiant heating and cooling systems and improved building envelopes are highly compatible. To investigate the energy savings potential of these three technologies, whole building energy simulations were performed for a barracks facility and an administration facility in 15 U.S. climate zones and 16 international locations. The baseline facilities were assumed to be existing buildings with VAV HVAC systems (admin facilities) and packaged HVAC systems (barracks facilities). The energy simulations were adjusted for each location for optimal energy and humidity control performance. The results show that the upgraded facilities realized total building energy savings between 20% and 40% and improved humidity control when compared to baseline building performance.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 749
Author(s):  
John H. Scofield ◽  
Susannah Brodnitz ◽  
Jakob Cornell ◽  
Tian Liang ◽  
Thomas Scofield

In this work, we present results from the largest study of measured, whole-building energy performance for commercial LEED-certified buildings, using 2016 energy use data that were obtained for 4417 commercial office buildings (114 million m2) from municipal energy benchmarking disclosures for 10 major U.S. cities. The properties included 551 buildings (31 million m2) that we identified as LEED-certified. Annual energy use and greenhouse gas (GHG) emission were compared between LEED and non-LEED offices on a city-by-city basis and in aggregate. In aggregate, LEED offices demonstrated 11% site energy savings but only 7% savings in source energy and GHG emission. LEED offices saved 26% in non-electric energy but demonstrated no significant savings in electric energy. LEED savings in GHG and source energy increased to 10% when compared with newer, non-LEED offices. We also compared the measured energy savings for individual buildings with their projected savings, as determined by LEED points awarded for energy optimization. This analysis uncovered minimal correlation, i.e., an R2 < 1% for New Construction (NC) and Core and Shell (CS), and 8% for Existing Euildings (EB). The total measured site energy savings for LEED-NC and LEED-CS was 11% lower than projected while the total measured source energy savings for LEED-EB was 81% lower than projected. Only LEED offices certified at the gold level demonstrated statistically significant savings in source energy and greenhouse gas emissions as compared with non-LEED offices.


Buildings ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 94
Author(s):  
Tara L. Cavalline ◽  
Jorge Gallegos ◽  
Reid W. Castrodale ◽  
Charles Freeman ◽  
Jerry Liner ◽  
...  

Due to their porous nature, lightweight aggregates have been shown to exhibit thermal properties that are advantageous when used in building materials such as lightweight concrete, grout, mortar, and concrete masonry units. Limited data exist on the thermal properties of materials that incorporate lightweight aggregate where the pore system has not been altered, and very few studies have been performed to quantify the building energy performance of structures constructed using lightweight building materials in commonly utilized structural and building envelope components. In this study, several lightweight concrete and masonry building materials were tested to determine the thermal properties of the bulk materials, providing more accurate inputs to building energy simulation than have previously been used. These properties were used in EnergyPlus building energy simulation models for several types of commercial structures for which materials containing lightweight aggregates are an alternative commonly considered for economic and aesthetic reasons. In a simple model, use of sand lightweight concrete resulted in prediction of 15–17% heating energy savings and 10% cooling energy savings, while use of all lightweight concrete resulted in prediction of approximately 35–40% heating energy savings and 30% cooling energy savings. In more complex EnergyPlus reference models, results indicated superior thermal performance of lightweight aggregate building materials in 48 of 50 building energy simulations. Predicted energy savings for the five models ranged from 0.2% to 6.4%.


2017 ◽  
Vol 2017 ◽  
pp. 1-19 ◽  
Author(s):  
Vandana Jha ◽  
Uday Shankar Triar

This paper proposes an improved generalized method for evaluation of parameters, modeling, and simulation of photovoltaic modules. A new concept “Level of Improvement” has been proposed for evaluating unknown parameters of the nonlinear I-V equation of the single-diode model of PV module at any environmental condition, taking the manufacturer-specified data at Standard Test Conditions as inputs. The main contribution of the new concept is the improvement in the accuracy of values of evaluated parameters up to various levels and is based on mathematical equations of PV modules. The proposed evaluating method is implemented by MATLAB programming and, for demonstration, by using the values of parameters of the I-V equation obtained from programming results, a PV module model is build with MATLAB. The parameters evaluated by the proposed technique are validated with the datasheet values of six different commercially available PV modules (thin film, monocrystalline, and polycrystalline) at Standard Test Conditions and Nominal Operating Cell Temperature Conditions. The module output characteristics generated by the proposed method are validated with experimental data of FS-270 PV module. The effects of variation of ideality factor and resistances on output characteristics are also studied. The superiority of the proposed technique is proved.


Author(s):  
Nsed Ayip Akonjom ◽  
John Iyang Umuji ◽  
Ukoette Jeremiah Ekah

This central idea of this research is to investigate how voltage, current, power output and efficiency of polycrystalline photovoltaic (PV) modules installed in a Guinea Savanna and Mangrove Swamp is affected by temperature, relative humidity and irradiance. The study locations are Calabar (mangrove swamp) and Ogoja (guinea savanna), in Cross River State, Nigeria. Two polycrystalline PV modules of exact specification mounted on a platform one-metre-high above the ground were used. A digital solar power meter (SM206) and a digital solar flux meter (MS 6616) was used to monitor and measure solar power and solar flux reaching the PV modules. A digital hygrometer and thermometer (KT-908) were used to monitor and measure the relative humidity and ambient temperature level at the height of installation and a digital multimeter (M880C+) accompanied with a temperature sensor was used to monitor voltage, current and panel temperature values from the modules. Analysis of the collected data reveals that the efficiency of the modules were not constant throughout the day. However, a higher voltage production and efficiency level was obtained for the PV module installed in Ogoja than that installed in Calabar under their respective levels of relative humidity, temperature and irradiance.