Numerical investigation of non-uniform flow in twin-silo combustors and impact on axial turbine stage performance

Author(s):  
Hafiz M Hassan ◽  
Adeel Javed ◽  
Asif H Khoja ◽  
Majid Ali ◽  
Muhammad B Sajid

A clear understanding of the flow characteristics in the older generation of industrial gas turbines operating with silo combustors is important for potential upgrades. Non-uniformities in the form of circumferential and radial variations in internal flow properties can have a significant impact on the gas turbine stage performance and durability. This paper presents a comprehensive study of the underlying internal flow features involved in the advent of non-uniformities from twin-silo combustors and their propagation through a single axial turbine stage of the Siemens v94.2 industrial gas turbine. Results indicate the formation of strong vortical structures alongside large temperature, pressure, velocity, and flow angle deviations that are mostly located in the top and bottom sections of the turbine stage caused by the excessive flow turning in the upstream tandem silo combustors. A favorable validation of the simulated exhaust gas temperature (EGT) profile is also achieved via comparison with the measured data. A drop in isentropic efficiency and power output equivalent to 2.28% points and 2.1 MW, respectively is observed at baseload compared to an ideal straight hot gas path reference case. Furthermore, the analysis of internal flow topography identifies the underperforming turbine blading due to the upstream non-uniformities. The findings not only have implications for the turbine aerothermodynamic design, but also the combustor layout from a repowering perspective.

Author(s):  
Thomas Palmé ◽  
Francois Liard ◽  
Dirk Therkorn

Failures in the gas path of a Gas Turbine will cause a deviation in the measured performance parameters. One of the most important parameters is the Turbine Exit Temperature (TET) and refers to the hot gas temperature at the exhaust of a Gas Turbine (GT). However, TET is not uniform at the turbine outlet and the temperature is therefore sometimes measured at several axial and radial positions. The TET has what can be considered a natural variation, an effect of operation in different ambient and operational conditions which influences the internal flow field. It can be informative on the health status of the GT by monitoring the TET variation during operation, as a number of failures or abnormal operation conditions will affect the TET distribution. A regular way of monitoring the TET is to use the average value from different sensor readings, or compare the highest deviating sensor to the average value of all sensors. However in order to detect anomalies as early as possible deviations from the healthy profile should be detected more finely across the section. In this paper, a data-driven similarity based algorithm called Auto Associative Kernel Regression is applied to the issue of monitoring the TET spread variation on an industrial gas turbine. A case study is supplied to show the practical usefulness of the algorithm to a field failure.


Author(s):  
Kazuo Takeya ◽  
Hajime Yasui

In 1978, the Japanese government started a national project for energy conservation called the Moonlight Project. The Engineering Research Association for Advanced Gas Turbines was selected to research and develop an advanced gas turbine for this project. The development stages were planned as follows: First, the development of a reheat gas turbine for a pilot plant (AGTJ-100A), and second, a prototype plant (AGTJ-100B). The AGTJ-100A has been undergoing performance tests since 1984 at the Sodegaura Power Station of the Tokyo Electric Power Co., Inc. (TEPCO). The inlet gas temperature of the high pressure turbine (HPT) of the AGTJ-100A is 1573K, while that of the AGTJ-100B is 100K higher. Therefore, various advanced technologies have to be applied to the AGTJ-100B HPT. Ceramic coating on the HPT blades is the most desirable of these technologies. In this paper, the present situation of development, as well as future R & D plans for ceramic coating, is taken into consideration. Steam blade cooling is applied for the IGSC.


Author(s):  
SS Talebi ◽  
AM Tousi ◽  
A Madadi ◽  
M Kiaee

Recently, the utilization of micro gas turbines in smart grids are rising that makes the part-load operation principal situation of the engine service. This leads to faster life consumption that increases the importance of the diagnostics process. Gas path analysis is an effective method for gas turbine diagnostics. Complex dynamics of gas turbine induces challenging conditions to perform applicable gas path analysis. This study aims to facilitate MGT gas path diagnostics through reducing the number of monitoring parameters and preparation a pattern for engine level and component level health assessment in both full and part load operation of a recuperated micro gas turbine. To attain this goal a model is proposed to simulate MGT off-design performance which is validated against experimental data in healthy and degraded operation modes. Fouling in compressor, turbine and recuperator and erosion in compressor and turbine as the most common degradations in the gas turbine are considered. The fault simulation is performed by changing the health parameters of gas path components. According to the result investigation, a matrix comprises deviation contours of four parameters, Power, fuel flow, compressor discharge pressure, and exhaust gas temperature is presented and analyzed. The analysis shows that monitoring these parameters makes it possible to perform engine level and component level diagnostics through evaluating a binary code (generated by mentioned parameter variations) against the fault effects pattern in different load fractions and fault severities. The simulation also showed that the most power drop occurred under the compressor fouling by about 8.7% while the most reduction in thermal efficiency is observed under recuperator fouling by about 7.84%. Furthermore, the investigation showed the maximum decrease in the surge margin induced by the compressor fouling during the lower part-load operation by about 45.7% while in the higher loads created by the turbine fouling by about 14%.


2021 ◽  
Author(s):  
Takashi Nishiumi ◽  
Hirofumi Ohara ◽  
Kotaro Miyauchi ◽  
Sosuke Nakamura ◽  
Toshishige Ai ◽  
...  

Abstract In recent years, MHPS achieved a NET M501J gas turbine combined cycle (GTCC) efficiency in excess of 62% operating at 1,600°C, while maintaining NOx under 25ppm. Taking advantage of our gas turbine combustion design, development and operational experience, retrofits of earlier generation gas turbines have been successfully applied and will be described in this paper. One example of the latest J-Series technologies, a conventional pilot nozzle was changed to a premix type pilot nozzle for low emission. The technology was retrofitted to the existing F-Series gas turbines, which resulted in emission rates of lower than 9ppm NOx(15%O2) while maintaining the same Turbine Inlet Temperature (TIT: Average Gas Temperature at the exit of the transition piece). After performing retrofitting design, high pressure rig tests, the field test prior to commercial operation was conducted on January 2019. This paper describes the Ultra-Low NOx combustor design features, retrofit design, high pressure rig test and verification test results of the upgraded M501F gas turbine. In addition, it describes another upgrade of turbine to improve efficiency and of combustion control system to achieve low emissions. Furthermore it describes the trouble-free upgrade of seven (7) units, which was completed by utilizing MHPS integration capabilities, including handling all the design, construction and service work of the main equipment, plant and control systems.


Author(s):  
Liu Jinfu ◽  
Liu Jiao ◽  
Wan Jie ◽  
Wang Zhongqi ◽  
Yu Daren

The working environment of hot components is the most adverse of all gas turbine components. Malfunction of hot components is often followed by catastrophic consequences. Early fault detection plays a significant role in detecting performance deterioration immediately and reducing unscheduled maintenance. In this paper, an early fault detection method is introduced to detect early fault symptoms of hot components in gas turbines. The exhaust gas temperature (EGT) is usually used to monitor the performance of the hot components. The EGT is measured by several thermocouples distributed equally at the outlet of the gas turbine. EGT profile is symmetrical when the unit is in normal operation. And the faults of hot components lead to large temperature differences between different thermocouple readings. However, interferences can potentially affect temperature differences, and sometimes, especially in the early stages of the fault, its influence can be even higher than that of the faults. To improve the detection sensitivity, the influence of interferences must be eliminated. The two main interferences investigated in this study are associated with the operating and ambient conditions, and the structure deviation of different combustion chambers caused by processing and installation errors. Based on the basic principles of gas turbines and Fisher discriminant analysis (FDA), a new detection indicator is presented that characterizes the intrinsic structure information of the hot components. Using this new indicator, the interferences involving the certainty and the uncertainty are suppressed and the sensitivity of early fault detection in gas turbine hot components is improved. The robustness and the sensitivity of the proposed method are verified by actual data from a Taurus 70 gas turbine produced by Solar Turbines.


Author(s):  
Martin von Hoyningen-Huene ◽  
Wolfram Frank ◽  
Alexander R. Jung

Unsteady stator-rotor interaction in gas turbines has been investigated experimentally and numerically for some years now. Most investigations determine the pressure fluctuations in the flow field as well as on the blades. So far, little attention has been paid to a detailed analysis of the blade pressure fluctuations. For further progress in turbine design, however, it is mandatory to better understand the underlying mechanisms. Therefore, computed space–time maps of static pressure are presented on both the stator vanes and the rotor blades for two test cases, viz the first and the last turbine stage of a modern heavy duty gas turbine. These pressure fluctuation charts are used to explain the interaction of potential interaction, wake-blade interaction, deterministic pressure fluctuations, and acoustic waveswith the instantaneous surface pressure on vanes and blades. Part I of this two-part paper refers to the same computations, focusing on the unsteady secondary now field in these stages. The investigations have been performed with the flow solver ITSM3D which allows for efficient simulations that simulate the real blade count ratio. Accounting for the true blade count ratio is essential to obtain the correct frequencies and amplitudes of the fluctuations.


Author(s):  
K. K. Botros ◽  
D. Sennhauser ◽  
L. Siarkowski

Concerns about the effects of greenhouse gas emissions on the Earth’s climate have lead to a considerable focus by the public and governments on the levels of emissions that are generated by industrial activities. In Canada, it has been recognized that gas transmission systems are rated second in overall CO2 production in the Natural Gas Industry (next to gas processing). Most of the gas transmission systems are powered by gas turbines at compressor stations resulting in significant CO2 emissions (at the rate of ∼ 6 kilo tonnes/ per MW-year). This can be reduced if the CO2 can be separated from the gas turbine exhaust stream and directed for reuse or sequestration. This paper presents results of techno-thermodynamic assessment of two power cycle adjustments to increase CO2 concentrations in the exhaust gas from turbines. The working fluid in the two semi-closed cycles are made rich in CO2, thus making it easy to capture the CO2 from the flue gas by means of physical absorption techniques rather than by the conventional expensive amine adsorption methods. Additionally, the CO2 rich working fluid is shown to give rise to a higher exhaust gas temperature from the gas turbine semi-closed cycles, allowing a steam bottom cycle to be effective in augmenting the power delivered by the entire system by 50%, hence contributing to reducing emission by increasing the overall thermal efficiency of the system.


Author(s):  
Ioanna Aslanidou ◽  
Budimir Rosic ◽  
Vasudevan Kanjirakkad ◽  
Sumiu Uchida

The remarkable developments in gas turbine materials and cooling technologies have allowed a steady increase in combustor outlet temperature and hence in gas turbine efficiency over the last half century. However, the efficiency benefits of higher gas temperature, even at the current levels, are significantly offset by the increased losses associated with the required cooling. Additionally, the advancements in gas turbine cooling technology have introduced considerable complexities into turbine design and manufacture. Therefore, a reduction in coolant requirements for the current gas temperature levels is one possible way for gas turbine designers to achieve even higher efficiency levels. The leading edges of the first turbine vane row are exposed to high heat loads. The high coolant requirements and geometry constraints limit the possible arrangement of the multiple rows of film cooling holes in the so called showerhead region. In the past, investigators have tested many different showerhead configurations, varying the number of rows, inclination angle and shape of the cooling holes. However the current leading edge cooling strategies using showerheads have not been shown to allow further increase in turbine temperature without excessive use of coolant air. Therefore new cooling strategies for the first vane have to be explored. In gas turbines with multiple combustor chambers around the annulus, the transition duct walls can be used to shield, i.e. to protect the first vane leading edges from the high heat loads. In this way the stagnation region at the leading edge and the shower-head of film cooling holes can be completely removed, resulting in a significant reduction in the total amount of cooling air that is otherwise required. By eliminating the showerhead the shielding concept significantly simplifies the design and lowers the manufacturing costs. This paper numerically analyses the potential of the leading edge shielding concept for cooling air reduction. The vane shape was modified to allow for the implementation of the concept and non-restrictive relative movement between the combustor and the vane. It has been demonstrated that the coolant flow that was originally used for cooling the combustor wall trailing edge and a fraction of the coolant air used for the vane showerhead cooling can be used to effectively cool both the suction and the pressure surfaces of the vane.


Author(s):  
R. Bhargava ◽  
M. Bianchi ◽  
G. Negri di Montenegro ◽  
A. Peretto

This paper presents a thermo-economic analysis of an intercooled, reheat (ICRH) gas turbine, with and without recuperation, for cogeneration applications. The optimization analyses of thermodynamic parameters have permitted to calculate variables, such as low-pressure compressor pressure ratio, high-pressure turbine pressure ratio and gas temperature at the waste heat recovery unit inlet while maximizing electric efficiency and “Energy Saving Index”. Subsequently, the economic analyses have allowed to evaluate return on the investment, and the minimum value of gross payout period, for the cycle configurations of highest thermodynamic performance. In the present study three sizes (100 MW, 20 MW and 5 MW) of gas turbines have been examined. The performed investigation reveals that the maximum value of electric efficiency and “Energy Saving Index” is achieved for a large size (100 MW) recuperated ICRH gas turbine based cogeneration system. However, a non-recuperated ICRH gas turbine (of 100 MW) based cogeneration system provides maximum value of return on the investment and the minimum value of gross payout period compared to the other gas turbine cycles, of the same size and with same power to heat ratio, investigated in the present study. A comprehensive thermo-economic analysis methodology, presented in this paper, should provide useful guidelines for preliminary sizing and selection of gas turbine cycle for cogeneration applications.


Author(s):  
Martin Aubé ◽  
Charles Hirsch

The analysis and design methods used for turbomachinery components are mostly based on steady aerodynamics, neglecting the important unsteady nature of the flow field. An improvement in performance can however be achieved with a prior understanding, evaluation and modeling of the main unsteady loss sources generated in rotor/stator interactions, through new advanced experimental data coupled to systematic and controlled numerical simulations performed at the full unsteady level of approximation. But such calculations are even nowadays challenges to the CFD community, due to their high requirement in computer resources. To investigate the importance of unsteady loss mechanisms, a 1-1/2 axial turbine stage has been resolved at both quasi-steady and fully unsteady levels of approximation. In order to reduce the demand on computer resources, a scaling procedure can be applied to retrieve equal pitch distance on both sides of each rotor/stator interface. The space and time flow periodicity are then uncoupled and the unsteady flowfield may be resolved on a reduced number of blade passages per row without having to consider any time periodicity in the boundary treatment. The grid scaling however affects the turbine total pressure ratio and the position and strength of secondary flows, as the pitch-to-chord ratio is not kept constant. This effect is analyzed in the paper, with the objective to assess the associated approximation errors. Steady and unsteady numerical simulations are compared with the experimental data along three measuring stations placed downstream of each blade row. Even if steady results are in good agreement and allow capturing the main flow structures of the turbine stage, only the fully unsteady calculation resolves the complex loss mechanisms encountered mainly in the rotor and downstream stator components. These unsteady interactions are observed through time variations of the entropy, absolute flow angle and static pressure.