scholarly journals Comparison of Biodegradation of Fats and Oils by Activated Sludge on Experimental and Real Scales

Water ◽  
2019 ◽  
Vol 11 (6) ◽  
pp. 1286 ◽  
Author(s):  
Pedro Cisterna-Osorio ◽  
Patricia Arancibia-Avila

Fats and oils are the most common pollutants in wastewater, and are usually eliminated through physical processes in wastewater treatment plants, generating large amounts of fats and residual oils that are difficult to dispose of and handle. The degradation of fatty wastewater was studied in a real wastewater treatment plant and a laboratory scale treatment unit. The wastewater treatment plant, located in Chile, was designed for a population of 200,000 inhabitants. It includes an aerobic digester that receives fat and oils retained in a degreaser and treats the fats and oils together with biomass. The biodegradation of fats and oils was analyzed in both wastewater treatment systems. Key parameters were monitored such as the concentration of fats and oils in the influents and effluents, mass loading, and the efficiency of biodegradation. The mass loading range was similar in both wastewater treatment systems. In the experimental activated sludge plant, the biodegradation of fats and oils reached levels in the range of 64% to 75%. For the wastewater treatment plant with an aerobic digester, the levels of biodegradation of fats and oils ranged from 69% to 92%. Therefore, considering the efficiency of the elimination of fats and oils, the results indicated that physical treatment should be replaced with biological treatment so that the CO2 generated by the biodegradation will be incorporated into the carbon cycle and the mass of fats and oils in landfills will be reduced.

2021 ◽  
Author(s):  
Pedro Eulogio Cisterna Osorio ◽  
Barbara Faundez-Miño

Fats and oils present in wastewater are usually eliminated by physical and biological processes. In this experience, the fatty wastewaters are treated biologically, and it assesses the impact of the mix in the fats and oils biodegradation and carried out the experiments in a laboratory scale unit. The biodegradation of fats and oils was analysed in two sceneries, with mix previous by mechanical agitation and without mix. Key parameters were monitored, such as the concentration of fats and oils in the influents and effluents, mass loading, and the efficiency of biodegradation. The mass loading range was similar in both sceneries. In the experimental activated sludge plant without mix, the biodegradation of fats and oils reached levels in the range of 28 to 42.5%. For the wastewater treatment plant with a previous mix by mechanical agitation, the levels of biodegradation of fats and oils ranged from 64 to 75%. Therefore, considering the efficiency of the biodegradation of fats and oils in both sceneries, the results indicated that the level mix is a high incidence.


2020 ◽  
Vol 12 (9) ◽  
pp. 1461
Author(s):  
Jorge Sancho Martínez ◽  
Yadira Bajón Fernández ◽  
Paul Leinster ◽  
Mónica Rivas Casado

Wastewater treatment plants are essential for preserving the water quality of freshwater and marine ecosystems. It is estimated that, in the UK, as much as 11 billion liters of wastewater are treated on a daily basis. Effective and efficient treatment of wastewater requires treatment plants to be maintained in good condition. Recent studies have highlighted the potential of unmanned aircraft systems (UASs) and image processing to be used in autonomous and automated monitoring systems. However, the combined use of UASs and image processing for wastewater treatment plant inspections has not yet been tested. This paper presents a novel image processing-UAS framework for the identification of failures in trickling filters and activated sludge facilities. The results show that the proposed framework has an accuracy of 95% in the detection of failures in activated sludge assets, with the accuracy ranging between 55% and 81% for trickling filters. These results are promising and they highlight the potential use of the technology for the inspection of wastewater treatment plants.


1992 ◽  
Vol 26 (5-6) ◽  
pp. 1315-1323 ◽  
Author(s):  
H. Aspegren ◽  
B. Andersson ◽  
U. Nyberg ◽  
J. la C. Jansen

Optimization of wastewater treatment plants with extensive phosphorus and nitrogen removal is complicated. The Klagshamn wastewater treatment plant in Sweden is operated with pre-precipitation of phosphorus with ferric chloride and denitrification with methanol as carbon source. An activated sludge process, operated with pre-precipitation and denitrification with external carbon source in a compartmentalized plant, requires only small tank volumes but increases the need for proper operation and optimization. On-line nitrogen, ammonia, and TOC sensors are used for a day-to-day control and optimization while mathematical modelling is used for long term strategic planning. The on-line measurements are further used as the basis for the modelling. TOC and ammonia sensors at the influent clearly identify typical and extreme loading variations and nitrate measurements in the activated sludge tanks and the effluent shows the dynamics of the processes. These measurements provide a basis for model calibration. In combination low residuals of nitrogen, phosphorus and organic matter can be achieved.


1999 ◽  
Vol 39 (2) ◽  
pp. 145-150
Author(s):  
T. Dormoy ◽  
B. Tisserand ◽  
L. Herremans

The new regulations require an increased amount of treatment of stormwater and a reduction of pollution loads discharged into the natural surroundings to be considered. Drainage systems therefore and particularly wastewater treatment plants should be sized correctly to cope with these peaks. Using a simulation software of wastewater treatment plant with activated sludge, such as SIMBAD, enables us to check that planned structures are appropriate in relation to the effluent quality requirements laid down, and to fix the most appropriate operating procedures. Operating constraints on a plant for treating stormwater are not negligible. It is advisable to allow for increased sludge production, O2 requirements and also sludge quality (fermentability).


2014 ◽  
Vol 69 (5) ◽  
pp. 1074-1079 ◽  
Author(s):  
Kris De Gussem ◽  
Alessio Fenu ◽  
Tom Wambecq ◽  
Marjoleine Weemaes

This work provides a case study on how activated sludge modelling and computational fluid dynamics (CFD) can help to optimize the energy consumption of a treatment plant that is already equipped with an advanced control based on online nutrient measurements. Currently, aeration basins on wastewater treatment plant Antwerp-South are operated sequentially while flow direction and point of inflow and outflow vary as a function of time. Activated sludge modelling shows that switching from the existing alternating flow based control to a simultaneous parallel feeding of all aeration tanks saves 1.3% energy. CFD calculations also illustrate that the water velocity is still sufficient if some impellers in the aeration basins are shutdown. The simulations of the Activated Sludge Model No. 2d indicate that the coupling of the aeration control with the impeller control, and automatically switching off some impellers when the aeration is inactive, can save 2.2 to 3.3% of energy without affecting the nutrient removal efficiency. On the other hand, all impellers are needed when the aeration is active to distribute the oxygen.


2006 ◽  
Vol 72 (8) ◽  
pp. 5643-5647 ◽  
Author(s):  
Hee-Deung Park ◽  
George F. Wells ◽  
Hyokwan Bae ◽  
Craig S. Criddle ◽  
Christopher A. Francis

ABSTRACT We report molecular evidence that ammonia-oxidizing archaea (AOA) occur in activated sludge bioreactors used to remove ammonia from wastewater. Using PCR primers targeting archaeal ammonia monooxygenase subunit A (amoA) genes, we retrieved and compared 75 sequences from five wastewater treatment plants operating with low dissolved oxygen levels and long retention times. All of these sequences showed similarity to sequences previously found in soil and sediments, and they were distributed primarily in four major phylogenetic clusters. One of these clusters contained virtually identical amoA sequences obtained from all five activated sludge samples (from Oregon, Wisconsin, Pennsylvania, and New Jersey) and accounted for 67% of all the sequences, suggesting that this AOA phylotype may be widespread in nitrifying bioreactors.


2017 ◽  
Vol 9 (4) ◽  
pp. 413-418
Author(s):  
Aušra Mažeikienė ◽  
Julita Starenko

It is important to control not only the large wastewater treatment plants work, but also the work of individual small wastewater treatment plants for the protection of environment. Individual small wastewater treatment plants can become the local sources of pollution, when they are not functioning properly. Sewage purification indicators are not always the same as declared at wastewater treatment plants documentation in real conditions, so it is important to control the properly work of individual small wastewater treatment plants. The work of the small wastewater treatment plant AT-6 was analyzed by the treated sewage results (BDS7, SM, NH4-N, NO3-N, NO2-N, PO4-P), the quality of activated sludge, biological indicators and enzymatic activity in this article. The nitrification process was not going very well by the results of research, because there was the 72 mg/l concentration of ammonium nitrogen remaining in the cleaned wastewater. The morphological study of the activated sludge has confirmed the hypothesis that the necessary conditions for nitrification process were not established. The oxygen supply was increased and the small wastewater treatment plant functioning become more efficient, because nitrification process started working properly – there was less than 1 mg/l of ammonium nitrogen remaining in the cleaned wastewater.


Processes ◽  
2020 ◽  
Vol 8 (5) ◽  
pp. 598 ◽  
Author(s):  
Tomáš Vítěz ◽  
Monika Vítězová ◽  
Markéta Nováčková ◽  
Ivan Kushkevych

Ensuring high quality drinking water sources is important task nowadays. To reach this task, knowledge about the impact of different chemicals on aerobic wastewater treatment is mandatory. A mixture of different chemicals reaches wastewater treatment plant every day. With the growing discharge volume of mobile toilet chemicals, active substances in these products in the past years have been recorded. The respiratory activity of activated sludge was determined to show how mobile toilet chemicals and their active substances may affect the biological wastewater treatment process. The results show negative effect of formaldehyde and bronopol on respiratory activity of activated sludge. The wastewater treatment plants influent composition and size also play important roles. Results shows that activated sludge microorganisms at a wastewater treatment plant in industrial urban area may be adapted to the higher pollutants concentration. When mobile toilet tanks are directly discharged at smaller wastewater treatment plant, an activated sludge process can be affected. For treating mobile toilet wastewater, bacterial degraders can be used. During our respiratory activity experiments, potential degraders were searched. Ralstonia sp. prevails in all samples and it is therefore a potential mobile toilet chemicals degrader.


2013 ◽  
Vol 1 (1) ◽  
pp. 1-13
Author(s):  
Riyadh M. S. Al-Obaidi

The biological unit in the wastewater treatment plants can be considered the most sensitive treatment units. It begins work with dynamic conditions for several weeks until reach the steady state conditions. Therefore, this study was done to observe aeration tank behavior (activated sludge unit) in the wastewater treatment plant of general hospital complex of Mosul city. Sampling made daily for more than 30 days. The biological treatment monitoring parameter was tested. The study shown that there is need to about 45-60 days to complete the start up work to be the operation stable and successful (if it worked without seeding). There was simple growth of microorganisms with modest treatment of organic matter, and then it rose after 3 first weeks of operation. There was contrary relationship between organic content and suspended solids in the aeration tank; an equation of this relation has been presented. The pH has risen in the first days in the effluent wastewater, then return to be less than influent pH with a relative relation with the activity of the microorganisms and surface aeration in the tank. The EC was simply reduced in the Effluent along with the study.


2012 ◽  
Vol 65 (9) ◽  
pp. 1654-1659 ◽  
Author(s):  
S. Lyko ◽  
B. Teichgräber ◽  
A. Kraft

Sludge bulking is still a problem in the operation of state-of-the-art wastewater treatment plants (WWTPs). The ozonation of returned activated sludge (RAS) is an innovative option as a non-specific measure for the control of filament growth. The applicability of sludge ozonation for bulking control of a large wastewater treatment plant was investigated. At a full-scale WWTP one lane was equipped with a sludge ozonation plant for RAS. The implemented sludge ozonation of RAS was tested against the two identical references lanes of the same WWTP. The positive effect on settleability could be clearly proven. Low-dose sludge ozonation could be a technical alternative in comparison with the established chemical measures for bulking control.


Sign in / Sign up

Export Citation Format

Share Document