scholarly journals Influence of Scanning-Aid Materials on the Accuracy and Time Efficiency of Intraoral Scanners for Full-Arch Digital Scanning: An In Vitro Study

Materials ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2340
Author(s):  
Hyun-Su Oh ◽  
Young-Jun Lim ◽  
Bongju Kim ◽  
Myung-Joo Kim ◽  
Ho-Beom Kwon ◽  
...  

This study was performed to verify the influence of scanning-aid materials on the accuracy and time efficiency of full-arch scanning with intraoral scanners. The full-arch reference model was constructed by a 3D printer and scanned with a model scanner to obtain the reference dataset. Four experimental groups (application of ScanCure (SC-80, ODS Co, Incheon, Korea), IP Scan Spray (IP-Division, Haimhausen, Germany) and Vita Powder Scan Spray (Vita Zahnfabrik, Stuttgart, Germany), and no treatment) were designed, and the scans were executed (trueness, n = 5) using two intraoral scanners: I500 (Medit Co., Seoul, Korea) and TRIOS (3shape, Copenhagen, Denmark). All acquired scan data were compared with the reference datasets using the 3D superimposition method and 2D linear measurements. In the 3D analysis, intragroup data were compared with each other (precision, n = 10). Time efficiency was also verified by comparing the scan times of the four experimental groups. In the 3D analysis, the root mean square (RMS) value of the precision of the scanned image was statistically significantly more accurate in the scanning-aid agent-treated groups than in the no-treatment group (p < 0.05). However, the RMS values of trueness and the types of scanning-aid materials were not significantly different. In the 2D measurements, the increased scan distance generated a greater distance deviation. The working time was significantly shorter in the scanning-aid agent groups than in the no-treatment group, with statistical significance (p < 0.05). Therefore, in clinical situations, the application of scanning-aid materials is recommended to reduce scanning time and more efficiently obtain the full-arch scanned image.

Author(s):  
Keunbada Son ◽  
Wan-Sun Lee ◽  
Kyu-Bok Lee

This in vitro study aimed to evaluate the 3D analysis for complete arch, half arch, and tooth preparation region by using four analysis software programs. The CAD reference model (CRM; N = 1 per region) and CAD test models (CTMs; N = 20 per software) of complete arch, half arch, and tooth preparation were obtained by using scanners. For both CRM and CTMs, mesh data other than the same area were deleted. For 3D analysis, four analysis software programs (Geomagic control X, GOM Inspect, Cloudcompare, and Materialise 3-matic) were used in the alignment of CRM and CTMs as well as in the 3D comparison. Root mean square (RMS) was regarded as the result of the 3D comparison. One-way analysis of variance and Tukey honestly significant difference tests were performed for statistical comparison of four analysis software programs (α = 0.05). In half-arch and tooth preparation region, the four analysis software programs showed a significant difference in RMS values (p < 0.001), but in complete-arch region, no significant difference was found among the four software programs (p = 0.139). As the area of the virtual cast for 3D analysis becomes smaller, variable results are obtained depending on the software program used, and the difference in results among software programs are not considered in the 3D analysis for complete-arch region.


Healthcare ◽  
2021 ◽  
Vol 9 (3) ◽  
pp. 246
Author(s):  
Giordano Celeghin ◽  
Giulio Franceschetti ◽  
Nicola Mobilio ◽  
Alberto Fasiol ◽  
Santo Catapano ◽  
...  

The purpose of this study is to define the accuracy of four intraoral scanners (IOS) through the analysis of digital impressions of a complete dental arch model. Eight metal inserts were placed on the model as reference points and then it was scanned with a laboratory scanner in order to obtain the reference model. Subsequently, the reference model was scanned with four IOS (Carestream 3600, CEREC Omnicam, True Definition Scanner, Trios 3Shape). Linear measurements were traced on an STL file between the chosen reference points and divided into four categories: three-element mesiodistal, five-element mesiodistal, diagonal, and contralateral measurements. The digital reference values for the measurements were then compared with the values obtained from the scans to analyze the accuracy of the IOS using ANOVA. There were no statistically significant differences between the measurements of the digital scans obtained with the four IOS systems for any of the measurement groups tested.


2019 ◽  
Vol 9 (16) ◽  
pp. 3395
Author(s):  
Duk-Yeon Kim ◽  
Keunbada Son ◽  
Kyu-bok Lee

This study aimed to evaluate the correlation between the cutting efficiency and bur eccentricity of high-speed handpieces. The prepared lithium disilicate samples were digitized using a 3D model scanner (reference model, RM) (n = 45), and the lithium disilicate samples were cut using three high-speed handpieces. To evaluate the cutting efficiency, the cut lithium disilicate sample was digitized (cutting model, CM), and the RM and CM were superimposed using a 3D analysis software. Bur eccentricity of the high-speed handpieces was measured using dedicated equipment. Statistical analyses were performed using an analysis software. The statistical differences in pairwise comparisons (α = 0.05) were analyzed using the Kruskal–Wallis and post hoc tests. The S-max M600 obtained a cutting efficiency of 6.13 mm3. TG-98 and TRAUS ATN-400 showed similar efficiencies of 2.914 and 3.05 mm3, respectively. There was a significant difference in the cutting efficiency of the S-max M600 compared with TG-98 and TRAUS ATN-400 (p < 0.001). S-max M600 had an eccentricity of 3.507 µm. TG-98 and TRAUS ATN-400 had eccentricities of 5.99 and 7.767 µm, respectively. There were statistically significant differences in the eccentricity among all the high-speed handpieces (p < 0.001).


2019 ◽  
Vol 10 (1) ◽  
pp. 74 ◽  
Author(s):  
Byung-hyun Kang ◽  
Keunbada Son ◽  
Kyu-bok Lee

This study aims to evaluate the accuracy of five different intraoral scanners and two different laboratory scanners for a complete arch. A computer-aided design (CAD) reference model (CRM) was obtained using industrial scanners. A CAD test model (CTM) was obtained using five types of intraoral scanners (CS3500, CS3600, Trios2, Trios3, and i500) and two types of laboratory scanners (3shape E1 and DOF) (N = 20). In addition, the CRM and CTM were superimposed using a 3D inspection software (Geomagic control X; 3D Systems) and 3D analysis was performed. In the 3D analysis, the accuracy was measured by the type of tooth, the anterior and posterior region, and the overall region. As for the statistical analysis of the accuracy, the differences were confirmed using the Kruskal–Wallis H test (α = 0.05). Also, the differences between the groups were analyzed by post-hoc tests including Mann–Whitney U-test and Bonferroni correction method (α = 0.0017). There was a significant difference in the scanning accuracy of the complete arch according to the type of scanner (P < 0.001). The i500 Group showed the lowest accuracy (143 ± 69.6 µm), while the 3Shape E1 Group was the most accurate (14.3 ± 0.3 µm). Also, the accuracy was lower in the posterior region than in the anterior region in all types of scanners (P < 0.001). Scanning accuracy of the complete arch differed depending on the type of scanner. While three types of intraoral scanners (CS3500, CS3600, Trios3) can be recommended for scanning of a complete arch, the two remaining types of intraoral scanners (Trios2 and i500) cannot be recommended.


2021 ◽  
pp. 014556132098606
Author(s):  
Nguyen Quynh Anh ◽  
Pawin Numthavaj ◽  
Thongchai Bhongmakapat

Objectives: This study compared the cerumen dissolution activities of 7.5% sodium bicarbonate, 5% potassium hydroxide, 10% lactic acid, 3% salicylic acid, 10% glycolic acid, and distilled water. Methods: An in vitro study was conducted with 36 cerumen samples. The cerumenolytic activities of the 6 agents were assessed by recording the degree of cerumen disintegration using digital photography at 15 minutes, 30 minutes, 1 hour, 2 hours, and 12 hours. The undissolved cerumen that remained after 12 hours was removed from the solutions and weighed after drying. Results: Potassium hydroxide showed the fastest cerumenolytic activity, dissolving a moderate amount of cerumen at 30 minutes, while glycolic acid and salicylic acid caused no visible changes in the cerumen samples. Samples treated with potassium hydroxide and sodium bicarbonate exhibited higher degrees of disintegration compared to samples treated with distilled water (odds ratio and 95% CI: 273.237 [0.203-367 470.4] and 1.129 [0.002-850.341], respectively). The greatest reduction in cerumen weight was associated with the use of sodium bicarbonate; however, this result did not reach statistical significance. Conclusions: Among the solutions tested, 5% potassium hydroxide showed the fastest dissolution activity, yielding moderate disintegration within only 30 minutes. In terms of residual cerumen weight within 12 hours, all solutions exhibited equivalent effectiveness in the disintegration of cerumen.


2021 ◽  
Vol 9 (6) ◽  
pp. 62
Author(s):  
Sofia Stromeyer ◽  
Daniel Wiedemeier ◽  
Albert Mehl ◽  
Andreas Ender

The purpose of this in vitro study was to compare the time efficiency of digital chairside and labside workflows with a conventional workflow for single-unit restorations. The time efficiency in this specific sense was defined as the time, which has to be spent in a dental office by a dental professional performing the relevant steps. A model with interchangeable teeth on position 36 was created. These teeth were differently prepared, responding to several clinical situations to perform single-unit restorations. Different manufacturing techniques were used: For the digital workflows, CEREC Omnicam (CER) and Trios 3 (TN/TI) were used. The conventional workflow, using a dual-arch tray impression technique, served as the control group. For the labside workflow (_L) and the conventional impression procedure (CO), the time necessary for the impressions and temporary restorations was recorded and served as operating time. The chairside workflow time was divided by the time for the entire workflow (_C) including scan, design, milling and finishing the milled restoration, and in the actual working time (_CW) leaving out the chairside milling of the restoration. Labside workflow time ranged from 9 min 27 s (CER_L) to 12 min 41 s (TI_L). Entire chairside time ranged from 43 min 35 s (CER_C) to 58 min 43 s (TI_C). Pure chairside working time ranged from 15 min 21 s (CER_CW) to 23 min 17 s (TI_CW). Conventional workflow time was 10 min 39 s (CO) on average. The digital labside workflow and the conventional workflow require a similar amount of time. The digital chairside workflow is more time consuming.


2018 ◽  
Vol 6 (9) ◽  
pp. 1707-1711
Author(s):  
Rami M. Atia ◽  
Nada Omar ◽  
Haidy Nabil ◽  
Yousra Aly

OBJECTIVE: The aim of this in vitro study was to assess the effect of obturation technique and cementation timings on the bonding of fibre-reinforced posts to the root canal walls. METHODS: Twenty extracted teeth were randomly allocated to two groups according to the obturation technique and cementation timing. Central incisors with single canals were used after being decoronated. Every extracted tooth of the {vertical compaction group} (VC) group (n = 10) had been obturated using the {E & Q plus obturation system} with posts cemented in the same day; The other (CO) conventional group (n = 10) teeth were obturated using the conventional lateral compaction technique and posts cemented after one week. “SF“ Fiber posts were used after bonding and cementation using Rely X ARC resin cement with all the endodontically treated teeth. The push-out test was performed in a universal testing machine. Data were analysed by 2 way analysis of variance with Statistical significance was set to 0.05. RESULTS: Heat softened gutta percha group showed more push out the bond strength of the bonded posts than the conventional obturation group (p < 0.05). In the middle region, there was no statistical significance between the two groups while there was significance in the coronal and apical thirds. CONCLUSION: The vertical compaction technique and early cementation improved the bond strength of the resin posts in comparison to the conventional obturation technique with late cementation.


2019 ◽  
Vol 3 (9) ◽  
pp. 283-289
Author(s):  
Shuchi Sukul ◽  
Goldy Rathee ◽  
Parimal Anand ◽  
Sakshi Kataria ◽  
Pratibha Taneja

OBJECTIVES: The present research was conducted to assess incidences of root microcracks caused by hand and rotary file system at different lengths MATERIAL AND METHODS: This in-vitro study was undertaken to assess incidence of root microcracks caused by hand and rotary file system at different lengths In total, 100 the mandibular premolar with straight roots determined with intact, fully formed apices were taken. Samples were randomly distributed into 5 groups based on the file system used: a) Group A: Control, b) Group B: Reciproc, c) Group C: WaveOne, d) Group D: One Shape and e) Group E: ProTaper. Pearson Chi-square test was used to determine the differences between groups. The dentinal defects were expressed as percentage of samples with microcracks in each group. Level of statistical significance was set at p-value less than 0.05. RESULTS: The chi square test was used to compare the Distribution of the number of teeth in which cracks were observed on the horizontal sections. It was found to be significant with group ProTaper showing maximum cracks at 3,6,9 mm level as compared to other file systemCONCLUSION: Nickel-titanium instruments causes cracks on the apical root surface or in the root canal wall. ProTaper causes maximum dentinal cracks as compared to other file systems


2020 ◽  
Vol 45 (1) ◽  
pp. 62-70
Author(s):  
C Dettwiler ◽  
F Eggmann ◽  
L Matthisson ◽  
C Meller ◽  
R Weiger ◽  
...  

SUMMARY Aim: The aim of this study was to quantitatively compare conventional composite removal and composite removal supported by the fluorescence-aided identification technique (FIT) regarding the completeness, selectivity, and duration of the procedure in directly restored permanent posterior teeth. Methods and Materials: Two operators removed standardized direct class II composite restorations (n=32 per operator) in human tooth models under simulated clinical conditions. According to a randomized allocation scheme, removal was performed with either the conventional technique (contra-angle handpiece) or supported by FIT. The duration of each removal procedure was recorded. The completeness and selectivity were volumetrically assessed through superimposition of three-dimensional surface scans. Statistical significance was tested by examining the overlap of 95% confidence intervals (CI). Multiple comparison was performed with Tukey tests for each variable. Results: Compared with the conventional technique, composite removal with FIT was faster (329 seconds [95% confidence interval (CI): 268-390 seconds] vs 179 seconds [95% CI: 150-208 seconds]), generated less tooth substance loss (4.53 mm3 [95% CI: 3.77-5.30 mm3] vs 2.77 mm3 [95% CI: 2.11-3.43 mm3]), and left behind less composite residue (1.58 mm3 [95% CI: 1.23-1.94 mm3] vs 0.53 mm3 [95% CI: 0.39-0.67 mm3]). Conclusion: Within the limitations of this in vitro study, FIT facilitated the selective and expeditious removal of tooth-colored composites in directly restored posterior teeth.


2020 ◽  
Vol 10 (8) ◽  
pp. 2741 ◽  
Author(s):  
Young Hyun Kim ◽  
Sang-Sun Han ◽  
Yoon Joo Choi ◽  
Chang-Woo Woo

Improving the accuracy of the digital model is essential for the digitalization of the dental field. This study introduced a novel method of objective accuracy evaluation of digitized full dental arch model using coordinate measuring machine (CMM). To obtain a true linear measurement value using the CMM, 17 reference balls were attached to the typodont, and 12 measurements between balls on the X-(width), Y-(length), and Z-axes (height) were performed automatically. A rubber impression and a plaster cast replica of the typodont with balls were fabricated, and they were digitized with following methods: (a) true model intraoral scans; (b) impression cone-beam computed tomography (CBCT) scans; (c) cast CBCT scans; and (d) cast extraoral scans. Each scanning method was performed 20 times. Twelve linear measurements on the digitized models were automatically made using software. The one-sample t-test and one-way analysis of variance were used for measurement accuracy analysis. The cast extraoral scan was most accurate on X- and Y-axes, while impression CBCT was the most accurate on Z-axis. Over all axes, the intraoral scan resulted in the most deviation from the true model, and the reproducibility of each scan was also low. Extraoral scan shows high precision on width and length, and impression CBCT is advantageous for dental work where height factor is of importance.


Sign in / Sign up

Export Citation Format

Share Document