scholarly journals Preliminary project design for insect production: part 2 – organism kinetics, system dynamics and the role of modelling & simulation

2021 ◽  
pp. 1-14
Author(s):  
R. Kok

During preliminary project design (PPD) an entopreneur can investigate a variety of process types, organism/feed combinations, operating conditions and procedures, control approaches, etc. before deciding on a specific system arrangement and proceeding to a more formal design stage. With modelling and simulation the effort required to locate a high-value point within the overall possibility space for a system can be greatly reduced because much of the development work can be carried out in a virtual environment. Nevertheless, to formulate models of the organism/feed kinetics as well as other system aspects, this approach must be based on experimental data. And, of course, results of a simulation study must be verified empirically. A simulation-based approach to PPD allows an entopreneur to study the dynamics of a wide variety of system arrangements and to gain insight into how a given arrangement is likely to perform with different parameter values and disturbances.

2009 ◽  
Vol 136 (1) ◽  
pp. 60-68
Author(s):  
Andrzej BALCERSKI ◽  
Cezary BEHRENDT ◽  
Zbigniew KNEBA

The original concept of the energy test during continuous fishing of a Baltic cutter lasting 100 working days at the fishery has been presented in the paper. The test will enable the calculation of the fuel consumption and the operating efficiency of the energy system. The calculation models which are made in the paper take into account the actual realizations of energy and trawling systems, operating conditions of ships and parameter values characterizing the operation of all devices under consideration. The test may be used to evaluate the design solutions of ships at the design stage as well as the ones already in use.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Haim Kalman

AbstractAny scientific behavior is best represented by nondimensional numbers. However, in many cases, for pneumatic conveying systems, dimensional equations are developed and used. In some cases, many of the nondimensional equations include Reynolds (Re) and Froude (Fr) numbers; they are usually defined for a limited range of materials and operating conditions. This study demonstrates that most of the relevant flow types, whether in horizontal or vertical pipes, can be better described by Re and Archimedes (Ar) numbers. Ar can also be used in hydraulic conveying systems. This paper presents many threshold velocities that are accurately defined by Re as a simple power function of Ar. Many particulate materials are considered by Ar, thereby linking them to a common behavior. Using various threshold velocities, a flow regime chart for horizontal conveying is presented in this paper.


Author(s):  
Nishesh Jain ◽  
Esfand Burman ◽  
Dejan Mumovic ◽  
Mike Davies

To manage the concerns regarding the energy performance gap in buildings, a structured and longitudinal performance assessment of buildings, covering design through to operation, is necessary. Modelling can form an integral part of this process by ensuring that a good practice design stage modelling is followed by an ongoing evaluation of operational stage performance using a robust calibration protocol. In this paper, we demonstrate, via a case study of an office building, how a good practice design stage model can be fine-tuned for operational stage using a new framework that helps validate the causes for deviations of actual performance from design intents. This paper maps the modelling based process of tracking building performance from design to operation, identifying the various types of performance gaps. Further, during the operational stage, the framework provides a systematic way to separate the effect of (i) operating conditions that are driven by the building’s actual function and occupancy as compared with the design assumptions, and (ii) the effect of potential technical issues that cause underperformance. As the identification of issues is based on energy modelling, the process requires use of advanced and well-documented simulation tools. The paper concludes with providing an outline of the software platform requirements needed to generate robust design models and their calibration for operational performance assessments. Practical application The paper’s findings are a useful guide for building industry professionals to manage the performance gap with appropriate accuracy through a robust methodology in an easy to use workflow. The methodological framework to analyse building energy performance in-use links best practice design stage modelling guidance with a robust operational stage investigation. It helps designers, contractors, building managers and other stakeholders with an understanding of procedures to follow to undertake an effective measurement and verification exercise.


Author(s):  
Men Wirz ◽  
Matthew Roesle ◽  
Aldo Steinfeld

Thermal efficiencies of the solar field of two different parabolic trough concentrator (PTC) systems are evaluated for a variety of operating conditions and geographical locations, using a detailed 3D heat transfer model. Results calculated at specific design points are compared to yearly average efficiencies determined using measured direct normal solar irradiance (DNI) data as well as an empirical correlation for DNI. It is shown that the most common choices of operating conditions at which solar field performance is evaluated, such as the equinox or the summer solstice, are inadequate for predicting the yearly average efficiency of the solar field. For a specific system and location, the different design point efficiencies vary significantly and differ by as much as 11.5% from the actual yearly average values. An alternative simple method is presented of determining a representative operating condition for solar fields through weighted averages of the incident solar radiation. For all tested PTC systems and locations, the efficiency of the solar field at the representative operating condition lies within 0.3% of the yearly average efficiency. Thus, with this procedure, it is possible to accurately predict year-round performance of PTC systems using a single design point, while saving computational effort. The importance of the design point is illustrated by an optimization study of the absorber tube diameter, where different choices of operating conditions result in different predicted optimum absorber diameters.


Author(s):  
Brittany Goldsmith ◽  
Elizabeth Foyt ◽  
Madhu Hariharan

As offshore field developments move into deeper water, one of the greatest challenges is in designing riser systems capable of overcoming the added risks of more severe environments, complicated well requirements and uncertainty of operating conditions. The failure of a primary riser component could lead to unacceptable consequences, including environmental damage, lost production and possible injury or loss of human life. Identification of the risks facing riser systems and management of these risks are essential to ensure that riser systems operate without failure. Operators have recognized the importance of installing instrumentation such as global positioning systems (GPS), vessel motion measurement packages, wind and wave sensors and Acoustic Doppler Current Profiler (ADCP) units to monitor vessel motions and environmental conditions. Additionally, high precision monitoring equipment has been developed for capturing riser response. Measured data from these instruments allow an operator to determine when the limits of acceptable response, predicted by analysis or determined by physical limitations of the riser components, have been exceeded. Regular processing of measured data through automated routines ensures that integrity can be quickly assessed. This is particularly important following extreme events, such as a hurricane or loop current. High and medium alert levels are set for each parameter, based on design analysis and operating data. Measured data is compared with these alert levels, and when an alert level is reached, further response evaluation or inspection of the components in question is recommended. This paper will describe the role of offshore monitoring in an integrity management program and discuss the development of alert levels based on potential failure modes of the riser systems. The paper will further demonstrate how this process is key for an effective integrity management program for deepwater riser systems.


1996 ◽  
Vol 19 (4) ◽  
pp. 677-714 ◽  
Author(s):  
Samuel David Epstein ◽  
Suzanne Flynn ◽  
Gita Martohardjono

AbstractTo what extent, if any, does Universal Grammar (UG) constrain second language (L2) acquisition? This is not only an empirical question, but one which is currently investigable. In this context, L2 acquisition is emerging as an important new domain of psycholinguistic research. Three logical possibilities have been articulated regarding the role of UG in L2 acquisition: The first is the “no access” hypothesis that claims that no aspect of UG is available to the L2 learner. The second is the “partial access” hypothesis that claims that only LI instantiated principles and LI instantiated parameter-values of UG are available to the learner. The third, called the “full access” hypothesis, asserts that UG in its entirety constrains L2 acquisition.In this paper we argue that there is no compelling evidence to support either of the first two hypotheses. Moreover, we provide evidence concerning functional categories in L2 acquisition consistent with the claim that UG is fully available to the L2 learner (see also Flynn 1987; Li 1993; Martohardjono 1992; Schwartz & Sprouse 1991; Thomas 1991; White 1989). In addition, we will attempt to clarify some of currently unclear theoretical issues that arise with respect to positing UG as an explanatory theory of L2 acquisition. We will also investigate in some detail certain crucial methodological questions involved in experimentally testing the role of UG in L2 acquisition and finally, we will present a set of experimental results of our own supporting the “Full Access” hypothesis.


2010 ◽  
Vol 10 (2) ◽  
pp. 165-172 ◽  
Author(s):  
K. Diao ◽  
M. Barjenbruch ◽  
U. Bracklow

This paper aims to explore the impacts of peaking factors on a water distribution system designed for a small city in Germany through model-based analysis. As a case study, the water distribution network was modelled by EPANET and then two specific studies were carried out. The first study tested corresponding system-wide influences on water age and energy consumption if the peaking factors used at design stage are inconsistent with ones in real situation. The second study inspected the possible relationship between the choice of peaking factors and budgets by comparing several different pipe configurations of the distribution system, obtained according to variety of peaking factors. Given the analysis results, the first study reveals that average water age will increase if peaking factors estimated at design stage are larger than real values in that specific system, and vice versa. In contrast, energy consumption will increase if peaking factors defined for system design are smaller than ones in real case, and vice versa. According to the second study, it might be possible to amplify peaking factors for design dramatically by a slight increase in the investment on this system. However, further study on budget estimation with more factors and detailed information considered should be carried out.


2021 ◽  
Author(s):  
Charles Okafor ◽  
Patrick Verdin ◽  
Phill Hart

Abstract Downhole Natural Gas Separation Efficiency (NGSE) is flow regime dependent, and current analytical models in certain conditions lack accuracy. Downhole NGSE was investigated through 3D Computational Fluid Dynamics (CFD) transient simulations for pumping wells in the Churn flow regime. The Volume of Fluid (VOF) multiphase model was considered along with the k – ε turbulence model for most simulations. A mesh independence study was performed, and the final model results validated against experimental data, showing an average error of less than 6 %. Numerical simulation results showed that the steady state assumption used by current mathematical models for churn flow can be inaccurate. Several key parameters affecting the NGSE were identified, and suggestions for key improvements to the widely used mathematical formulations for viscous flow provided. Sensitivity studies were conducted on fluid/geometric parameters and operating conditions, to gain a better understanding of the influence of each parameter on NGSE. These are important results as they equip the ESP engineer with additional knowledge to maximise the NGSE from design stage to pumping operations.


Sign in / Sign up

Export Citation Format

Share Document