scholarly journals Come eseguire lo studio cardiaco T2 star pesata di risonanza magnetica per gli accumuli di ferro nella talassemia

2020 ◽  
pp. 36-39
Author(s):  
Martini Alberto ◽  
Morelli Giovanni ◽  
Nappa Elena ◽  
Notorio Maurizio

The aim of the study is to show how to execute a cardiac T2* MRI assessment correctly in patients who suffer from iron overload in vital organs, particularly in the heart. The main cause of iron overload is Thalassemia, the disease which is widely spread in the Southern and Middle part of Italy, as well as the Mediterranean coast. Researchers have demonstrated that patients who suffer from thalassemia might have an excessive and toxic iron overload which could lead to heart failure and death. Thanks to the T2*single breath-hold multi-echoes sequence, using a dedicated software, the patients’ myocardial iron deposition can be classified into three groups: T2* MRI < 10 ms ( high risk group) T2* MRI =10-20 ms ( medium-risk group) T2* MRI > 20 ms (low-risk group) This measure called “saturation time”(expressed in 1/1000 sec.), also allows physicians to customize medical treatment for every patient, same as a good tailor does to make a new dress fits well on every single client. However, to obtain precise and reliable results, radiographers first and radiologists afterwards, must respect every single technical parameter in MR techniques

Blood ◽  
2007 ◽  
Vol 110 (11) ◽  
pp. 2771-2771
Author(s):  
Wing Y. Au ◽  
Wynnie Lam ◽  
Winnie Chu ◽  
Hui-leung Yuen ◽  
S.C. Ling ◽  
...  

Abstract Background: The use of magnetic resonance imaging (MRI) for organ specific iron assessment has allowed better tailoring of chelation therapy. Since endocrine failure is common in thalassemia major (TM) patients, we explored the utility of rapid T2* MRI assessment of hemosiderosis in the pancreas and pituitary. The results were correlated with standard T2* heart and liver MRI assessments and clinical data. Material and methods: A total of 180 TM patients (M:F = 91:89, median age, range 12–48) were scanned on a 1.5 T scanner. (Sonata, Siemens Medical, Erlanger, Germany). T2* myocardium was assessed by a cardiac gated single breath hold 8-echo sequence (CMRtools; London, UK). The T2* liver, pancreas and pituitary were performed by a breath hold 20-echo sequence. Subcutaneous deferoxamine was used for chelation, except for addition of deferiprone in 24 cases for 1 year. Results: There was a high incidence of hemosiderosis of heart (severe T2*<12ms: 34%, mild-moderate <20ms, 15%) and liver (severe T2*<1.4ms, 14% mild-moderate <6.3ms, 63%). Iron overload above normal control was commonly found in the pancreas (T2*<23ms, 84%) and pituitary (T2*<5.9ms, 24%). Pancreatic T2* correlated with pituitary T2* (p=0.007, r=0.2), cardiac T2*(p<0.001, r=0.33), liver T2* (p<0.001, r=0.35), ferritin (p=0.004, r=−0.19) and age (p=0.033, r=0.16). Similarly pituitary T2* related to cardiac T2* (p<0.001, r=0.36) and liver T2* (p=0.026, r=0.17). On multivariate analysis, however, pancreatic T2* related to both heart T2* (p<0.001) and liver T2* (p=0.001), while pituitary T2* only related to heart T2* (p<0.001). Documented complications amongst the cases included heart failure (ejection fraction EF<55%, n=28, 16%), hypogonadism (n=84,47%), diabetes mellitus (n=44, 25%), hypoparathyroidism (n=16, 9%) and hypothyroidism (n=36, 20%), with hepatitis B and C carrier state in 2% and 25% respectively. On univariate and multivariate analysis, all 4 endocrine failures correlated with only cardiac T2* results (all p<0.001) and age (all p<0.001), but not with pituitary or pancreatic T2* results. The EF correlated with T2* of pituitary, pancreas and heart, but only MRI heart T2* correlation remained significant on multivariate analysis. Conclusions: MRI pituitary and pancreatic evaluation is viable in a cohort of poorly chelated Chinese thalassemia major patients on subcutaneous deferoxamine treatment. However, an abnormal cardiac T2* result is a good surrogate for endocrine iron overload and appeared more relevant in predicting endocrine complications.


Blood ◽  
2010 ◽  
Vol 116 (21) ◽  
pp. 5169-5169
Author(s):  
Antonella Meloni ◽  
incenzo Positano ◽  
Alessia Pepe ◽  
Dell'Amico Maria Chiara ◽  
Luca Menichetti ◽  
...  

Abstract Abstract 5169 Introduction. T2* multiecho cardiovascular magnetic resonance (CMR) is largely used to assess iron overload in heart because of the established inverse relationship between the T2* value and the iron concentration in tissues (Wood JC et al, Hemoglobin 2008). The decay of CMR signal is sampled at several echo times (TEs) and the T2* is inferred by fitting the decay curve to an appropriate model (Positano V et al, NMR in Biomed 2007). Our aim was to quantify the reliance on TEs of the expected error in T2* value determination. Methods. The Cramer-Rao lower bounds theory (CRLB) was used. CRLB provide a fundamental limit to the accuracy in determination of the T2* value from experimental data in dependence of SNR at signal samples. CRLB were evaluated for a commonly used multi-echo sequence with the first TE equal to the minimum achievable (1.4-2 ms), ΔTE of about 2.3 ms to minimize the fat-water interface artifacts, 10 echoes to assure acquisition in a single breath-hold. Results. Percent error in T2* values assessment was lower than 10% in the range of clinical interest, with the exception of very low T2* values. Precision in measurement of low T2* values is strongly dependent on the value of the first TE, that is limited by the used scanner. T2* values greater than 1.8 ms and 1.5 ms can be assessed with an error below 20% using a first TE of 2 ms and 1.5 ms, respectively (see Figure). Conclusions. T2* multiecho sequences used in clinical practice assure an acceptable precision for T2* values ≥ 2 ms, depending from the used hardware. This limit includes almost all patients with hemochromatosis or hemosiderosis in country where the patients can be well managed. For patients with very high myocardial iron overload sequences with lower minimum echo time and/or lower echoes interval may be useful. Disclosures: No relevant conflicts of interest to declare.


1993 ◽  
Vol 3 (4) ◽  
pp. 611-616 ◽  
Author(s):  
Thomas K. F. Foo ◽  
James R. Macfall ◽  
H. Dirk Sostman ◽  
Cecil E. Hayes

2017 ◽  
Vol 79 (2) ◽  
pp. 815-825 ◽  
Author(s):  
Xiufeng Li ◽  
Edward J. Auerbach ◽  
Pierre-Francois Van de Moortele ◽  
Kamil Ugurbil ◽  
Gregory J. Metzger

1975 ◽  
Vol 38 (5) ◽  
pp. 768-773 ◽  
Author(s):  
N. N. Stanley ◽  
M. D. Altose ◽  
S. G. Kelsen ◽  
C. F. Ward ◽  
N. S. Cherniack

Experiments were conducted on human subjects to study the effect of lung inflation during breath holding on respiratory drive. Two series of experiments were performed: the first to examine respiratory drive during a single breath hold, the second designed to examine the sustained effect of lung inflation on subsequent breath holds. The experiments involved breath holding begun either at the end of a normal expiration or after a maximum inspiration. When breath holding was repeated at 10-min intervals, the increase in BHT produced by lung inflation was greater in short breath holds (after CO2 rebreathing) than in long breath holds (after hyperventilation). If breath holds were made in rapid succession, the first breath hold was much longer when made at total lung capacity than at functional residual capacity, but this effect of lung inflation diminished in subsequent breath holds. It is concluded that the inhibitory effect of lung inflation decays during breath holding and is regained remarkably slowly during the period of breathing immediately after breath holding.


2018 ◽  
Vol 31 (6) ◽  
pp. e3923 ◽  
Author(s):  
Yong Chen ◽  
Wei-Ching Lo ◽  
Jesse I. Hamilton ◽  
Kestutis Barkauskas ◽  
Haris Saybasili ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document