scholarly journals Removal of Composite Restoration from the Root Surface in the Cervical Region Using Er: YAG Laser and Drill—In Vitro Study

Materials ◽  
2020 ◽  
Vol 13 (13) ◽  
pp. 3027 ◽  
Author(s):  
Wojciech Zakrzewski ◽  
Maciej Dobrzynski ◽  
Piotr Kuropka ◽  
Jacek Matys ◽  
Malgorzata Malecka ◽  
...  

Background: Recently, the defects of the tooth surface in the cervical region are often restored using composite filling materials. It should meet the needs of the patients regarding esthetics and material stability. The aim of the study was to analyze the tooth root surface at the cervical region after the removal of the composite filling material by means of the Erbium-doped Yttrium Aluminium Garnet (Er: YAG) laser or drill using the scanning electron microscopy (SEM) and fluorescence microscopy. Materials and Methods: For the purposes of this study, 14 premolar teeth (n = 14) were removed due to orthodontic reasons. The rectangular shape cavities with 3 mm in width and 1.5 mm in height were prepared with a 0.8 mm bur on high-speed contra-angle in the tooth surface just below cemento-enamel junction (CEJ) and filled with the composite material. The composite material was removed with the Er: YAG laser at a power of 3.4 W, energy 170 mJ, frequency 20 Hz, pulse duration 300 μs, tip diameter 0.8 mm, air/fluid cooling 3 mL/s, and time of irradiation: 6 sec, at a distance from teeth of 2 mm (G1 group, n = 7) or a high-speed contra-angle bur (G2 group, n = 7). After the removal of composite material, the surfaces of teeth were examined using the scanning electron microscopy (SEM) and fluorescence microscopy. Results: The Er: YAG irradiation allowed to remove completely the composite material from the tooth cavity. The study confirmed, that the ends of collagen fibers were only partially denatured after the Er: YAG laser application. Conclusion: It has been proved that using the Er: YAG laser is an effective and safe method of composite removal for the dentin surface.

Author(s):  
M. T. Postek ◽  
A. E. Vladar

One of the major advancements applied to scanning electron microscopy (SEM) during the past 10 years has been the development and application of digital imaging technology. Advancements in technology, notably the availability of less expensive, high-density memory chips and the development of high speed analog-to-digital converters, mass storage and high performance central processing units have fostered this revolution. Today, most modern SEM instruments have digital electronics as a standard feature. These instruments, generally have 8 bit or 256 gray levels with, at least, 512 × 512 pixel density operating at TV rate. In addition, current slow-scan commercial frame-grabber cards, directly applicable to the SEM, can have upwards of 12-14 bit lateral resolution permitting image acquisition at 4096 × 4096 resolution or greater. The two major categories of SEM systems to which digital technology have been applied are:In the analog SEM system the scan generator is normally operated in an analog manner and the image is displayed in an analog or "slow scan" mode.


Author(s):  
Kazuyuki Koike ◽  
Hideo Matsuyama

Spin-polarized scanning electron microscopy (spin SEM), where the secondary electron spin polarization is used as the image signal, is a novel technique for magnetic domain observation. Since its first development by Koike and Hayakawa in 1984, several laboratories have extensively studied this technique and have greatly improved its capability for data extraction and its range of applications. This paper reviews the progress over the last few years.Almost all the high expectations initially held for spin SEM have been realized. A spatial resolution of several hundreds angstroms has been attained, which is nearly one order of magnitude higher than that of conventional methods for thick samples. Quantitative analysis of magnetization direction has been performed more easily than with conventional methods. Domain observation of the surface of three-dimensional samples has been confirmed to be possible. One of the drawbacks, a long image acquisition time, has been eased by combining highspeed image-signal processing with high speed scanning, although at the cost of image quality. By using spin SEM, the magnetic structure of a 180 degrees surface Neel wall, magnetic thin films, multilayered films, magnetic discs, etc., have been investigated.


2014 ◽  
Vol 971-973 ◽  
pp. 802-805
Author(s):  
Wei Feng Zhang ◽  
Li Yan ◽  
Fu Xia Zhang

For the problem of high-speed rotating centrifuge spindle fracture failures, relevant analyses are conducted from the perspective of microstructure, chemical composition and fracture mechanics by using scanning electron microscopy and related instruments. Experimental results and analyses indicate that the spindle fracture is fatigue failure, mainly caused by cold cracks generated on the journal surfacing. Based on the analysis results, improvements and measures are suggested to better solve the spindle weld fracture failure problems.


1994 ◽  
Vol 2 (4) ◽  
pp. 19-20 ◽  
Author(s):  
M.T. Postek ◽  
A.E. Vladar

One of the major advancements applied to scanning electron microscopy (SEM) during the past 10 years has been the development and application of digital imaging technology. Advancements in technology, notably the availability of less expensive, high-density memory chips and the development of high speed analog-to-digital converters, mass storage and high performance central processing units have fostered this revolution. Today, most modern SEM instruments have digital electronics as a standard feature. These instruments, generally have 8 bit or 256 gray levels with, at least, 512 X 512 pixel density operating at TV rate. In addition, current slow-scan commercial frame-grabber cards, directly applicable to the SEM, can have upwards of 12-14 bit lateral resolution permitting image acquisition at 4096 X 4096 resolution or greater.


Sign in / Sign up

Export Citation Format

Share Document