Thermal drift of frequency difference of frequency splitting laser with force-exerting

2021 ◽  
Vol 50 (2) ◽  
pp. 20200392-20200392
Author(s):  
王琦 Qi Wang ◽  
钱永明 Yongming Qian ◽  
张书练 Shulian Zhang
2021 ◽  
Vol 50 (2) ◽  
pp. 20200392-20200392
Author(s):  
王琦 Qi Wang ◽  
钱永明 Yongming Qian ◽  
张书练 Shulian Zhang

Author(s):  
Louis T. Germinario

A liquid nitrogen stage has been developed for the JEOL JEM-100B electron microscope equipped with a scanning attachment. The design is a modification of the standard JEM-100B SEM specimen holder with specimen cooling to any temperatures In the range ~ 55°K to room temperature. Since the specimen plane is maintained at the ‘high resolution’ focal position of the objective lens and ‘bumping’ and thermal drift la minimized by supercooling the liquid nitrogen, the high resolution capability of the microscope is maintained (Fig.4).


Author(s):  
P.R. Swann ◽  
A.E. Lloyd

Figure 1 shows the design of a specimen stage used for the in situ observation of phase transformations in the temperature range between ambient and −160°C. The design has the following features a high degree of specimen stability during tilting linear tilt actuation about two orthogonal axes for accurate control of tilt angle read-out high angle tilt range for stereo work and habit plane determination simple, robust construction temperature control of better than ±0.5°C minimum thermal drift and transmission of vibration from the cooling system.


2020 ◽  
pp. 35-38
Author(s):  
S.I. Donchenko ◽  
I.Y. Blinov ◽  
I.B. Norets ◽  
Y.F. Smirnov ◽  
A.A. Belyaev ◽  
...  

The latest changes in the algorithm for the formation of the international atomic time scale TAI are reported in terms of estimating the weights of the clocks involved in the formation of TAI. Studies of the characteristics of the long-term instability of new-generation hydrogen masers based on processing the results of the clock frequency difference with respect to TAI are performed. It has been confirmed that at present, new-generation hydrogen masers show significantly less long-term instability in comparison with quantum frequency standards ofsimilar and other types.


Proceedings ◽  
2021 ◽  
Vol 68 (1) ◽  
pp. 13
Author(s):  
Yixuan Sun ◽  
Stephen Beeby

This paper presents the COMSOL simulations of magnetically coupled resonant wireless power transfer (WPT), using simplified coil models for embroidered planar two-coil and four-coil systems. The power transmission of both systems is studied and compared by varying the separation, rotation angle and misalignment distance at resonance (5 MHz). The frequency splitting occurs at short separations from both the two-coil and four-coil systems, resulting in lower power transmission. Therefore, the systems are driven from 4 MHz to 6 MHz to analyze the impact of frequency splitting at close separations. The results show that both systems had a peak efficiency over 90% after tuning to the proper frequency to overcome the frequency splitting phenomenon at close separations below 10 cm. The four-coil design achieved higher power efficiency at separations over 10 cm. The power efficiency of both systems decreased linearly when the axial misalignment was over 4 cm or the misalignment angle between receiver and transmitter was over 45 degrees.


Symmetry ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1357
Author(s):  
Linxiao Cong ◽  
Jianchao Mu ◽  
Qian Liu ◽  
Hao Wang ◽  
Linlin Wang ◽  
...  

The space gravitational wave detection and drag free control requires the micro-thruster to have ultra-low thrust noise within 0.1 mHz–0.1 Hz, which brings a great challenge to calibration on the ground because it is impossible to shield any spurious couplings due to the asymmetry of torsion balance. Most thrusters dissipate heat during the test, making the rotation axis tilt and components undergo thermal drift, which is hysteretic and asymmetric for micro-Newton thrust measurement. With reference to LISA’s research and coming up with ideas inspired from proportional-integral-derivative (PID) control and multi-timescale (MTS), this paper proposes to expand the state space of temperature to be applied on the thrust prediction based on fine tree regression (FTR) and to subtract the thermal noise filtered by transfer function fitted with z-domain vector fitting (ZDVF). The results show that thrust variation of diurnal asymmetry in temperature is decoupled from 24 μN/Hz1/2 to 4.9 μN/Hz1/2 at 0.11 mHz. Additionally, 1 μN square wave modulation of electrostatic force is extracted from the ambiguous thermal drift background of positive temperature coefficient (PTC) heater. The PID-FTR validation is performed with experimental data in thermal noise decoupling, which can guide the design of thermal control and be extended to other physical quantities for noise decoupling.


Sign in / Sign up

Export Citation Format

Share Document