scholarly journals Experimental Evaluation of Axial Reaction Turbine Stage Bucket Losses

Processes ◽  
2021 ◽  
Vol 9 (10) ◽  
pp. 1816
Author(s):  
Marek Klimko ◽  
Richard Lenhard ◽  
Pavel Žitek ◽  
Katarína Kaduchová

The article describes the measurement methods and data evaluation from a single-stage axial turbine with high reaction (50%). Four operating modes of the turbine were selected, in which the wake traversing behind nozzle and bucket with five-hole pneumatic probes took place. The article further focuses on the evaluation of bucket losses for all four measured operating modes, including the analysis of measurement uncertainties.

Author(s):  
Nicholas Anton ◽  
Magnus Genrup ◽  
Carl Fredriksson ◽  
Per-Inge Larsson ◽  
Anders Christiansen-Erlandsson

In the process of evaluating a parallel twin-turbine pulse-turbocharged concept, the results considering the turbine operation clearly pointed towards an axial type of turbine. The radial turbine design first analyzed was seen to suffer from sub-optimum values of flow coefficient, stage loading and blade-speed-ratio. Modifying the radial turbine by both assessing the influence of “trim” and inlet tip diameter all concluded that this type of turbine is limited for the concept. Mainly, the turbine stage was experiencing high values of flow coefficient, requiring a more high flowing type of turbine. Therefore, an axial turbine stage could be feasible as this type of turbine can handle significantly higher flow rates very efficiently. Also, the design spectrum is broader as the shape of the turbine blades is not restricted by a radially fibred geometry as in the radial turbine case. In this paper, a single stage axial turbine design is presented. As most turbocharger concepts for automotive and heavy-duty applications are dominated by radial turbines, the axial turbine is an interesting option to be evaluated for pulse-charged concepts. Values of crank-angle-resolved turbine and flow parameters from engine simulations are used as input to the design and subsequent analysis. The data provides a valuable insight into the fluctuating turbine operating conditions and is a necessity for matching a pulse-turbocharged system. Starting on a 1D-basis, the design process is followed through, resulting in a fully defined 3D-geometry. The 3D-design is evaluated both with respect to FEA and CFD as to confirm high performance and durability. Turbine maps were used as input to the engine simulation in order to assess this design with respect to “on-engine” conditions and to engine performance. The axial design shows clear advantages with regards to turbine parameters, efficiency and tip speed levels compared to a reference radial design. Improvement in turbine efficiency enhanced the engine performance significantly. The study concludes that the proposed single stage axial turbine stage design is viable for a pulse-turbocharged six-cylinder heavy-duty engine. Taking into account both turbine performance and durability aspects, validation in engine simulations, a highly efficient engine with a practical and realizable turbocharger concept resulted.


2011 ◽  
Vol 134 (4) ◽  
Author(s):  
Jing-Lun Fu ◽  
Jian-Jun Liu ◽  
Si-Jing Zhou

The exhaust system in condensing steam turbines is used to recover leaving kinetic energy of the last stage turbine, while guiding the flow from turbine to condenser. The flows in the exhaust system and the turbine stage are fully coupled and inherently unsteady. The unsteady flow interactions between the turbine and the exhaust system have a strong impact on the blade loading or blade aerodynamic force. This paper describes the unsteady flow interactions between a single-stage axial turbine and an exhaust system. The experimental and numerical studies on the coupled flow field in the single-stage turbine and the exhaust hood model under different operational conditions have been carried out. Unsteady pressure at the turbine rotor blade, turbine outlet, and exhaust outcasing are measured and compared with the numerical prediction. The details of unsteady flow in the exhaust system with the whole annulus stator and rotor blade rows are simulated by employing the computational fluid dynamics software CFX-5. Results show that for the investigated turbine-exhaust configuration the influence of the flow field in the exhaust system on the unsteady blade force is much stronger than that of the stator and rotor interaction. The flow pattern in the exhaust system changes with the turbine operational condition, which influences the unsteady flow in the turbine stage further.


2020 ◽  
Vol 328 ◽  
pp. 03013
Author(s):  
Marek Klimko ◽  
Pavel Žitek ◽  
Richard Lenhard

This article describes a measuring methods and evaluating measured data on a single-stage axial turbine with reaction (~ 50 %). One turbine operating mode was selected, in which the traversing behind the nozzle and bucket with two 5-hole pneumatic probes took place. The results are distributions of flow angles, reactions, or losses distribution/efficiencies along the blades.


Author(s):  
Prathapanayaka Rajeevalochanam ◽  
S. N. Agnimitra Sunkara ◽  
Balamurugan Mayandi ◽  
Bala Venkata Ganesh Banda ◽  
Veera Sesha Kumar Chappati ◽  
...  

Aero-thermodynamic and mechanical design of a single stage axial turbine stage has been carried out for small gas turbine engine in Propulsion Division, CSIR-NAL. From the engine design configuration extract, it is envisaged that the single stage axial gas turbine operating close to 50500 rpm and at an elevated temperature of 1095K would meet the power requirement of mixed flow compressor of 385kW. This paper presents the aero-thermodynamic, mechanical design and analysis of a single stage highly loaded axial turbine stage with a stage loading coefficient of 1.45 and a flow coefficient of 0.67. The mean-line and detailed 3D aero-thermodynamic design is carried out using commercially available dedicated turbomachinery design codes Axial® and Axcent™ of Concepts NREC. The number of blades of the rotor and stator are 50 & 19 respectively. The turbine stage has undergone a series of design improvements. The final configuration of single stage turbine is analyzed using commercially available RANS CFD software ANSYS-CFX™ and NUMECAFINE™/Turbo flow solver. The design is carried out by aiming 88% total-to-total efficiency. Detailed 3D-RANS CFD analysis of the turbine shows that, the design requirements of turbine are achieved with enhanced efficiency of 90%. Mechanical design & analysis of the turbine stage is carried out using ANSYS-Mechanical™ software. Nimonic-90 material is selected for fabrication. Detailed non-linear steady thermal-structural analysis is carried out for both stator assembly and rotor BLISK. Burst margin of rotor disk is estimated to be around 63% at design speed.


Author(s):  
Hafiz M Hassan ◽  
Adeel Javed ◽  
Asif H Khoja ◽  
Majid Ali ◽  
Muhammad B Sajid

A clear understanding of the flow characteristics in the older generation of industrial gas turbines operating with silo combustors is important for potential upgrades. Non-uniformities in the form of circumferential and radial variations in internal flow properties can have a significant impact on the gas turbine stage performance and durability. This paper presents a comprehensive study of the underlying internal flow features involved in the advent of non-uniformities from twin-silo combustors and their propagation through a single axial turbine stage of the Siemens v94.2 industrial gas turbine. Results indicate the formation of strong vortical structures alongside large temperature, pressure, velocity, and flow angle deviations that are mostly located in the top and bottom sections of the turbine stage caused by the excessive flow turning in the upstream tandem silo combustors. A favorable validation of the simulated exhaust gas temperature (EGT) profile is also achieved via comparison with the measured data. A drop in isentropic efficiency and power output equivalent to 2.28% points and 2.1 MW, respectively is observed at baseload compared to an ideal straight hot gas path reference case. Furthermore, the analysis of internal flow topography identifies the underperforming turbine blading due to the upstream non-uniformities. The findings not only have implications for the turbine aerothermodynamic design, but also the combustor layout from a repowering perspective.


2021 ◽  
Vol 1843 (1) ◽  
pp. 012017
Author(s):  
V A Kalytka ◽  
M V Korovkin ◽  
P Sh Madi ◽  
A D Mekhtiyev ◽  
A V Bashirov ◽  
...  

Author(s):  
Kurt Weber ◽  
Girish Modgil ◽  
Steve Gegg ◽  
Shyam Neerarambam ◽  
Moujin Zhang

The flow field in High-Work Single-Stage (HWSS) turbines differs from traditional turbine flow fields. Operating at increased pressure ratios, wakes and trailing edge shocks at the exit of the vane are more likely to cause a vibratory response in the rotating blade. This flow field can produce increased excitation at harmonics that correspond to the vane passing frequency and harmonics higher than the vane passing frequency. In this paper, blade vibratory stresses in a HWSS gas turbine stage are predicted using unsteady pressures from two Rolls-Royce in-house flow codes that employ different phase lagged unsteady approaches. Hydra uses a harmonic storage approach, and the Vane/Blade Interaction (VBI) code uses a direct storage approach. Harmonic storage reduces memory requirements considerably. The predicted stress for four modes at two engine speeds are presented and are compared with rig test strain gauge data to assess and validate the predictive capability of the codes for forced response. Strain gauge data showed the need to consider harmonics higher than the fundamental vane passing frequency for the max power shaft speed and operating at the conditions. Because of this, it was a good case for validation and for comparing the two codes. Overall, it was found that, stress predictions using the Hydra flow code compare better with data. To the best of the authors’ knowledge, this paper is a first in comparing two different phase lagged unsteady approaches, in the context of forced response, to engine rig data for a High-Work Single Stage turbine.


Author(s):  
Tobias R. Müller ◽  
Damian M. Vogt ◽  
Klemens Vogel ◽  
Bent A. Phillipsen ◽  
Peter Hönisch

The effects of detailing on the prediction of forced-response in a transonic axial turbine stage, featuring a parted stator design, asymmetric inlet and outlet casings as well as rotor cavities, is investigated. Ensuring the mechanical integrity of components is of paramount importance for the safe and reliable operation of turbomachines. Among others, flow induced resonance excitation can lead to high-cycle fatigue (HCF) and potentially to damage of components unless properly damped. This numerical study is assessing the necessary degree of detailing in terms of spatial and temporal discretization, boundary conditions of the pre-stressed rotor geometry as well as geometrical detailing for the reliable prediction of the aerodynamic excitation of the structure. In this context, the sensitivity of the aerodynamic forcing is analyzed by means of the generalized force criterion, showing a significant influence for some of the investigated variations of the numerical model. Moreover, the origin and further progression of several low-engine-orders (LEO) within the flow field, as well as their interaction with different geometric details has been analyzed based on the numerical results obtained from a full 360° CFD-calculation of the investigated turbine stage. The predicted flow induced vibration of the structure has been validated by means of a full forced-response analysis, where a good agreement with tip-timing data has been found.


Author(s):  
K. Asgar Ali ◽  
Quamber H. Nagpurwala ◽  
Abdul Nassar ◽  
S. V. Ramanamurthy

This paper deals with the numerical investigations on a low pressure axial turbine stage to assess the effect of variation in rotor tip clearance and tip coolant ejection rate on the end wall losses. The rotor, along with the NGV, was modeled to represent the entire turbine stage. The CFX TASCflow software was used to perform steady state analysis for different rotor tip clearances and different tip coolant ejection rates. The locations of the cooling slots were identified on the blade tip and the coolant ejection rate was specified at these areas. The simulations were carried out with tip clearances of 0%, 1% and 2% of blade height and ejection flow rates of 0.5%, 0.75% and 1% of main turbine flow rate. It is shown that the size and strength of the leakage vortex is directly related to the tip clearance. The reduction in efficiency is not in linearity with the tip clearance owing to the effect of boundary layer growth on the end walls. Introduction of the tip coolant flow shows increased total–total efficiency compared to that of the uncooled tip. This is attributed to a reduction in the strength of the leakage vortex due to reduced cross-flow over the tip clearance from pressure surface to suction surface. At a coolant flow rate of 0.75% of the main flow rate, there is significant increase in efficiency of about 0.5%. Optimum tip clearance and coolant flow rate are obtained based on the results of the present analysis.


Sign in / Sign up

Export Citation Format

Share Document