scholarly journals Serial Ultrasonographic and Real-Time Elastosonographic Assessment of the Ovine Common Calcaneal Tendon, after an Experimentally Induced Tendinopathy

2021 ◽  
Vol 8 (4) ◽  
pp. 54
Author(s):  
Daniele Serrani ◽  
Antonella Volta ◽  
Franco Cingolani ◽  
Luca Pennasilico ◽  
Caterina Di Bella ◽  
...  

Real-time elastosonography (RTE) is a recently described, non-invasive, ultrasonographic technique developed to assess tissue elasticity. The main aim of this study was to investigate the ultrasonographic and elastosonographic appearance of the common calcaneal tendon (CCT) in an ovine model, and to monitor the progression of tendon healing after an experimentally-induced tendinopathy. Sound tendons were initially evaluated (T0) with a caliper and by a single operator with ultrasound. Ultrasonographic and elastosonographic images were then acquired. Subsequently, ultrasound-guided tendon lesions were induced by injecting 500 IU of Type IA collagenases proximally to the calcaneal tuberosity. Caliper measurement, ultrasonography and elastosonography were then repeated at 15 (T1), 30 (T2) and 60 (T3) days. Clinically measured width of the tendon, ultrasonographic thickness and width and percentage of hard (Elx-t%hrd) and soft (Elx-t%sft) tissue were recorded. Statistical analysis was performed on the data collected; statistical significance was set at p < 0.05. Intra-class correlation coefficient (ICC) revealed good (0.68) repeatability of elastosonographic evaluation of the CCT. The tendon width was significantly increased when comparing T0 with T1–2 and decreased when comparing T1–2 with T3. Ultrasound-assessed thickness was significantly increased between T0–T1 and decreased between T1-T2–3. Elx-t%hrd was significantly decreased at T1–2–3 and Elx-t%sft was significantly increased at T1–2–3. In conclusion, the ovine CCT is a highly stiff structure that undergoes a severe loss of stiffness during the healing process. Thickness and width of the tendon increased during the first 30 days and then reduced progressively along the subsequent 30 days. Ultrasonographic appearance of the tendon remained severely abnormal and the tendon showed severely reduced elastic proprieties 60 days after lesion induction.

2014 ◽  
Author(s):  
Rozaimi Ghazali ◽  
◽  
Asiah Mohd Pilus ◽  
Wan Mohd Bukhari Wan Daud ◽  
Mohd Juzaila Abd Latif ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1922
Author(s):  
Gwang Su Kim ◽  
Yumin Park ◽  
Joonchul Shin ◽  
Young Geun Song ◽  
Chong-Yun Kang

The breath gas analysis through gas phase chemical analysis draws attention in terms of non-invasive and real time monitoring. The array-type sensors are one of the diagnostic methods with high sensitivity and selectivity towards the target gases. Herein, we presented a 2 × 4 sensor array with a micro-heater and ceramic chip. The device is designed in a small size for portability, including the internal eight-channel sensor array. In2O3 NRs and WO3 NRs manufactured through the E-beam evaporator’s glancing angle method were used as sensing materials. Pt, Pd, and Au metal catalysts were decorated for each channel to enhance functionality. The sensor array was measured for the exhaled gas biomarkers CH3COCH3, NO2, and H2S to confirm the respiratory diagnostic performance. Through this operation, the theoretical detection limit was calculated as 1.48 ppb for CH3COCH3, 1.9 ppt for NO2, and 2.47 ppb for H2S. This excellent detection performance indicates that our sensor array detected the CH3COCH3, NO2, and H2S as biomarkers, applying to the breath gas analysis. Our results showed the high potential of the gas sensor array as a non-invasive diagnostic tool that enables real-time monitoring.


Nanoscale ◽  
2021 ◽  
Author(s):  
Carolina del Real Mata ◽  
Roozbeh Siavash Moakhar ◽  
Sayed Iman Isaac Hosseini ◽  
Mahsa Jalali ◽  
Sara Mahshid

Non-invasive liquid biopsies offer hope for a rapid, risk-free, real-time glimpse into cancer diagnostics. Recently, hydrogen peroxide (H2O2) is identified as a cancer biomarker due to continued release from cancer...


Lab on a Chip ◽  
2017 ◽  
Vol 17 (24) ◽  
pp. 4294-4302 ◽  
Author(s):  
Franziska D. Zitzmann ◽  
Heinz-Georg Jahnke ◽  
Felix Nitschke ◽  
Annette G. Beck-Sickinger ◽  
Bernd Abel ◽  
...  

We present a FEM simulation based step-by-step development of a microelectrode array integrated into a microfluidic chip for the non-invasive real-time monitoring of living cells.


2021 ◽  
Vol 11 (5) ◽  
pp. 385
Author(s):  
Cecilia Napodano ◽  
Cinzia Callà ◽  
Antonella Fiorita ◽  
Mariapaola Marino ◽  
Eleonora Taddei ◽  
...  

The ongoing outbreak of coronavirus disease 2019 (COVID-19), which impairs the functionality of several organs, represents a major threat to human health. One of the hardest challenges in the fight against COVID-19 is the development of wide-scale, effective, and rapid laboratory tests to control disease severity, progression, and possible sudden worsening. Monitoring patients in real-time is highly demanded in this pandemic era when physicians need reliable and quantitative tools to prioritize patients’ access to intensive care departments. In this regard, salivary biomarkers are extremely promising, as they allow for the fast and non-invasive collection of specimens and can be repeated multiple times. Methods: We compare salivary levels of immunoglobulin A subclasses (IgA1 and IgA2) and free light chains (kFLC and λFLC) in a cohort of 29 SARS-CoV-2 patients and 21 healthy subjects. Results: We found that each biomarker differs significantly between the two groups, with p-values ranging from 10−8 to 10−4. A Receiving Operator Curve analysis shows that λFLC level is the best-suited candidate to discriminate the two groups (AUC = 0.96), with an accuracy of 0.94 (0.87–1.00 95% CI), a precision of 0.91 (0.81–1.00 95% CI), a sensitivity of 1.00 (0.96–1.00 95% CI), and a specificity of 0.86 (0.70–1.00 95% CI). Conclusion: These results suggest λFLC as an ideal indicator of patient conditions. This hypothesis is strengthened by the consideration that the λFLC half-life (approximately 6 h) is significantly shorter than the IgA one (21 days), thus confirming the potential of λFLC for effectively monitoring patients’ fluctuation in real-time.


Sign in / Sign up

Export Citation Format

Share Document