scholarly journals Improvement of the Electronic—Neuronal Interface by Natural Deposition of ECM

Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1378
Author(s):  
Tobias Weigel ◽  
Julian Brennecke ◽  
Jan Hansmann

The foreign body reaction to neuronal electrode implants limits potential applications as well as the therapeutic period. Developments in the basic electrode design might improve the tissue compatibility and thereby reduce the foreign body reaction. In this work, the approach of embedding 3D carbon nanofiber electrodes in extracellular matrix (ECM) synthesized by human fibroblasts for a compatible connection to neuronal cells was investigated. Porous electrode material was manufactured by solution coelectrospinning of polyacrylonitrile and polyamide as a fibrous porogen. Moreover, NaCl represented an additional particulate porogen. To achieve the required conductivity for an electrical interface, meshes were carbonized. Through the application of two different porogens, the electrodes’ flexibility and porosity was improved. Human dermal fibroblasts were cultured on the electrode surface for ECM generation and removed afterwards. Scanning electron microscopy imaging revealed a nano fibrous ECM network covering the carbon fibers. The collagen amount of the ECM coating was quantified by hydroxyproline-assays. The modification with the natural protein coating on the electrode functionality resulted in a minor increase of the electrical capacity, which slightly improved the already outstanding electrical interface properties. Increased cell numbers of SH-SY5Y cell line on ECM-modified electrodes demonstrated an improved cell adhesion. During cell differentiation, the natural ECM enhanced the formation of neurites regarding length and branching. The conducted experiments indicated the prevention of direct cell-electrode contacts by the modification, which might help to shield temporary the electrode from immunological cells to reduce the foreign body reaction and improve the electrodes’ tissue integration.

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Jiaxi Chen ◽  
Huiqun Zhou ◽  
Daping Xie ◽  
Yiming Niu

Abstract Background Implantation of a biomaterial may induce the foreign-body reaction to the host tissue that determines the outcome of the integration and the biological performance of the implants. The foreign-body reaction can be modulated by control of the material properties of the implants. Methods First, we synthesized methacrylated Bletilla striata Polysaccharide (BSP-MA) and constructed a series of open porous cryogels utilizing this material via the freezing-thawing treatment of solvent-precursors systems. Second, Pore size and modulus were measured to characterize the properties of BSP cryogels. Live/dead staining of cells and CCK-8 were performed to test the cytocompatibility of the scaffolds. In addition, the Real-Time qPCR experiments were carried for the tests. Finally, the BSP scaffolds were implanted subcutaneously to verify the foreign-body reaction between host tissue and materials. Results Our data demonstrated that cryogels with different pore sizes and modulus can be fabricated by just adjusting the concentration. Besides, the cryogels showed well cytocompatibility in the in vitro experiments and exhibited upregulated expression levels of pro-inflammation-related genes (Tnfa and Il1b) with the increase of pore size. In vivo experiments further proved that with the increase of pore size, more immune cells infiltrated into the inner zone of materials. The foreign-body reaction and the distribution of immune-regulatory cells could be modulated by tuning the material microstructure. Conclusions Collectively, our findings revealed Bletilla striata polysaccharide cryogel scaffold with different pore sizes can spatially control foreign-body reaction. The microstructure of cryogels could differentially guide the distribution of inflammatory cells, affect the formation of blood vessels and fibrous capsules, which eventually influence the material-tissue integration. This work demonstrates a practical strategy to regulate foreign body reaction and promote the performance of medical devices.


2021 ◽  
Vol 8 (12) ◽  
pp. 205
Author(s):  
Alexey Fayzullin ◽  
Alesia Bakulina ◽  
Karen Mikaelyan ◽  
Anatoly Shekhter ◽  
Anna Guller

Precise delivery of therapeutics to the target structures is essential for treatment efficiency and safety. Drug administration via conventional routes requires overcoming multiple transport barriers to achieve and maintain the local drug concentration and commonly results in unwanted off-target effects. Patients’ compliance with the treatment schedule remains another challenge. Implantable drug delivery systems (IDDSs) provide a way to solve these problems. IDDSs are bioengineering devices surgically placed inside the patient’s tissues to avoid first-pass metabolism and reduce the systemic toxicity of the drug by eluting the therapeutic payload in the vicinity of the target tissues. IDDSs present an impressive example of successful translation of the research and engineering findings to the patient’s bedside. It is envisaged that the IDDS technologies will grow exponentially in the coming years. However, to pave the way for this progress, it is essential to learn lessons from the past and present of IDDSs clinical applications. The efficiency and safety of the drug-eluting implants depend on the interactions between the device and the hosting tissues. In this review, we address this need and analyze the clinical landscape of the FDA-approved IDDSs applications in the context of the foreign body reaction, a key aspect of implant–tissue integration.


2015 ◽  
Vol 55 (1-2) ◽  
pp. 1-11 ◽  
Author(s):  
Andreas Lambertz ◽  
Kai Michael Schröder ◽  
Dominik Stefan Schöb ◽  
Marcel Binnebösel ◽  
Michael Anurov ◽  
...  

Background: Biocompatibility and tissue integration of a surgical suture are decisive factors for wound healing and therefore for the success of sutures. The optimal suture material is still under discussion. Polyvinylidene fluoride (PVDF) is described to have superior properties of biocompatibility and is therefore frequently used as a mesh component. Only little information is available about its use as a suture material. The aim of this study was to evaluate the biocompatibility of PVDF as a suture material in comparison to 5 different established sutures in a rat model. Methods: In 30 male rats, a monofilamental PVDF suture (Resopren®) and 5 established control suture materials [polyester (Miralene®), polytetrafluoroethylene (Gore®), poliglecaprone (Monocryl®), polydioxanone (Monoplus®), polyglactin 910 (Vicryl®), USP size 3-0] were placed in the subcutaneous layer of the abdominal wall without knot or tension. After 3, 7 or 21 days, the abdominal walls were explanted for histopathological and immunohistochemical investigation with special regard to the size and quality of foreign body granuloma and the length of the comet tail-like infiltrate (CTI). Results: The PVDF sutures showed the smallest size of foreign body granuloma (60 ± 14 µm) and the smallest CTI length (343 ± 60 µm) of all polymers after 21 days. Only PVDF (Resopren) and polydioxanone (Monoplus) showed a significant collagen I/III ratio increase between days 3 and 21 (p = 0.009 and p = 0.016). The quality of foreign body reaction regarding inflammation, proliferation and fibrotic remodeling was similar between all suture materials. Conclusions: Our data indicate that monofilamental PVDF sutures show a favorable foreign body reaction with small granuloma sizes and CTI length in comparison to established sutures. Its use as a suture material in general surgery could therefore be extended in the future. To reinforce these findings, further clinical studies need to be conducted.


2021 ◽  
Author(s):  
Jiaxi Chen ◽  
Huiqun Zhou ◽  
Daping Xie ◽  
Yiming Niu

Abstract BackgroundImplantation of a biomaterial may induce the foreign-body reaction to the host tissue that determines the outcome of the integration and the biological performance of the implant. The level of foreign-body reaction can be modulated by material properties.MethodsFirst, we synthesized methacrylated Bletilla striata Polysaccharide (BSP-MA) and constructed a series of open porous cryogels utilizing this material via the freezing-thawing treatment of solvent-precursors systems. Second, Pore size and rheology were measured to characterize the material properties of cryogels. Live/dead staining of cells and CCK-8 was performed to test the cytocompatibility of the scaffolds. In addition, the Real-Time qPCR experiments were carried for in vitro tests. Finally, the BSP scaffolds were implanted subcutaneously to verify the foreign-body reaction between host tissue and materials.ResultsOur data demonstrated that cryogels with different pore sizes and modulus can be fabricated by just adjusting the concentration. Besides, the cryogels show well cytocompatibility in the in vitro experiments and exhibited upregulated expression levels of pro-inflammation-related genes (Tnfa and Il1b) with the increase of pore size. In vivo experiments further proved that with the increase of pore size, more immune cells infiltrated into the inner zone of materials. The foreign-body reaction and the distribution of immune-regulatory cells could be modulated by tuning the material microstructure.ConclusionsCollectively, our findings revealed Bletilla striata polysaccharide cryogel scaffold with different pore sizes can spatially control foreign-body reaction. The microstructure of cryogels could differentially guide the distribution of inflammatory cells, affect the formation of blood vessels and fibrous capsules, which eventually influence the material-tissue integration. This work demonstrates a practical strategy to regulate foreign body response and promote the performance of medical devices.


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 1094.2-1095
Author(s):  
A. S. Siebuhr ◽  
S. F. Madsen ◽  
M. Karsdal ◽  
A. C. Bay-Jensen ◽  
P. Juhl

Background:Systemic sclerosis has vascular, inflammatory and fibrotic components, which may be associated with different growth factors and cytokines. Platelet derived growth factor (PDGF) is associated with the vasculature, whereas tumor necrosis factor beta (TGFβ) is associated with inflammation and fibrosis. We have developed a fibroblast model system of dermal fibrosis for anti-fibrotic drugs testing, but the effect of the fibroblasts mechanistic properties are unknown.Objectives:We investigated different mechanical capacities of PDGF and TGFβ treated human healthy dermal fibroblasts in the SiaJ setting.Methods:Primary human healthy dermal fibroblasts were grown in DMEM medium containing 0.4% fetal calf serum, ficoll (to produce a crowded environment) and ascorbic acid for up to 17 days. A wound was induced by scratching the cells at 0, 1, 3 or 7 days after treatment initiation. Wound closure was followed for 3 days. Contraction capacity was tested by creating gels of human fibroblasts produced collagens containing dermal fibroblasts and contraction was assessed at day 2 by calculating the percentage of gel size to total well size. Collagen type I, III and VI formation (PRO-C1, PRO-C3 and PRO-C6) and fibronectin (FBN-C) were evaluated by validated ELISAs (Nordic Bioscience). Gene expression was analyzed after 2 days in culture. Statistical analyses included One-way ANOVA and student’s t-test.Results:Generally, PDGF closed the wound in half the time of w/o and TGFβ, when treatment and cells are added concurrently or scratched one day after treatment initiation. When treatments were added 3 or 7 days prior to scratch, the cells treated with PDGF had proliferated to a higher degree than w/o and TGFβ. A consequence of this, was that when cells were scratch the sheet of cells produced was lifted from the bottom and fold over itself, leaving a much greater scratch than in the other treatments. However, despite this increased gap the PDGF treated cells closed the wound at the same time as w/o and TGFβ, confirming the results of the cells scratched at day 0 and 1.Inhibition of contraction by ML-7 of otherwise untreated cells inhibited contraction significantly compared to untreated cells alone (p=0.0009). Contraction was increased in both TGFβ and PDGF treated cells compared to untreated cells (both p<0.0001). TGFβ+ ML-7 inhibited the contraction to the level of w/o (p=0.0024), which was only 35% of ML-7 alone. In the contraction study the cells were terminated after 2 days of culture, thus prior to when biomarker of ECM remodeling is usually assessed. However, FBN-C was detectable and a significant release of fibronectin by TGFβ and PDGF compared to w/o was found in the supernatant (both p<0.0001). The gene expression of FBN was only increased with TGFβ (p<0.05) and not PDGF. ML-7 alone tended to decrease FBN-C and in combination with TGFβ the FBN level was significantly decreased compared to TGFβ alone (p<0.0001). However, the level of TGFβ+ML-7 was significantly higher than ML-7 alone (p=0.038).TGFβ increased the gene expression of most genes assessed, except Col6a1. PDGF increased the gene expression of Col3a1, Col5a1 and Col6a1 above the critical fold change of 2, but only significantly in Col5a1 and Col6a1 (both p<0.05).Conclusion:This study demonstrates that TGFβ and PDGF have different mechanical capacities in human healthy dermal fibroblasts; TGFβ increased gene expression of ECM related genes, such as collagens and have increased FBN release in the supernatant already 2 days after initial treatment. PDGF has increased contraction, proliferation and migratory capacities and less expression of ECM related genes and proteins.Disclosure of Interests:Anne Sofie Siebuhr Employee of: Nordic Bioscience, Sofie Falkenløve Madsen: None declared, Morten Karsdal Shareholder of: Nordic Bioscience A/S., Employee of: Full time employee at Nordic Bioscience A/S., Anne-Christine Bay-Jensen Shareholder of: Nordic Bioscience A/S, Employee of: Full time employee at Nordic Bioscience A/S., Pernille Juhl Employee of: Nordic Bioscience


2014 ◽  
Vol 2014 ◽  
pp. 1-2
Author(s):  
Rintaro Shibuya ◽  
Yuichiro Endo ◽  
Akihiro Fujisawa ◽  
Miki Tanioka ◽  
Yoshiki Miyachi

Pencil core granuloma is characterized by a delayed foreign-body reaction against retained fragments of pencil lead. Previous case reports presented pencil core granuloma resembling malignant melanoma, haemangioma, or soft tissue sarcoma. We present a case of pencil core granuloma arising from the palm 25 years after the initial injury. The patient presented a bluish nodule that had been present over 25 years before. The nodule initially measured 5 mm in diameter. However, five years before presentation, it suddenly enlarged to the size of 30 mm during six months. Computed tomography (CT) of the lesion revealed a linear radiopaque structure of 8 mm long with a mass on its distal end. Surgical resection revealed a bluish muddy mass and pencil lead. Histological examination revealed degenerative tissue with calcification surrounded by massive amounts of black granular material in the middle and lower dermis.


2011 ◽  
Vol 75 (11) ◽  
pp. 1455-1458 ◽  
Author(s):  
Hye Jin Lim ◽  
Eun-So Lee ◽  
Hun Yi Park ◽  
Keehyun Park ◽  
Yun-Hoon Choung

Sign in / Sign up

Export Citation Format

Share Document