scholarly journals Modern Approaches and Innovations on Methods and Imaging Protocols of the Maxillofacial District

2021 ◽  
Vol 5 (1) ◽  
pp. 2
Author(s):  
Rodolfo Reda ◽  
Maurilio D’Angelo ◽  
Alessio Zanza ◽  
Dario Di Nardo ◽  
Luca Testarelli

In recent years, improvements in imaging techniques have profoundly changed the diagnosis of pathologies of the maxillofacial district [...]

2004 ◽  
Vol 18 (2) ◽  
pp. 80-87 ◽  
Author(s):  
Archie Heddings ◽  
Mehmet Bilgen ◽  
Randolph Nudo ◽  
Bruce Toby ◽  
Terence McIff ◽  
...  

Objectives. It is widely accepted that peripheral nerve repairs performed within 6 weeks of injury have much better outcomes than those performed at later dates. However, there is no diagnostic technique that can determine if a traumatic peripheral nerve injury requires surgical intervention in the early postinjury phase. The objective of this article was to determine whether novel, noninvasive magnetic resonance imaging techniques could demonstrate the microstructure of human peripheral nerves that is necessary for determining prognosis and determining if surgery is indicated following traumatic injury. Methods. Ex vivo magnetic resonance imaging protocols were developed on a 9.4-T research scanner using spin-echo proton density and gradient-echo imaging sequences and a specially designed, inductively coupled radio frequency coil. These imaging protocols were applied to in situ imaging of the human median nerve in 4 fresh-frozen cadaver arms. Results. Noninvasive high-resolution images of the human median nerve were obtained. Structures in the nerve that were observed included fascicles, interfascicular epineurium, perineurium, and intrafascicular septations. Conclusion. Application of these imaging techniques to clinical scanners could provide physicians with a tool that is capable of grading the severity of nerve injuries and providing indications for surgery in the early postinjury phase.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Susan C. Shelmerdine ◽  
J. Ciaran Hutchinson ◽  
Celine Lewis ◽  
Ian C. Simcock ◽  
Thivya Sekar ◽  
...  

AbstractPost-mortem imaging has a high acceptance rate amongst parents and healthcare professionals as a non-invasive method for investigating perinatal deaths. Previously viewed as a ‘niche’ subspecialty, it is becoming increasingly requested, with general radiologists now more frequently asked to oversee and advise on appropriate imaging protocols. Much of the current literature to date has focussed on diagnostic accuracy and clinical experiences of individual centres and their imaging techniques (e.g. post-mortem CT, MRI, ultrasound and micro-CT), and pragmatic, evidence-based guidance for how to approach such referrals in real-world practice is lacking. In this review, we summarise the latest research and provide an approach and flowchart to aid decision-making for perinatal post-mortem imaging. We highlight key aspects of the maternal and antenatal history that radiologists should consider when protocolling studies (e.g. antenatal imaging findings and history), and emphasise important factors that could impact the diagnostic quality of post-mortem imaging examinations (e.g. post-mortem weight and time interval). Considerations regarding when ancillary post-mortem image-guided biopsy tests are beneficial are also addressed, and we provide key references for imaging protocols for a variety of cross-sectional imaging modalities.


2020 ◽  
Vol 62 (1) ◽  
pp. 58-66
Author(s):  
Hiroyuki Okamoto ◽  
Satoshi Kito ◽  
Naoki Tohyama ◽  
Shunsuke Yonai ◽  
Ryu Kawamorita ◽  
...  

Abstract Institutional imaging protocols for the verification of brachytherapy applicator placements were investigated in a survey study of domestic radiotherapy institutions. The survey form designed by a free on-line survey system was distributed via the mailing-list system of the Japanese Society for Radiation Oncology. Survey data of 75 institutions between August 2019 and October 2019 were collected. The imaging modalities used were dependent on resources available to the institutions. The displacement of a brachytherapy applicator results in significant dosimetric impact. It is essential to verify applicator placements using imaging modalities before treatment. Various imaging modalities used in institutions included a computed tomography (CT) scanner, an angiography X-ray system, a multi-purpose X-ray system and a radiotherapy simulator. The median total exposure time in overall treatment sessions was $\le$75 s for gynecological and prostate cancers. Some institutions used fluoroscopy to monitor the brachytherapy source movement. Institutional countermeasures for reducing unwanted imaging dose included minimizing the image area, changing the imaging orientation, reducing the imaging frequency and optimizing the imaging conditions. It is worth noting that half of the institutions did not confirm imaging dose regularly. This study reported on the usage of imaging modalities for brachytherapy in Japan. More caution should be applied with interstitial brachytherapy with many catheters that can lead to potentially substantial increments in imaging doses for monitoring the actual brachytherapy source using fluoroscopy. It is necessary to share imaging techniques, standardize imaging protocols and quality assurance/quality control among institutions, and imaging dose guidelines for optimization of imaging doses delivered in radiotherapy should be developed.


Author(s):  
Jerome J. Paulin

Within the past decade it has become apparent that HVEM offers the biologist a means to explore the three-dimensional structure of cells and/or organelles. Stereo-imaging of thick sections (e.g. 0.25-10 μm) not only reveals anatomical features of cellular components, but also reduces errors of interpretation associated with overlap of structures seen in thick sections. Concomitant with stereo-imaging techniques conventional serial Sectioning methods developed with thin sections have been adopted to serial thick sections (≥ 0.25 μm). Three-dimensional reconstructions of the chondriome of several species of trypanosomatid flagellates have been made from tracings of mitochondrial profiles on cellulose acetate sheets. The sheets are flooded with acetone, gluing them together, and the model sawed from the composite and redrawn.The extensive mitochondrial reticulum can be seen in consecutive thick sections of (0.25 μm thick) Crithidia fasciculata (Figs. 1-2). Profiles of the mitochondrion are distinguishable from the anterior apex of the cell (small arrow, Fig. 1) to the posterior pole (small arrow, Fig. 2).


Author(s):  
S. R. Herd ◽  
P. Chaudhari

Electron diffraction and direct transmission have been used extensively to study the local atomic arrangement in amorphous solids and in particular Ge. Nearest neighbor distances had been calculated from E.D. profiles and the results have been interpreted in terms of the microcrystalline or the random network models. Direct transmission electron microscopy appears the most direct and accurate method to resolve this issue since the spacial resolution of the better instruments are of the order of 3Å. In particular the tilted beam interference method is used regularly to show fringes corresponding to 1.5 to 3Å lattice planes in crystals as resolution tests.


Author(s):  
Shawn Williams ◽  
Xiaodong Zhang ◽  
Susan Lamm ◽  
Jack Van’t Hof

The Scanning Transmission X-ray Microscope (STXM) is well suited for investigating metaphase chromosome structure. The absorption cross-section of soft x-rays having energies between the carbon and oxygen K edges (284 - 531 eV) is 6 - 9.5 times greater for organic specimens than for water, which permits one to examine unstained, wet biological specimens with resolution superior to that attainable using visible light. The attenuation length of the x-rays is suitable for imaging micron thick specimens without sectioning. This large difference in cross-section yields good specimen contrast, so that fewer soft x-rays than electrons are required to image wet biological specimens at a given resolution. But most imaging techniques delivering better resolution than visible light produce radiation damage. Soft x-rays are known to be very effective in damaging biological specimens. The STXM is constructed to minimize specimen dose, but it is important to measure the actual damage induced as a function of dose in order to determine the dose range within which radiation damage does not compromise image quality.


Author(s):  
D. A. Carpenter ◽  
M. A. Taylor

The development of intense sources of x rays has led to renewed interest in the use of microbeams of x rays in x-ray fluorescence analysis. Sparks pointed out that the use of x rays as a probe offered the advantages of high sensitivity, low detection limits, low beam damage, and large penetration depths with minimal specimen preparation or perturbation. In addition, the option of air operation provided special advantages for examination of hydrated systems or for nondestructive microanalysis of large specimens.The disadvantages of synchrotron sources prompted the development of laboratory-based instrumentation with various schemes to maximize the beam flux while maintaining small point-to-point resolution. Nichols and Ryon developed a microprobe using a rotating anode source and a modified microdiffractometer. Cross and Wherry showed that by close-coupling the x-ray source, specimen, and detector, good intensities could be obtained for beam sizes between 30 and 100μm. More importantly, both groups combined specimen scanning with modern imaging techniques for rapid element mapping.


Author(s):  
R.T. Chen ◽  
M.G. Jamieson ◽  
R. Callahan

“Row lamellar” structures have previously been observed when highly crystalline polymers are melt-extruded and recrystallized under high stress. With annealing to perfect the stacked lamellar superstructure and subsequent stretching in the machine (extrusion) direction, slit-like micropores form between the stacked lamellae. This process has been adopted to produce polymeric membranes on a commercial scale with controlled microporous structures. In order to produce the desired pore morphology, row lamellar structures must be established in the membrane precursors, i.e., as-extruded and annealed polymer films or hollow fibers. Due to the lack of pronounced surface topography, the lamellar structures have typically been investigated by replica-TEM, an indirect and time consuming procedure. Recently, with the availability of high resolution imaging techniques such as scanning tunneling microscopy (STM) and field emission scanning electron microscopy (FESEM), the microporous structures on the membrane surface as well as lamellar structures in the precursors can be directly examined.The materials investigated are Celgard® polyethylene (PE) flat sheet membranes and their film precursors, both as-extruded and annealed, made at different extrusion rates (E.R.).


Author(s):  
James Pawley ◽  
David Joy

The scanning electron microscope (SEM) builds up an image by sampling contiguous sub-volumes near the surface of the specimen. A fine electron beam selectively excites each sub-volume and then the intensity of some resulting signal is measured and then plotted as a corresponding intensity in an image. The spatial resolution of such an image is limited by at least three factors. Two of these determine the size of the interaction volume: the size of the electron probe and the extent to which detectable signal is excited from locations remote from the beam impact area. A third limitation emerges from the fact that the probing beam is composed of a number of discrete particles and therefore that the accuracy with which any detectable signal can be measured is limited by Poisson statistics applied to this number (or to the number of events actually detected if this is smaller). As in all imaging techniques, the limiting signal contrast required to recognize a morphological structure is constrained by this statistical consideration. The only way to overcome this limit is to increase either the contrast of the measured signal or the number of beam/specimen interactions detected. Unfortunately, these interactions deposit ionizing radiation that may damage the very structure under investigation. As a result, any practical consideration of the high resolution performance of the SEM must consider not only the size of the interaction volume but also the contrast available from the signal producing the image and the radiation sensitivity of the specimen.


Author(s):  
P.A. Crozier ◽  
M. Pan

Heterogeneous catalysts can be of varying complexity ranging from single or double phase systems to complicated mixtures of metals and oxides with additives to help promote chemical reactions, extend the life of the catalysts, prevent poisoning etc. Although catalysis occurs on the surface of most systems, detailed descriptions of the microstructure and chemistry of catalysts can be helpful for developing an understanding of the mechanism by which a catalyst facilitates a reaction. Recent years have seen continued development and improvement of various TEM, STEM and AEM techniques for yielding information on the structure and chemistry of catalysts on the nanometer scale. Here we review some quantitative approaches to catalyst characterization that have resulted from new developments in instrumentation.HREM has been used to examine structural features of catalysts often by employing profile imaging techniques to study atomic details on the surface. Digital recording techniques employing slow-scan CCD cameras have facilitated the use of low-dose imaging in zeolite structure analysis and electron crystallography. Fig. la shows a low-dose image from SSZ-33 zeolite revealing the presence of a stacking fault.


Sign in / Sign up

Export Citation Format

Share Document